[M]
[M]
2 seconds
Factory Default
Display
Factory Default Display
Factory Default Display
"DONE" Display
Factory Default Adjustment
"YES" Display
"NO" Display
Absolute Pressure
Display
Absolute Pressure Display
Absolute Pressure Display
Absolute Pressure Display
Barometer Mode
Barometer Mode
hold
[M]
hold
[M]
hold
[M]
hold
[M]
hold
[M]
Adjustment Displays
[S/S] / [L/R]
Barometer Mode
current
temperature
Current
Sea level
pressure
current
ambient
pressure
current
ambient
pressure
current
time
[L/R]
[L/R]
History Graph Display
(Current Time)
Temperature Display
Sea Level Pressure Display
[S/S]
[S/S]
[S/S]
History Graph Display
(1st Record at the hour)
cursor moving
direction
flashing cursor
(1 st record at the hour)
record time
(flashing)
[L/R]
[L/R]
History Display
(-2 to -23 hour)
Sea Level Pressure
History Review
- 23
hour
current
time
SET
Measuring Unit Selection Sequence
8
C (Celsius)
inHg
8
C (Celsius)
mb/hPa
8
F(Fahrenheit)
mb/hPa
8
F (Fahrenheit)
inHg
hold
[S/S]
hold
[S/S]
hold
[S/S]
hold
[S/S]
hold
[S/S]
SET
[S/S]
[S/S]/[L/R]
hold
[S/S]/[L/R]
[S/S]
Increase (decrease)
the number
Increase (decrease)
the number
at a higher speed
Sea level
pressure
history
Sea level
pressure
history
12.1 Barometer Mode -
Measurement Unit Selection and Barometer Adjustment
12.2 Barometer Mode -
Absolute Pressure Adjustment
12.3 Barometer Mode -
Factory Default Adjustment
How to Switch between Measurement Units
!
The Watch can display pressure in mb/hPa or
inHg; the Watch can display temperature in
degree Celsius ( C) or degree Fahrenheit ( F).
!
To switch among different unit, hold down the
[S/S] button to change the units following the
adjacent units selection sequence.
Why the Barometer Need to be Adjusted
!
The Watch was calibrated for you in the factory.
For normal use, you need not to calibrate the
Barometer.
!
But for vigorous users, the Watch includes a
adjustment procedure.
8
8
Barometer Adjustment
!
There are 2 kinds of Barometer adjustment
method: Absolute Pressure and Factory Default
Adjustment.
!
Absolute Pressure: Input the known atmospheric
pressure into the Watch directly.
!
Factory Default: Restore the Watch to factory
default setting.
!
For in-depth information for each of the adjustment
methods, it will be given in the coming sections.
NOTE
: When the Ski Function is turned ON,
Barometer Adjustment function is prohibited.
Before Calibrating the Barometer
!
Before calibrate the Barometer, you must have
the absolute pressure of your current position,
because that pressure value will be inputted into
the Watch during the adjustment.
!
Consult the nearest observatory station to get
the ambient barometric pressure of your current
position.
IMPORTANT:
Input a incorrect pressure during the
calibration procedure, it results a mistaken pressure
reading in future.
How to Adjust the Barometer by Using Absolute
Pressure Adjustment
!
The Watch can adjust the current pressure
reading to a absolute pressure value.
To adjust the Watch by using
, press the [S/S] button in
Display, and the pressure reading will
appear.
!
When pressure reading is appear, press the [S/S]
or [L/R] button to increase / decrease the
number. ( Hold down the button changes the
number at a higher speed).
!
If the setting is completed, hold the [M] button to
confirm setting and exit the adjustment display.
!
To select the Adjustment Display, hold the [M]
button in Barometer Mode. Then press the [M]
button to select between the Absolute Pressure
Adjustment and Factory Default Adjustment.
!
Absolute Pressure
Adjustment
Absolute
Pressure
How to Adjust the Barometer by Using Factory
Default Adjustment
The Watch can also adjust the pressure reading
calculation back to using factory default value.
To adjust the Watch by using factory default
adjustment, press the [S/S] button in Factory
Default Display, and the indicator "NO" will
appear.
!
When the indicator "NO" is appeared, press the
[S/S] or [L/R] button to select between "YES"
(reset the Watch to factory default) or "NO"
(abort the resetting).
!
To exit Adjustment Display, hold the [M] button
for 2 seconds, and then the Watch will go back
to Barometer Mode. If the "YES" Display is
selected when exit the Adjustment Display, the
"DONE" Display will appear for 2 seconds prior
to the normal operation.
!
!
To select the Adjustment Display, hold the [M]
button in Barometer Mode. Then press the [M] to
select between Absolute Pressure Adjustment
and Factory Default Adjustment.
!
Functional Display
!
The Watch includes three Barometer functional
displays: Temperature, Sea Level Pressure and
History Graph Display. One of the three functional
displays will be appeared on the top row of the
display.
Fast sampling
!
During the Altitude Mode, hold down the [L/R] button
will activate fast sampling (sample per second) for
five minutes.
Temperature Display
!
In Temperature Display, the current temperature in
degree Celsius ( C) or degree Fahrenheit ( F) shows
on the top row of the display.
IMPORTANT:
If you want to have an accurate reading
of air temperature, you must remove the Watch from
the wrist (for 20 to 30 minutes) that allows no body
temperature effect on your watch.
Sea Level Pressure Display
!
In Sea Level Pressure Display, the sea level
pressure shows on the top row of the display.
History Graph Display
!
T h e W a t c h r e c o r d s t h e p r e s s u r e r e a d i n g
automatically every hour at the hour, i.e 1:00, 2:00,
3:00 and etc. These records will be plotted into a
pressure record graph.
!
In History Display, the pressure record graph shows
on the top row of the display.
!
To review the pressure records of the last 23 hours,
press the [L/R] button to move cursor left cyclically,
t h e n t h e r e s p e c t i v e p r e s s u r e r e c o r d a n d i t s
recording time (flashing) will appear on the display.
8
8
12.0 Barometer Mode -
Temperature and History Display