17
If the electrical cord is damaged, it must be replaced
by an electrician or qualified person to avoid
damages.
Installation:
1. Refer to qualified professionals to install the
dehumidifier.
2. The slant of the floor bearing the device must not
exceed 10°.
Note:
This device is not to be used for marine purposes. The
device’s environment must not be polluted by corrosive
gases.
Note :
-
When displace the unit, do not slope over 45° to
avoid any damaging of the compressor.
-
The unit should be operated between 5°C to 32°C
-
When dehumidifying, because of the heat resulted
from the running compressor, the indoor
temperature will rise 1°C to 3°C. It is normal.
-
When indoor temperature is below 10°C, and the
ambient absolute humidity is quite low, it is
unnecessary using the machine.
-
Air inlet and air outlet should be at least 10cm
away from the wall.
-
Try to seal the room to enhance the
dehumidification effect.
-
You should be helped by qualified technician to
install the unit.
18
Introduction :
MODELE
PLC2000
Dehumidification capacity
120 L/DAY
Voltage/Frequency
220-240V/50Hz
Required power
1790 Watts
Noise level
52 Dba/1m
Cooling load
R407C/1.26 Kg
Dimensions
590x440x1115 mm
Net weight
57 Kg