background image

Important safety instructions

PLEASE KEEP THIS MANUAL FOR FUTURE USE

NB! Read all the safety instructions and 
warnings before using your central vacuum 
cleaner.

• This central vacuum cleaner is designed

for vacuuming in dry areas do not use it 
for vacuuming liquid.

• Do not vacuum near smoke, glowing embers,

fire or hot ashes.

• Do not vacuum in areas that may contain

burning or easily flammable liquids and gases. 

• Always pull out the plug before changing the filter or

dust bag, and before servicing.

• When you pull out the plug, pull by the plug,

never pull the cord.

• The outlet and the plug shall be in a clearly visible

place.

• Do not mount the vacuum cleaner into too 

narrow a place. The minimum height of the space 
530mm Width 480mm.

• Do not vacuum sharp objects, such as glass or

needles as they may get stuck in the pipework.

• Do not cover the central unit.

• Always comply with the instructions in this manual.

• The servicing of the vacuum cleaner must only

be carried out by an authorized servicing compa-
ny. Use only spare parts and accessories recom-
mended by the manufacturer. Never try to make 
any alterations into the vacuum cleaner.

• Never use a central vacuum cleaner with a faulty

electrical wire. The central vacuum cleaner has a 
special wire that should always be replaced with 
a wire of the same type. They can be purchased 
at authorised repair shops.

• Remember that the central vacuum cleaner

is not a toy. 

• Never vacuum without a dust bag.

• Always pull out the hose from the suction outlet

after you finish vacuuming.

!

CONTENTS

Safety instructions

The features of the Puzer Easy circuit board

Troubleshooting

Servicing

Using the system

Mounting the central unit

Specifications

Installation of additional suction outlets

2

8

7

6

5

4

3

9

2

Summary of Contents for Easy

Page 1: ...NUAL PUZER EASY www puzer fi Puzer central vacuum cleaner Genuinely Finnish PLEASE READ THIS MANUAL BEFORE USING THE VACUUM CLEANER The small and handy central vacuum cleaner of the Puzer collection Puzer Easy ...

Page 2: ...ass or needles as they may get stuck in the pipework Do not cover the central unit Always comply with the instructions in this manual The servicing of the vacuum cleaner must only be carried out by an authorized servicing compa ny Use only spare parts and accessories recom mended by the manufacturer Never try to make any alterations into the vacuum cleaner Never use a central vacuum cleaner with a...

Page 3: ...0Hz 210 244 is IPX0 8l Puzer Easy is developed especially for apartment and row houses or for renovation sites The exhaust air of the Easy vacuum cleaner is directed through a washable HEPA 12 allergy filter to the installation space A separate exhaust pipe is not needed The mounting of the equipment does not require other operations than fastening it to the wall with four screws The benefit of Ea...

Page 4: ...he central unit toward the filter unit 9 Fasten the weak current wires and the mains cable to the circuit board of the machine 5 Place the central unit directly towards the filter unit Make sure that the rubber pieces behind touch their counterpieces 6 Put the latches to their correct places Support the central unit with your other hand so that it will not fall 7 Push the latch all the way to the ...

Page 5: ...art the vacuum 1 Vacuuming construction or gypsum dust or ashes is strictly forbidden without a pre separator Pre separator 2 Wealt box Puzer Central Vacuum Cleaner is easy to use If your system includes a suction hose with a handle switch push the hose to the suction outlet as in dicated by the image 1 Now you can start and stop the system using the switch in the handle of the suction hose If you...

Page 6: ...water in the direction of the folds so that the water can run along the lamellas see picture 3 Turn the filter and wash from the opposite direction as indicated by the image Continue rinsing until the filter is clean 4 Shake the water carefully off the filter and let it dry for at least an hour before placing the filter back to the vacuum cleaner Do not place a wet filter to the vacuum cleaner Rem...

Page 7: ...art The main fuse shall be of 10A NOTE 230 V ELECTRICAL WORK CAN ONLY BE CARRIED OUT BY A PROFESSIO NAL WHO IS AWARE OF ALL THE SAFETY REGULATIONS LOW SUCTION Are all the suction outlets properly fitted Has something got stuck in the suction outlet Is the dust bag full Is the cover properly placed Are the suction pipes blocked Is the hose blocked Is there a leak in the pipework Are the O rings of ...

Page 8: ... than 400 operation hours 400 499 Orange Over 400 operation hours Over 500 hours Red Over 500 operation hours 4 SELF CHECK When the mains cable is connected the circuit board performs a self check When everything is ok the LED blinks quickly for a few seconds 5 SHUT OFF DELAY The shut off has a two 2 second delay so that the pipe work and hose are surely emptied after the switch off 6 RESET DEMO S...

Page 9: ...ce a washer to the hole The installation can also be start ed with the corner pieces THEINSTALLATIONOFADDITIONALSUCTIONOUTLETS 3 Connect the weak current connection of the additional outlet to the terminal block behind the wall rack INFORMATION In case you need any help with planning and installing your central vacuum system please contact the retailer or manufacturer in the address below Manufact...

Reviews: