background image

5

Connection scheme

Presented below are the possible colors of the wire used in the lamp.

 

The 

cable should be connected as described.

 

Lamps should only be connected 

parallel.

1. + (red)

2. - (black)

1. + (brown)

2. - (white)

a) sample connection of the PX291 to a PX254 driver

8

LED driver

power supply 12V DC

V- V+

L N

The cables should be connected in the correct  
color order. For example, the red wire with  
the + terminal and the black wire with 
the R- / B- / G- terminal. 
The number of LED lamps depends on t 
he driver and power supply.

Summary of Contents for PX291

Page 1: ...PX291 PxAqua 3 SF 12V User manual...

Page 2: ...tion 7 5 Connection scheme 8 6 Dimensions 9 7 Technical data 10 Manufacturer reserves the right to make modifications in order to improve device operation PXM Marek upnik sp k Pod e 654 32 003 Pod e B...

Page 3: ...available in white color in 3 different color temperatures cold white neutral white and warm white The PX291 may be provided with optic beam angles of 10 22 standard or 40 The casing is made of stainl...

Page 4: ...rns Warning Read the instruction manual Caution Do not look at the LEDs LEDs can cause damage or eye irritation Do not look at the light source with any optical devices that focus the light rays Light...

Page 5: ...ble with technical data 3 All the conductors should be protected against mechanical and thermal damage 4 In the event of damaging any conductor it should be replaced with a conductor of the same techn...

Page 6: ...ere is a description of designation of the PX291 models and their explanation PX291 XX YYY ZZ XX lens angle 10 10 22 22 40 40 YYY color LEDs W warm white N neutral white C cold white ZZ lamp housing v...

Page 7: ...in underwater installations such as fountains swimming pools and places exposed to adverse weather conditions 4 Model description 1 Mounting holes 2 Directional diffuser in the shape of a honeycomb re...

Page 8: ...e connected parallel 1 red 2 black 1 brown 2 white a sample connection of the PX291 to a PX254 driver 8 LED driver power supply 12V DC V V L N The cables should be connected in the correct color order...

Page 9: ...lamp with the voltage power supply 6 Dimensions 9 voltage power supply 12V DC V V L N When mounting the lamp you need to leave enought space for cable gland from which goes out the power cord 89 mm 55...

Page 10: ...s 3 current consumption 350mA IP rate IP68 housing stainless steel 316L CRI 80 lighting angles 10 22 40 available LED colors cold white neutral white warm white brightness 22 1m 1120lx weight 0 6kg di...

Page 11: ...ell as harmonised standards PN EN IEC 63000 2019 01 PN EN 60598 1 2015 PN EN 62471 2010 EN IEC 63000 2018 EN 60598 1 2015 EN 62471 2008 and meets the essential requirements of the following directives...

Reviews: