Nixie Tube Clock ‘Frank 3’
Issue 5 (1 Jan 2012)
www.pvelectronics.co.uk
- 34 -
7.7 Function of the GPS / RFT indicator LED (D9):
•
No Radio Synchronisation source installed (parameter (12) = 0)
LED is permanently off
•
RFT or GPS Synchronisation enabled (parameter (12) = 1-4)
The LED will be ON if the clock has synchronised in the last two
hours; slowly flashing if the last synchronisation was between 2
hours and 24 hours ago; and off if the last synchronisation is older
than 24 hours.
•
Additionally, if DCF, WWVB or MSF mode is selected, the indicator
will flash rapidly whilst the clock is actually receiving and
processing a valid time frame.
The function of the RFT indicator LED may be summarised in the
table below:
Radio Time
Source
Sync <
2 Hrs
Sync >2 Hrs
Sync < 24 Hrs
Sync > 24
Hrs
Aquiring
RFT Frame
None
Off
Off
Off
-
DCF / WWVB / MSF
On
Slow Flash
Off
Fast Flash
GPS
On
Slow Flash
Off
-