General Installation Manual
© PV Products GmbH, Wernersdorf 111, 8551 Wies, Austria
Updated: September 2011
The module may not be mounted on the short sides as the load capacity of the module of
5,400 N/m² can otherwise no longer be guaranteed.
The installation location of the modules must be selected in such a manner that they are not
positioned in the shade of other objects such as trees or buildings. It is also necessary to
consider potential partial shade created by objects throughout the day.
Figure 1: Attachment points for the PV module
modul type
PVP-AxxxMWFHK2
PVP-AxxxMWFLK1
max. load
length
PVP-AxxxPWFHM2
PVP-AxxxPWFLM1
PVP-AxxxPWFLM3
L1 [mm]
1309
1629
1949
L2 [mm]
989
989
989
5400 N/m²
L3 [mm]
262
325
390
2400 N/m²
L4 [mm]
170
220
270
L5 [mm]
355
430
510
5400 N/m²
L4 [mm]
200
260
310
L5 [mm]
320
390
465
Table 1: Length
grounding hole