background image

FEATURES OF THE PUZER EASY CIRCUIT BOARD

1 - SOFT START

The start peak is limited with a TRIC relay, this way the start power is delivered to the motor with a delay of 1 

second. The start voltage is significantly smaller and the stress of the fuses, network and motor decreases.

 

2 - LOW VOLTAGE LED AUTOPOLARITY *2

The green light in the machine of the pendant is always on when the voltage is connected. 
(i.e. the plug is in the outlet)

3 - OPERATION HOUR COUNTER *3

By using EEPROM technology (erasable programmable ROM), the card registers two two types 
of time, which can be checked by the user only by looking at two separate LEDs located in the 
protective board of the circuit board. 

a. 

Short time 

b. 

Total time

TIME USED

LED COLOUR

MEANS

OPERATION

15 hours

Slow green blinking

The vacuum cleaner has been 
used 15 hours since the last 
receipt

Change/check the dustbag and 

press the receipt button for 5 

seconds

0-399 hours

Green

Less than 400 operation hours

-

400 - 499

Orange

Over 400 operation hours

-

Over 500 hours

Red

Over 500 operation hours

-

4 - SELF CHECK

When the mains cable is connected, the circuit board 
performs a self check. When everything is ok, 
the LED blinks quickly for a few seconds.

5 - SHUT OFF DELAY

The shut off has a two (2) second delay so that the 
pipe work and hose are surely emptied after the 
switch off. 

6 - RESET/DEMO SWITCH *6

Makes the following operations: 

Function 

Operation

Result

Test/demo

Press and release the switch in less 
than 5 seconds. 

The card performs a self check and 
goes through all the phases of the 
previous table (see table 1)

Partial reset

Press the switch for over 5 seconds 
when the motor is not running.

The system will reset the 15 hours’ 
countdown and the blinking LED 
(3) returns to the continuously on 
mode.

Total reset

Press the switch over 30 seconds 
when the engine is running.

The system reset the total time 
calculation.

7 - AUTOMATIC FUSE*7

The circuit board is equipped with an automatic fuse, (the button with the text “circuit breaker”). 
The reset takes place by pushing the button. 

*2

*3

*6

*7

8

Summary of Contents for Easy

Page 1: ...NUAL PUZER EASY www puzer fi Puzer central vacuum cleaner Genuinely Finnish PLEASE READ THIS MANUAL BEFORE USING THE VACUUM CLEANER The small and handy central vacuum cleaner of the Puzer collection Puzer Easy ...

Page 2: ...ass or needles as they may get stuck in the pipework Do not cover the central unit Always comply with the instructions in this manual The servicing of the vacuum cleaner must only be carried out by an authorized servicing compa ny Use only spare parts and accessories recom mended by the manufacturer Never try to make any alterations into the vacuum cleaner Never use a central vacuum cleaner with a...

Page 3: ...0Hz 210 244 is IPX0 8l Puzer Easy is developed especially for apartment and row houses or for renovation sites The exhaust air of the Easy vacuum cleaner is directed through a washable HEPA 12 allergy filter to the installation space A separate exhaust pipe is not needed The mounting of the equipment does not require other operations than fastening it to the wall with four screws The benefit of Ea...

Page 4: ...he central unit toward the filter unit 9 Fasten the weak current wires and the mains cable to the circuit board of the machine 5 Place the central unit directly towards the filter unit Make sure that the rubber pieces behind touch their counterpieces 6 Put the latches to their correct places Support the central unit with your other hand so that it will not fall 7 Push the latch all the way to the ...

Page 5: ...art the vacuum 1 Vacuuming construction or gypsum dust or ashes is strictly forbidden without a pre separator Pre separator 2 Wealt box Puzer Central Vacuum Cleaner is easy to use If your system includes a suction hose with a handle switch push the hose to the suction outlet as in dicated by the image 1 Now you can start and stop the system using the switch in the handle of the suction hose If you...

Page 6: ...water in the direction of the folds so that the water can run along the lamellas see picture 3 Turn the filter and wash from the opposite direction as indicated by the image Continue rinsing until the filter is clean 4 Shake the water carefully off the filter and let it dry for at least an hour before placing the filter back to the vacuum cleaner Do not place a wet filter to the vacuum cleaner Rem...

Page 7: ...art The main fuse shall be of 10A NOTE 230 V ELECTRICAL WORK CAN ONLY BE CARRIED OUT BY A PROFESSIO NAL WHO IS AWARE OF ALL THE SAFETY REGULATIONS LOW SUCTION Are all the suction outlets properly fitted Has something got stuck in the suction outlet Is the dust bag full Is the cover properly placed Are the suction pipes blocked Is the hose blocked Is there a leak in the pipework Are the O rings of ...

Page 8: ... than 400 operation hours 400 499 Orange Over 400 operation hours Over 500 hours Red Over 500 operation hours 4 SELF CHECK When the mains cable is connected the circuit board performs a self check When everything is ok the LED blinks quickly for a few seconds 5 SHUT OFF DELAY The shut off has a two 2 second delay so that the pipe work and hose are surely emptied after the switch off 6 RESET DEMO S...

Page 9: ...ce a washer to the hole The installation can also be start ed with the corner pieces THEINSTALLATIONOFADDITIONALSUCTIONOUTLETS 3 Connect the weak current connection of the additional outlet to the terminal block behind the wall rack INFORMATION In case you need any help with planning and installing your central vacuum system please contact the retailer or manufacturer in the address below Manufact...

Reviews: