background image

11

•  Following  a  prolonged  period  (more  than  a  month)  during 
which the system has not been in operation or produced wa-
ter, contact your distributer in order to carry out the proper 
hygienisation and maintenance. 
• In order to improve the performance of the system, extract 
full jugs and bottles and avoid the occasional extraction of 
glasses. 
• Special attention must be paid to the regular cleaning and 
hygiene of the faucet of the reverse osmosis system, and 
especially during the periodic maintenance. Use the Oxibac 
spray (Ref. 65220) for this and disposable kitchen paper or a 
multiuse cloth for cleaning the kitchen.

5.5  Recommendations for the correct use of the 

reverse osmosis water

•  If  you  want  to  feed  any  other  consumption  point  with  
osmosis water (such as a fridge with an ice-cube dispenser, 
another faucet, etc.), the piping should not be done with  
a metal tube, as this will give the water a bad taste. Use a 
similar plastic tube (Ref. 272000).

• The water supplied by the domestic reverse osmosis systems 
has a LOW SALT CONTENT. The mineral salts required by the 
human body are provided by food, especially by dairy products 
and to a lesser degree by the water we drink. 

5. Warnings

5.2  Installation of the system

•  Should  it  be  necessary  to  condition  the  installation  of  the 
home in order to install the system in the foreseen location, it 
must be carried out in accordance with the national legistation 
in face.
• The PROLINE PLUS PUMP series system needs an electrical 
socket that is at least 1 metre away.
• The location foreseen for its installation must have sufficient 
space for the machine itself, its accessories, connections, and 
to carry out maintenance comfortably.  
• Under no circumstances must the system be installed outdoor.
• The systems should not be installed next to a heat source or 
where it receives a direct flow of hot air (dryer, refrigerator, etc.)
•  The  surroundings  and  setting  where  the  system  and  tap 
are to be installed must meet appropriate hygiene-sanitary 
conditions.
• Avoid external drips from pipes, drains etc. onto the machinery.

5.3  Start-up and maintenance

•  The  PROLINE  PLUS  series  systems,  needs  to  undergo 
periodic maintenance carried out by qualified technical 

 

personnel, with the objective of guaranteeing the quality of the 
water produced and supplied.

•  The  consumable  elements  must  be  substituted  with  
the frequency indicated by the manufacturer (See section  
9. Maintenance).
• The system must be hygienised periodically and prior to its 
start up.
• Following the start up, the first two deposits must be thrown 
away. 
•  The  system  must  be  maintained  by  qualified  technical 
personnel, carried out under the proper hygienic condi-
tions, with the objective of reducing the risk of internal 
contamination of the machine and its hydraulic system. 
(For more information contact the technical service of your 
distributor).

5.4  Use of the system

• When you are going to be away from home for more than a 
week close the water inlet, empty it and disconnect the elec-
tric current. On your return connect the electric current of the 
same, open the inlet and empty the reservoir tank twice before 
consuming the water.

Summary of Contents for PROLINE PLUS

Page 1: ...INSTRUCTIONS MANUAL PROLINE PLUS PROLINE PLUS PUMP ...

Page 2: ...trol system for lower water consumption MANUAL FLUSHING VALVE Manual valve for the washing of the membrane SOLENOID VALVE With safety filter DIRECT ACCESS Easy maintenance INSERT Safety system in the pipe connections MANUAL FLUSHING VALVE Manual valve for the washing of the membrane DIRECT ACCESS Easy maintenance INSERT Safety system in the pipe connections ProlinePlus PUMP ...

Page 3: ...3 ...

Page 4: ...p Store tap Low pressure switch High pressure switch Granulated carbon post filter Membrane container 24 V electro valve with mesh filter UP7000 24 Vdc pump Metallic structure depending on model 5 μm sediment filter Activated granulated carbon cartridge GAC Activated granulated carbon cartridge BLOCK KEY a b c d e f g h i j k l m n DESCRIPTION 5 μm sediment filter Activated granulated carbon cartr...

Page 5: ...or the proper working of the system 05 2 Installation of the system 05 3 Operation and maintenance 05 4 Use of the system 05 5 Recommendations for the correct use of the reverse osmosis water 06 INSTALLATION OF THE SYSTEM 07 OPERATION OF THE PROLINE PLUS SYSTEMS 07 1 Description of Operation 08 MAINTENANCE AND CONSUMABLES 08 1 Maintenance 08 2 Hygienisation 08 3 Flushing 9 IDENTIFICATION GUIDE AND...

