10.11 Using Tool Box Menu
The TOOL BOX MENU contains several adjustable parameters as well as up to the 15 past alarm messages
logged.
1. The first screen in the Tool Box is for the ACCESS level. The three choices available here are USER, INSTaller
and ADVanced. Depending on the controls software revision, the ADVanced level can be selected using the UP
and DOWN arrow buttons for the first revision. Subsequent software revisions require that button #4 in the
bottom right corner be pressed and held in order to place the control in the ADVanced access level. Consult
factory before changing any settings requiring an ADVanced access level. Depending on the access level
selected, different parameters will become visible and adjustable. Selecting the appropriate access level will
make menu navigation easier and minimize the possibility that parameters will be unintentionally changed,
resulting in improper operation.
2. The second screen will display the software revision for the touch panel display. Press the enter button to view.
3. The third screen allows the user to turn the display backlight ON continuously, OFF or TMPY will keep the
backlight on only during use.
4. The fourth screen allows the user to choose between Fahrenheit and Celsius.
5. All of the following screens will display the most recent alarm messages up to 15. The Status field will show
messages beginning with the most recent. This screen will display the time and date of the failure.