Operation and Maintenance Manual Rev M(ii) 4/03
- 19 -
Machine Safety Check
Once initialize and exhaust verification is complete, the operator interface displays the following message:
Machine Safety Check
Press F1 to initiate.
F1
F2
F3
F4
F5
F6
F7
F8
The machine safety check ensures the workcell safety devices (emergency stop, door interlocks, light
curtain, etc.) are operating properly. During startup, the operator must enter the safety check and complete
it successfully. Otherwise, the machine halts all operations. After pressing F1 the operator is prompted by
the operator interface to activate and deactivate the safety devices and the
POWER ON
button, if present.
Certain events in this procedure are timed and if an action is not performed within a specified time the
machine interprets this as a failure and displays an error screen such as this:
EStop button failed.
Press F1 to repeat test.
F1
F2
F3
F4
F5
F6
F7
F8
By pressing F1 the operator can repeat the test
one
time. If a second failure occurs, a screen such as this
appears:
EStop button failed.
Repair and restart the machine.
F1
F2
F3
F4
F5
F6
F7
F8
After the second failure the program ceases functioning and the machine must be restarted. The second
failure need not be for the same device. An emergency stop failure followed by a door interlock failure
halts the program.
If the safety check fails, the entire system should be thoroughly examined by qualified maintenance
personnel before the machine is returned to operation.
Homing the Axes
Press F1 to home the system.
F1
F2
F3
F4
F5
F6
F7
F8
After successfully completing the safety check, the operator is shown the above screen. Pressing F1 homes
the system and displays the following screen:
Summary of Contents for PVA2000