1. GENERAL INFO
• This appliance is a sealed electric radiator designed
for fixed wall-mounted installation.
• This appliance conforms to the standards EN 60 335-1
and EN 60 335-2-30.
• The appliance is insulation class I and has electrical
protection level IP21 if used with the standard connection
box, and electrical protection level IP44 if used with the
standard connection box AND the splash-proof cover (to be
ordered separately) or fitted with a 2-pin Schuko plug.
• This appliance complies with European Directive
2004/108/EC (CE Marking on all appliances).
• The product is supplied with wall brackets and screws.
• The YALI D C is supplied complete with a connection cable
equipped with a 5-pole connector and connection box.
• The YALI D P (where available) is supplied complete with a
connection cable equipped with a 2 -pin Schuko plug.
PLEASE NOTE:
The YALI D P has limited functionality due to only being
equipped with a 2-pin Schuko plug, therefore it will
not be possible to have a wired connection to a central
programmer, external clock, BMS, or to have the radiator
connected in a master/slave setup. However, it is still
possible to connect wirelessly to an LVI RF Central
programmer, or the LVI Touch E3.
2. INSTALLATION
POSITIONING
• The radiator must be positioned horizontally in
order for it to function correctly.
• The radiator must be positioned according to the
applicable standards. The minimum distances as
specified in picture 1 should be carefully observed
(the recommended distance from the floor is 100 mm).
• The radiator may be positioned “outside” zone 2
with the standard connection box and inside zone 2 if
the connection box is equipped with a splash proof cover
(picture 2), insofar as no operating controls (button,
switches, etc …) are in reach of persons in the bath or
under the shower.
• The radiator must be fixed to the wall using the
wall brackets supplied.
• The radiator must not be located underneath an
electrical socket.
FIXING
• Mark out the distance between the brackets and the
positions of the screw holes as shown in the table in picture
3A (single panel YALI D) or 3B (single panel YALI P and YALI R)
or 3C ( double panel). Note that 2000 mm long products are
supplied with extra brackets as a 3rd bracket must be fitted
in the middle of the product.
• Note that the brackets can be used to measure the height
of the bottom fixing hole, see picture 3D (excludes 300
mm high YALI P and YALI R single radiators).
• For the correct installation of radiators it is essential that
the fixing of the radiator is carried out in such a way that
it is suitable for intended use AND predictable misuse. A
number of elements need to be taken into consideration
including the fixing method used to secure the radiator
to the wall, the type and condition of the wall itself,
and any additional potential forces or weights, prior to
finalising installation.
• The fixing materials provided are only intended for
installation on walls made of solid wood, bricks, concrete
or on timber-frame stud walls where the fixing is directly
into the timber. All walls being considered should have
no more than a maximum of 3 mm wall finishing. For
walls made of other materials, for example hollow bricks;
please consult your installer and/or specialist supplier.
In all cases it is strongly recommended that a suitably
qualified professional installer or similar tradesperson
carries out the installation.
CONNECTION
• The electrical installation must comply with local or
national regulations. The radiator should be connected by
a suitable and qualified electrician.
• Please refer to the wiring diagram in picture 4A for the
connection of the radiator (Excludes YALI D P model).
• The radiator must be connected to the electrical supply
using the supply cable fitted to the unit.
• If the radiator is installed in a bathroom or shower room,
it must be protected with a residual current device (RCD)
with a rated residual current not exceeding 30 mA.
65
|