22
Range Resolution
Accuracy
400.0uA 0.1uA
4000uA 1uA
40.00mA 10uA
400.0mA 100uA
+1.2% of rdg + 3 digits
10A 10mA +2.5% of rdg + 3 digits
Overload Protection: 0.5A / 1000V and 10A / 1000V Fuse.
Maximum Input:
400uA dc on uA range
400mA dc on mA range
10A dc on 10A range.
AC Current
(Auto-ranging)
Range Resolution
Accuracy
400.0uA 0.1uA
4000uA 1uA
40.00mA 10uA
400.0mA 100uA
+1.5% of rdg + 5 digits
10A 10mA +3.0% of rdg + 5 digits
Overload Protection: 0.5A / 1000V and 10A / 1000V Fuse.
AC Response: 50 Hz to 60 Hz
Maximum Input:
400uA ac rms on uA
400mA ac rms on mA
10A ac rms on 10A range.