Operation and Maintenance Manual Rev M(ii) 4/03
- 36 -
Limit Error Recovery Procedure
The machine encounters a limit error in the following cases. First, if the path program attempts to move the
dispense / spray head past one of the software limits. If a software limit caused the error, then either the
path or the software limits must be changed. The operator can check the machine’s status screens by
selecting F5.
Limit Error. F1-restart, F5-status.
Stop codes (x,y,z,w) 000, 000, 000, 000
F1
F2
F3
F4
F5
F6
F7
F8
1) Open the access door.
2) Move the dispense / spray head to the center of the work area. The Z axis is equipped with a brake (all
model except PVA250™). The motor coupling can be turned by hand to move the head towards the
center of the work area.
3) Close the access door.
4) Press F1 to clear the error.
5) Follow the startup procedure.
Stop Codes
(All models except PVA250™, PVA750™, PVA2000C™)
For Position and Limit Errors, the error screen displays the stop codes for all the motors. This information
tells the operator which axis (or axes) caused the machine to go to fault.
Table 5 – Stop Code Definitions
Code
Meaning
0
Motors are running, independent mode.
1
Motors stopped at commanded independent position.
2
Decelerating or stopped by FWD limit switch or software limit, FL.
3
Decelerating or stopped by REV limit switch or software limit, BL.
4
Decelerating or stopped by Stop Command (ST).
6
Stopped by Abort input.
7
Stopped by Abort command (AB).
8
Decelerating or stopped by Off-on-Error (OE1).
9
Stopped after Finding Edge (FE).
10
Stopped after Homing (HM).
50 Contour
running.
51 Contour
Stop.
99 MC
timeout.
100
Motors are running, vector sequence.
101
Motors stopped at commanded vector.
Startup Errors
The program saves several variables in the EEPROM through power-down. If the variables are not present
or they are out of bounds the following message is displayed. The program automatically initializes the
variables and recover from the error.
Summary of Contents for PVA2000