Operation and Maintenance Manual Rev M(ii) 4/03
- 56 -
Appendix C – Error Codes
DMC Error Codes
Table 13 – DMC Error Codes
ID Description
1 Unrecognized
command
2 Command only valid from program
3 Command not valid in program
4 Operand
error
5 Input buffer full
6 Number out of range
7 Command not valid while running
8 Command not valid while not running
9 Variable
error
10 Empty program line or undefined label
11 Invalid label or line number
12 Subroutine more than 8 deep
13 JG only valid when running in jog mode
14 EEPROM check sum error
15 EEPROM checkwrite error
16 IP incorrect sign during position move or IP given during forced deceleration
17 ED, BN and DL not valid while program running
18 Command not valid when contouring
19 Application strand already executing
20 Begin not valid with motor off
21 Begin not valid while running
22 Begin not possible due to Limit Switch
24 Begin not valid because no sequence defined
25 Variable not given in IN command
28 S operand not valid
29 Not valid during coordinated move
30 Sequence segment too short
31 Total move distance in a sequence > 2 billion
32 More than 511 segments in a sequence
41 Contouring record range error
42 Contour data being sent too slowly
46 Gear axis both master and follower
47 Gearing and coordinated moves cannot run simultaneously
50 Not enough fields
51 Question mark not valid
52 Missing " or string too long
53 Error in {}
54 Question mark part of string
55 Missing [ or []
56 Array index invalid or out of range
57 Bad function or array