Page 6: ...ibuted by natural osmosis The human body is mainly made up of water Woman 55 65 Man 65 75 Child 80 An adult body contains between 38 and 48 litres of water 30 of which is found in the cells This water in the body which is almost completely recycled every 15 days is the basis for the transportation of nutrients oxygen to cells the elimination of waste and it controls the body temperature We consume...

Page 7: ...stances reduced by the reverse osmosis membrane The chemical composition and concentration of salts and other substances of the water on entering the reverse osmosis system has an affect on the purified water The TFC reverse osmosis membrane of your PROLINE PLUS Series system can reduce the concentration of the elements and compounds among others outlined in the following tables ELEMENT COMPOUND O...

Page 8: ... 20 5 80 BY PRESSURE ON PRODUCTION 0 70 0 25 0 33 0 42 0 58 1 00 1 08 1 17 1 25 1 42 REJECTION OF SALTS 84 88 90 92 93 95 95 95 95 CONVERSION FACTOR CONVERSION FACTOR BY TEMPERATURE TemperaturE ºC 6 8 10 12 14 16 18 20 22 25 28 30 32 34 ON PRODUCTION 0 38 0 45 0 52 0 59 0 66 0 70 0 77 0 85 0 88 1 00 1 09 1 16 1 23 1 30 The life of the membrane is evaluated by the percentage of salts rejected 90 95...

Page 9: ...PRODUCTION LPD 150 MEMBRANE Type 1 x 1812 50 MEMBRANE PRODUCTION 175 LPD Soft water with 250 ppm T 25 ºC Recovery 15 Pressure against membrane 3 4 bars without counter pressure PUMP Booster MAX ACCUMULATION pre charged tank at 7 PSI 19 litres ELECTRIC CURRENT 220 240 V 50 Hz 24 W ELECTRIC ADAPTOR 100 240 V 50 60 Hz 24 Vdc 1A MANUFACTURER Manufactured by Puricom Water Ind Corp Taiwan for PURICOM EU...

Page 10: ... higher than 2000 ppm contact your distributor It is recommended that you soften the water to be treated or that has a maximum hardness of 15 ºF with the objective of obtaining the optimum performance of the system Should the water to be treated have a level of hardness superior to 15 ºF the life of the membrane may be reduced and also the performance of the system It is recommended that you brush...

Page 11: ... electrical socket that is at least 1 metre away The location foreseen for its installation must have sufficient space for the machine itself its accessories connections and to carry out maintenance comfortably Under no circumstances must the system be installed outdoor The systems should not be installed next to a heat source or where it receives a direct flow of hot air dryer refrigerator etc Th...

Page 12: ... by qualified personnel from an authorised technical service Follow the recommendations in Section 5 of this manual Given that the appliance that you are going to install improves the quality of the water that you are going to consume and is considered a food all of the tools that you are going to use for the assembly and installation must be clean and under no circumstances contaminated or impreg...

Page 13: ...sembly due to the geometrics of the counter top or fridge use the rubber joint supplied instead of the metal escutcheon in order to assemble the tap Choose the bit and the type of drill that is appropriate for the material in question 2 Prior to this insert the metal escutcheon and a thick flat rubber joint into the connecting pipe these must be on the upper part of the counter top Then pass the t...

Page 14: ...s properly assembled and water tight Subsequently in the male connector of the 1 2 adapter connect the flexible pipe usually female Should it be necessary to install a special component it should not be iron or contain iron components as on rusting these can reduce the performance of the appliance To ensure the proper installation and water tightness of the connections made open the right angle en...

Page 15: ...pe collar shall be assembled but making sure that the hole that you have made is completely aligned over the front part of the 1 4 connector part where the square pad goes done by putting the bit used for making the 6 mm hole there through the hole there is between the clamp and the drainpipe thereby avoiding any obstacle to the passing of water towards the same Put the nuts in the socket on the b...

Page 16: ... te Ref 279300 for every extra pipe connection you need 11 Check that the pressure of the reservoir tank is 0 5 bars 7 P S I using the portable pressure gauge and the valve that is at the bottom of the tank If this is not the case fill or empty the pressurised tank until you achieve the indicated pressure Image 40 6 Installation of the system ...

