Safety conditions

Caution! Before installing, connecting and using the lamp you have to

absolutely read this document.

The following symbols are used to underline important information on 
security on the product and in this manual.

Danger!

Risk of loss of life

and health

Warning!

Fire hazard

Warning!

LED light emission,

the risk of eye

damage

Warning!

 The risk of burns

Warning!

Read the instruction

manual

Caution!

Do not look at the LEDs, LEDs can cause damage or eye irritation. Do not look 
at the light source with any optical devices that focus the light rays.

Light is harmful to unprotected eyes, can cause irritation, eye 

damage or even loss of eyesight.

While working outdoors in normal conditions, the housing unit 

can heat up to +65°C. Make sure that accidental contact with 

the device during use is impossible.

In case of improper usage of the product it may cause a risk of

serious injury or death because of the threat of fire.

4

Summary of Contents for PX800-W

Page 1: ...PX800 W PxArt 06 Wall PxArt 12 Wall PxArt 18 Wall User manual...

Page 2: ...arameters 10 6 2 Scheme of the PX800 W menu in PX277 12 7 RDM available parameters 13 8 DMX signal connecting 15 9 Mounting 15 10 Connection scheme 16 11 Dimensions 17 12 Technical data 18 Manufacture...

Page 3: ...and small energy consumption Modern electronics allowed to create a lamp that is devoid of the effect of light vibration flicker free technology in the full control range which makes it useful in the...

Page 4: ...s Warning Read the instruction manual Caution Do not look at the LEDs LEDs can cause damage or eye irritation Do not look at the light source with any optical devices that focus the light rays Light i...

Page 5: ...d must meet the safety requirements the installation must be 3 wire and equipped with a residual current device 3 All the conductors should be protected against mechanical and thermal damage 4 In the...

Page 6: ...AA XX Z AA version 06 6 LEDs 12 12 LEDs 18 18 LEDs XX beam angle 10 10 20 20 30 30 40 40 EL elliptical lenses WW Wall Washer Z housing colors 1 gray 2 black 3 white not available for the PX800 W 06 la...

Page 7: ...ess adjustment button 1Hz frequency in the first minute after receiving the DMX signal after the start of the lamp in case of the loss of DMX signal diode lights continuously for 1 minute if the state...

Page 8: ...rightness is increased release the control button for a moment The diode will signal the change of adjustment direction The pressing of the adjustment button again will cause the dimming of the lamp b...

Page 9: ...lled via two DMX channels Channel 1 color Channel 2 brightness Setting the lamp parameters Value of the lamp parameter Value of the DMX signal Adjusting the color temperature 4500K 255 3600K 128 2700K...

Page 10: ...DMX address of the color temperature and brightness channel in the range 1 512 No Signal behavior of the device when the DMX signal disappears Scene setting the scene displayed when the DMX signal di...

Page 11: ...t and current operating temperature of the module with LEDs PWR time ACT time total lamp operation time total lamp lighting time Factory Default factory reset in PX800 W DMX Addr 001 No Signal Off Sce...

Page 12: ...nal Hold Channel 1 Value 128 NEXT Channel 1 Value 255 Channel 1 Value 128 NEXT Channel 2 Value 128 ENTER PREV No Signal Time 0 0 s No Signal Time 1 0 s NEXT No Signal Time 10 0 s ENTER No Signal Time...

Page 13: ..._PARAMETERS 0x0050 all supported parameters PARAMETER_DESCRIPTION 0x0051 description of additional parameters DEVICE_INFO 0x0060 information concerning the device SOFTWARE_VERSION_LABEL 0x00C0 firmwar...

Page 14: ...ted temperature sensor SENSOR_VALUE 0x0201 information about sensors SMOOTH_OFF 1 2 3 4 0x801A selection of smoothing options NO_SIGNAL_OFF ON HLD S 0x801C behavior of the device when the DMX signal d...

Page 15: ...below If the PX800 W is the last device in the DMX line then a terminator 120 Ohm resistor should be connected to the DMX and DMX terminals DMX IN GND CORRECT DMX 512 input DMX 512 output DMX IN GND...

Page 16: ...10 Connection scheme 16 L N PE GND DMX DMX L N PE GND DMX DMX L N PE GND DMX DMX 230V AC DMX controller DMX PX800 W PX800 W PX800 W Max 32 devices on the line Terminator 120 Ohm resistor...

Page 17: ...11 Dimensions PxArt 06 Wall PxArt 12 Wall 121 252 185 92 121 90 107 67 279 262 200 213 149 122 256239 wersja WW Wallwasher 239 WW Wallwasher version 17...

Page 18: ...2 Technical data type PX800 W power supply 230V AC number of diodes 6 12 18 power consumption PX800 W 06 10W PX800 W 12 17 5W PX800 W 18 25W max temperature rise housing 30 C luminous flux PX800 W 06...

Page 19: ...800 W 06 1 5kg PX800 W 12 1 9kg PX800 W 18 2 6kg dimensions height PX800 W 06 252mm diameter PX800 W 06 92mm height PX800 W 12 262mm diameter PX800 W 12 122mm height PX800 W 18 279mm diameter PX800 W...

Page 20: ...directives 2011 65 UE DIRECTIVE OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment Text...