7.6. COUNTER INPUT SETTINGS
7.7. ALERT OUTPUT
Counting Input Settings
menu allows to change some values and the characteristic
parameter of the anemometer (Transducer output) of formula 1 [Hz] = x [m / s].
The default is set to 0.1 [m / s], but be sure to check this parameter and (if needed) to
change after connection of the new anemometer.
Another option you can set is the counting input configuration. Sometimes there is need
to change the type of electric signal amplifying transistor (PNP or NPN) dependent on
the anemometers (or if both types of method connecting to the device are used).
To change the type select the field
and confirm with
.
polarization
enter
Alarm output
allows the individual set the parameters on and off the alarm output.
Time
On Set
determines how many seconds takes to turn on the alarm, during which the wind
speed exceeds a threshold alarm. Time Off Set is the time after which the alarm turns
off, the alarm status changes if wind speed decreases below the predetermined
threshold.
Remember to save values in
menu
by selecting the
button
and pressing
set
enter
Remember to save values in
menu
by selecting the
button
and pressing
set
enter