Page 17: ...h manual wash valve Connection to the drain Check valve Manual valve of reservoir tank Pressurised reservoir tank Activated carbon post filter Counter top tap Low pressure switch Shut off electro valve Booster pump High pressure switch 7 OPERATION OF THE PROLINE PLUS SYSTEMS Electrical diagram of proline plus pump VALID LIST FOR PROLINE PLUS PUMP AND PROLINE PLUS PROLINE PLUS PUMP 24 Vdc MOTOR PUM...

Page 18: ...valve 15 when this situation is detected The wa ter pressure against the membrane makes the reverse osmosis process possible On the one hand the reverse osmosis water after going through a check valve 9 is stored in a reservoir tank 11 and on the other hand the water with excess salts and unwanted substances go to the drain 8 for their elimination through the flow limiter 7 When the reservoir tank...

Page 19: ...has not been consumed for more than a month MAINTENANCE RECOMMENDATIONS BY YOUR OFFICIAL PROLINE PLUS SERIES DISTRIBUTOR NOTE The membrane must be substituted if a specific compound is higher than the maximum advisable permitted limit for drinking water European directive 98 83 EC An excess of a compound total chlorine turbidity hardness etc can lead to a reduction in the life of the filters and c...

Page 20: ...cing the 1 4 exit tube Connect this tube using its 1 4 nut of the exit of the post filter 6 Extract the membrane from inside the membrane housing images 82 and 83 and apply the hygienisation procedure de scribed in section 7 Start up and hygienisation Use the membrane housing wrench to disassemble the top and the vice grip pliers to extract the interior membrane Images 84 and 85 7 Replace the filt...

Page 21: ...elements and they will be eliminated down the drain For this after the continuous extraction of more than 2 litres of water image 86 open the 15 cleaning valve manually and close it immediately afterwards Images 87 88 and 89 By this simple action you are able to prolong the life of your membrane 8 Maintenance and consumables 86 88 87 89 opened CLOSED ...

Page 22: ...on in the in let valve or substitute it They are tightened too close to the wall Do not have holding pins They are in bad condition substitute them or not pushed into connectors enough Wait until supply returns Check condition of coil and clean it Change it if necessary Change filter Change membrane Check condition of restrictor If blocked clean or substitute Clean or substitute Check supply in th...

Page 23: ...gm in bad condition Transformer in bad condition SOLUTION Check if rejection stops with the reverse osmosis system unplugged Should it not clean or substitute Put in a pressure regulator Check that there is 0 5 Kg cm2 or 7 PSI air pressure with an empty tank Substitute Check regulation and where applicable substitute Clean if dirty If in bad condition substitute it Substitute Repair product or sub...

Page 24: ...N COMPLETE MAINTENANCE REPAIR HYGIENISATION OTHERS COMPLETE MAINTENANCE REPAIR HYGIENISATION OTHERS COMPLETE MAINTENANCE REPAIR HYGIENISATION OTHERS COMPLETE MAINTENANCE REPAIR HYGIENISATION OTHERS COMPLETE MAINTENANCE REPAIR HYGIENISATION OTHERS COMPLETE MAINTENANCE REPAIR HYGIENISATION OTHERS ...

Page 25: ...outside specifications provided or in those cases where it has been modified or prepared by personnel that do not belong to the company or official The substituted parts under guarantee remain the property of PURICOM EUROPE The term of the guarantee starts on the date of purchase of the system in your PURICOM EUROPE Distributor For whatsoever claim under the guarantee you are required to provide r...

Page 26: ...py them him herself to the GUARANTEE CERTIFICATE SHEET The installer distributor must keep this sheet and Ionfilter may request it with the objective of improving the post sales service and customer service to the client The technician carrying out the installation and putting the equipment into operation must have the appropriate technical capacity S O P N S N INFORMATION CONCERNING THE APPLICATI...

Page 27: ...27 ...

Page 28: ...allès Barcelona SPAIN puricom puricom eu www puricom eu Ref 584701 Manual de instrucciones PROLINE PLUS 2014 The quality system of Puricom Europe for the marketing and assembly of water treatment equipment and in accordance with regulation UNE EN ISO 9001 2000 8 435291 802972 ...

Reviews: