background image

8

Wire Gauge

Maximum 

Cable Length 

(ft)

6

6

4

10

2

16

1

20

1/0

25

2/0

32

3/0

40

4/0

51

Wire Gauge

Maximum 

Cable Length 

(ft)

6

8

4

13

2

21

1

27

1/0

34

2/0

43

3/0

54

4/0

68

Installation Complete

Note: The inverter controller cable can be CAT5, CAT5e, or CAT6 and must 

have male RJ45 connectors on both ends (shielded or unshielded are both 

okay). The cable must be 8 position and 8 conductor (8p8c) and it cannot 

be a cross-over cable. Most RJ45/Ethernet type cables will work as long as 

the conductors are 24 gauge or larger.

We recommend :

•  the conductors in the cable be 24 gauge or larger
•  the cable be 16’ or shorter

HARNESS GAUGE RECOMMENDATIONS

1500 watt inverter: 

150 amps with a 

maximum voltage drop of 0.5 volts.

2000 watt inverter:

 200 amps with a 

maximum voltage drop of 0.5 volts.

The following tables show the maximum harness cable length 

recommendations for both the 1500 and 2000 watt inverters. 

Summary of Contents for INVERT

Page 1: ...INVERT PURE SINE WAVE USER GUIDE 300 1 Doc 1 00...

Page 2: ......

Page 3: ...eys net CONTENTS General Information 2 General Inverter Safety 3 General Cautions 4 Call outs 6 Installation 6 Harness Gauge Recommendations 8 Operation 9 LED Logic 9 Fault 10 LVD Settings 11 Buzzer 1...

Page 4: ...put voltage and input current even under load to dynamically estimate the battery s state of charge This enables the controller to indicate available battery capacity and turn off when the battery s s...

Page 5: ...verter housing may become uncomfortably warm reaching 140 F 60 C after extended operation Ensure that there are at least 2 inches 5 cm of space around the inverter During operation keep it away from f...

Page 6: ...terminal A reverse polarity connection will result in a blown fuse and may cause permanent damage to the inverter Damage due to reverse polarity is not covered under warranty Do not use the inverter...

Page 7: ...the battery manufacturer s recommendations Never smoke or allow flame near batteries Be careful not to drop metal tools on the battery as this could spark or short circuit the battery or other electr...

Page 8: ...ION CONTAINED IN THIS AWING IS THE SOLE PROPERTY OF KEYS ANY REPRODUCTION IN PART AS A WHOLE WITHOUT THE WRITTEN MISSION OF PURKEYS IS PROHIBITED PRIETARY AND CONFIDENTIAL Eng Appr Date All dimensions...

Page 9: ...It can be installed in either of the following ways Use the provided velcro and stick the clip to the selected location Use the provided flathead screws to mount the clip Step 3 Connect the cable to t...

Page 10: ...e must be 8 position and 8 conductor 8p8c and it cannot be a cross over cable Most RJ45 Ethernet type cables will work as long as the conductors are 24 gauge or larger We recommend the conductors in t...

Page 11: ...OPERATION LED STATUS 1 Solid Green Less than 25 about to shutdown 1 2 Solid Green 25 50 available battery 1 3 Solid Green 50 75 available battery 1 4 Solid Green 75 100 available battery The Invert c...

Page 12: ...d Fault LED solid red LED 2 Undervoltage fault Voltage to inverter is below 9 5 V turn inverter off then back on 1 3 Blinking red Fault LED solid red LED 3 Overvoltage fault Turn off inverter correct...

Page 13: ...dium 2 12 2 Allows the battery to reach about 50 state of charge High 12 4 Allows the battery to reach about 75 state of charge Step 2 Press the power button ten times All lights will turn yellow Step...

Page 14: ...The Invert controller includes a buzzer function that does the following Beep Type Description Short Beep Indicates power button has been pressed Constant Beep LVD shutoff warning will shut off in 30...

Page 15: ...y Purkeys This warranty shall not apply if any Purkeys product is used for a purpose for which it is not designed or is in any way altered without the specific prior written consent of Purkeys ANY Pro...

Page 16: ......

Reviews: