background image

[M]

[M]

2 seconds

Factory Default  

Display

Factory Default  Display

Factory Default  Display

"DONE" Display

Factory Default Adjustment

"YES" Display

"NO" Display

Absolute Pressure

Display

Absolute  Pressure  Display

Absolute  Pressure  Display

Absolute  Pressure  Display

Barometer Mode

Barometer Mode

hold

[M]

hold

[M]

hold

[M]

hold

[M] 

hold

[M]

Adjustment Displays

[S/S] / [L/R]

Barometer Mode

current
temperature

Current 
Sea level 
pressure

current 
ambient 
pressure

current 
ambient 
pressure

current
time

[L/R]

[L/R]

History Graph Display

(Current Time)

Temperature Display

Sea Level Pressure Display

[S/S] 

[S/S] 

[S/S] 

History  Graph  Display

(1st  Record  at  the  hour)

cursor  moving 
direction

flashing  cursor
(1  st  record  at  the  hour)

record  time
(flashing)

[L/R]

[L/R]

History  Display
(-2  to  -23  hour)

Sea Level Pressure
History Review

- 23

hour

current
time

SET

Measuring Unit  Selection Sequence

8

C (Celsius) 

inHg 

8

C (Celsius) 

mb/hPa

8

F(Fahrenheit)

mb/hPa

8

F (Fahrenheit)

inHg

hold

[S/S]

hold

[S/S]

hold

[S/S]

hold

[S/S]

hold

[S/S]

SET

[S/S]

[S/S]/[L/R]

hold

[S/S]/[L/R]

[S/S]

Increase (decrease) 
the number

Increase (decrease) 
the number
at a higher speed

Sea level 
pressure
history

Sea level 
pressure
history

12.1 Barometer Mode - 

Measurement Unit Selection and Barometer Adjustment 

12.2 Barometer Mode - 

Absolute Pressure Adjustment

12.3 Barometer Mode - 

Factory Default Adjustment

How  to  Switch  between  Measurement  Units

!

The  Watch  can  display  pressure  in  mb/hPa  or 
inHg;  the  Watch    can  display  temperature  in 
degree  Celsius  ( C)  or  degree Fahrenheit  ( F).

!

To  switch  among  different  unit,  hold  down  the 
[S/S]  button  to  change  the  units  following  the 
adjacent   units  selection  sequence.

Why  the  Barometer  Need  to  be  Adjusted

!

The  Watch  was  calibrated  for  you  in  the  factory. 
For  normal  use,  you  need  not  to  calibrate  the   
Barometer. 

!

But  for  vigorous  users,  the  Watch  includes  a 
adjustment  procedure.

8

8

Barometer  Adjustment 

!

There  are  2  kinds  of  Barometer  adjustment 
method:  Absolute  Pressure  and  Factory  Default 
Adjustment.

!

Absolute  Pressure:  Input  the  known  atmospheric 
pressure into the Watch directly.

!

Factory Default: Restore  the  Watch  to  factory 
default setting.

!

For in-depth information for each of the adjustment 
methods, it will be given in the coming sections.

NOTE

:  When  the  Ski  Function  is  turned  ON, 

Barometer Adjustment function is prohibited.

Before  Calibrating  the  Barometer 

!

Before  calibrate  the  Barometer,  you  must  have 
the absolute  pressure  of  your  current  position,   
because that pressure  value  will  be  inputted  into 
the Watch  during  the  adjustment.

!

Consult  the  nearest  observatory  station  to  get 
the  ambient barometric  pressure  of  your  current 
position.

IMPORTANT:

  Input  a  incorrect  pressure  during  the 

calibration  procedure,  it  results  a  mistaken  pressure 
reading  in  future.  

How  to  Adjust  the  Barometer  by  Using  Absolute 
Pressure  Adjustment

!

The  Watch  can  adjust  the  current  pressure 
reading  to  a  absolute  pressure  value.

To  adjust  the  Watch  by  using 

,  press  the  [S/S]  button  in 

Display,  and  the  pressure  reading  will 

appear.

!

When  pressure  reading  is  appear,  press  the [S/S] 
or  [L/R]  button  to  increase  /  decrease  the 
number.  (  Hold down  the  button  changes  the 
number  at  a  higher speed).  

!

If  the  setting  is  completed,  hold  the  [M]  button  to 
confirm  setting  and  exit  the  adjustment  display.

!

To  select  the  Adjustment  Display,  hold  the  [M] 
button  in  Barometer  Mode.    Then  press  the  [M] 
button  to  select  between  the  Absolute  Pressure 
Adjustment  and  Factory  Default Adjustment.

!

Absolute  Pressure 

Adjustment

Absolute 

Pressure 

 

How  to  Adjust  the  Barometer  by  Using  Factory 
Default  Adjustment

The  Watch  can  also  adjust  the  pressure  reading 
calculation  back  to  using  factory  default  value.

To  adjust  the  Watch  by  using  factory  default 
adjustment,  press  the  [S/S]  button  in  Factory 
Default  Display,  and  the  indicator  "NO"  will 
appear.

!

When  the  indicator  "NO"  is  appeared,  press  the 
[S/S]  or  [L/R]  button  to  select  between  "YES" 
(reset  the  Watch  to  factory  default)  or  "NO" 
(abort  the  resetting).  

!

To  exit  Adjustment  Display,  hold  the  [M]  button 
for  2  seconds,  and  then  the  Watch  will  go  back 
to  Barometer  Mode.    If  the  "YES"  Display  is 
selected  when  exit  the  Adjustment  Display,  the 
"DONE"  Display  will  appear  for  2  seconds  prior 
to  the  normal  operation.

!

!

To  select  the  Adjustment  Display,  hold  the  [M] 
button  in  Barometer  Mode.   Then  press  the  [M]  to 
select  between  Absolute  Pressure  Adjustment 
and  Factory  Default Adjustment.

!

Functional  Display

!

The  Watch  includes  three  Barometer  functional 
displays:  Temperature,  Sea  Level  Pressure  and 
History  Graph  Display.  One  of  the  three  functional 
displays  will  be  appeared  on  the  top  row  of  the 
display. 

Fast  sampling

!

During  the Altitude  Mode,  hold  down  the  [L/R]  button 
will  activate  fast  sampling  (sample  per  second)  for 
five  minutes.

Temperature  Display

!

In  Temperature  Display,    the  current  temperature  in 
degree  Celsius  ( C)  or  degree  Fahrenheit  ( F)  shows 
on  the  top  row  of  the  display.

IMPORTANT:

  If  you  want  to  have  an  accurate  reading 

of  air  temperature,  you  must  remove  the  Watch  from 
the  wrist  (for  20  to  30  minutes)  that  allows  no  body 
temperature  effect  on  your  watch. 

Sea  Level  Pressure  Display

!

In  Sea  Level  Pressure  Display,  the  sea  level 
pressure  shows  on  the  top  row  of  the  display.

History  Graph  Display

!

T h e   W a t c h   r e c o r d s   t h e   p r e s s u r e   r e a d i n g  
automatically  every  hour  at  the  hour,  i.e  1:00,  2:00, 
3:00  and  etc.  These  records  will  be  plotted  into  a 
pressure  record  graph. 

!

In  History  Display,  the  pressure  record  graph  shows 
on  the  top  row  of  the  display.  

!

To  review  the  pressure  records  of  the  last  23  hours, 
press  the  [L/R]  button  to  move  cursor  left  cyclically, 
t h e n  t h e  r e s p e c t i v e  p r e s s u r e  r e c o r d  a n d  i t s 
recording  time  (flashing)  will  appear  on  the  display.

8

8

12.0 Barometer Mode - 

Temperature and History Display

Summary of Contents for WEATHERSKIMASTER

Page 1: ...free paper Blinding Saddle wire Paper Wood free paper Paper weight 100 gms Language English folding line saddle wire 90 mm 130 mm 130 mm WeatherSkiMaster InstructionManual Projectno art05 054Version 1...

Page 2: ...Front Cover Back Cover Instruction Manual WEATHERSKIMASTER...

Page 3: ...Time Daily Alarm Chronograph Timer and Dual Time Mode To select among Ski Ski Recall Altimeter Barometer and Compass Mode To select among the setting items during setting display Sensor Button SR To...

Page 4: ...down the button change the number at a higher speed When month day order setting is selected press the S S or L R button to select between month day and day month format When 12 24 hour format settin...

Page 5: ...to get another lap time How to Recall Lap Times To recall lap times hold down the M button in the Chronograph Display When the Total Time Display is appeared press the S S or L R button to check the n...

Page 6: ...To start a new counting by using a new target time set the timer again by QSV or UPV Dual Time Mode The Watch includes a function to show the current time for a second time zone Dual Time Mode The sec...

Page 7: ...the user must taken off the watch from the wrist for 20 to 30 minutes before the actual measurement It allows no body temperature effect on the Watch Display Display Once the Ski Mode is selected per...

Page 8: ...is stopped and the altitude loss is not significant the decent time timer will stop counting automatically and the current ski lap is saved How to Activate a Ski Lap Manually Press the M button once i...

Page 9: ...The maximum descent speed The highest altitude reached The lowest altitude reached and The slope of the ski course The Ski Lap logs the data of a particular ski lap and it includes The lap started tim...

Page 10: ...l site Factory Default Restore the Watch to default factory setting where assume Sea Level Pressure is 1013 2 mb NOTE When the Ski Function is turned ON Altimeter Adjustment function is prohibited NOT...

Page 11: ...er speed 11 4 Altimeter Mode Zero Altitude Adjustment Adjust the Altimeter by Using Zero Altitude Adjustment To adjust the Watch by using press the S S button in Display and the indicator NO will appe...

Page 12: ...rometer by Using Absolute Pressure Adjustment The Watch can adjust the current pressure reading to a absolute pressure value To adjust the Watch by using press the S S button in Display and the pressu...

Page 13: ...ally IDLE Mode If no any key operation for about 1 minute the Watch will go to the IDLE Mode automatically To activate the compass again press any button Distortion If distortion is detected the indic...

Page 14: ...n 228 E true bearing 3008 true bearing 3008 magnetic bearing 3238 magnetic bearing 2788 true north 08 true north 08 magnetic north magnetic north object B object B point A point A 13 7 Compass Mode Ma...

Page 15: ...ination of the city which is close to your current position That angle will be inputted into the Watch during the calibration To select Magnetic Declination Display press the M button in Rotation Cali...

Page 16: ...ange 99 hours 59 minutes 59 99 seconds Measuring Mode 100 lap memories Recall lap memories and total time Barometer Mode Resolution 0 1 hPa mbar 0 01 inHg Measuring Range 300 hPa mbar to 1100 hPa mbar...

Reviews: