background image

CAUTION:

WARNING:

To reduce the risk of fire or electrical shock, do not expose this appliance to
rain or moisture.

DETAILED SAFETY INSTRUCTIONS:

All the safety and operation instructions shouldbe read before the appliance is operated.

SAFETY INSTRUCTIONS

Retain Instructions:

The safety and operating instructions should be retained for futurereference.

Heed Warnings:

All warnings on the appliance and in the operating instructions should be adhered to.

Follow instructions:

All operation and user instructions should be followed.

Water and Moisture:

The appliance should not be used near water ( e.g. near a bathtub,washbowl,kitchen sink,
laundry tub,in a wet basement,or near a swimming pool etc. )

Heat:

The appliance should be situated away from heat sources such as radiators, heat registers,
stoves, or other appliance ( including amplifiers ) that produce heat.

Power source:

The appliance should be connected to a power supply only of the type described in the
operating instructions or as maked on the appliance.

Grounding or Polarization:

Precautions should be taken so that the grounding or polarization means of an appliance is
not defeated.

Power-Cord Protection:

Power supply cords should be routed so that they are not likely to be walked on or pinched
by items placed upon or against them, paying particular attention to cords and plugs,
convenience receptacles and the point where they exit from the appliance.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

This symbol, wherever it appears, alerts you to important operating and
maintenance instructions in the accompanying literature. Read the manual.

This symbol, wherever it appear, alerts you to the presence of uninsulated
dangerous voltage inside the enclosure - voltage that

be sufficient to

may

constitute a risk of shock.

The appliance should be situated so that its location or position does not interfere with its
proper ventilaton. For example,the appliance should not be situated on a bed,sofe rug,or
similar surface that may block the ventilation openings:or placed in a built - in installation,
such as bookcase or cabinet that may impede the flow of air through the ventilation
openings.

Cleaning:

The appliance should be cleaned only as recommended by the manufacturer.

To reduce the risk of electrical shock, do not remove the cover ( or back ) .No
user serviceableparts inside; refer servicing to qualified personnel.

Ventilation:

Summary of Contents for PPCX2

Page 1: ...UT HIGH GAIN HIGH GAIN XOVER FREQ XOVER FREQ SUB GAIN SUB GAIN 30HZ LOW CUT 30HZ LOW CUT 30HZ LOW CUT 30HZ LOW CUT LOW GAIN LOW GAIN XOVER FREQ XOVER FREQ XOVER FREQ XOVER FREQ HIGH GAIN HIGH GAIN SUB WOOFER ON OFF CHANNEL 2 CHANNEL 1 ON OFF ON OFF ON OFF 2 WAY STEREO CROSSOVER PLUS SUBWOOFER 2 way stereo plus subwoofer INSTRUCTION MANUAL ACTIVE CROSSOVERS English ...

Page 2: ...rization means of an appliance is not defeated Power Cord Protection Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them paying particular attention to cords and plugs convenience receptacles and the point where they exit from the appliance CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN This symbol wherever it appears alerts y...

Page 3: ...e has been exposed to rain or The appliance dose not appear to operate normally or exhibits a marked change in performance or The appliance has been dropped or the enclosure damaged Servicing The user should not attempt to service the appliance beyond that is describedin the Instructions All other servicing should be referred to qualifield service personnel Operating HIGH AMP LOW AMP SUB AMP TYPIC...

Page 4: ...alanced 1 4 100 Kohms Outputs Unbalanced 1 4 220 Ohms 30Hz 3dB 12dB Octave 20Hz 25KHz 1dB 0 05 95 dB 95 120V AC 200mA 250VAC slow blow 5 51lb 2 5 Kg Crossover Type Crossover Range Filter Type Slope Type Impedance Type Impedance Low Cut Filters Frequency Response Total Harmonic Distortion THD Noise S N Ratio Fuse Dimensions Weight 483 194 5 44mm 19 W 7 7 D 1 7 H SPECIFICATIONS 210 240V AC T100mAL 2...

Page 5: ... way of each stereo channel with a 12dB Octave 30Hz HPF to minimize problems from subsonic frequencies in the signal to suppress hum and to prevent low frequency speaker resonance 11 12 10 10 11 11 1 10 OFF 1 7K 4 1K 6K 250 390 880 OFF 10 OFF 10 170 230 250 50 70 120 OFF 10 1 7K 4 1K 6K 250 390 880 OFF 10 PHASE PHASE LOW GAIN LOW GAIN 30HZ LOW CUT 30HZ LOW CUT HIGH GAIN HIGH GAIN XOVER FREQ XOVER ...

Page 6: ...e outputs of your power amplifiers to avoid possible speaker damage This selects the crossover frequency of the SUB WOOFER way You can select the frequency between 50 Hz to 250 Hz This is used to adjust the SUB WOOFER output level This inserts a low cut filter in the SUBWOOFER way with a 12dB Octave 30 Hz HPF to minimize problems from subsonic frequencies in the signal to suppress hum and to preve...

Reviews: