EN
56
Operating Manual: PX-1C - Smoke Alarm Device with Radio Link
Operating Manual: PX-1C - Smoke Alarm Device with Radio Link
EN
57
Note the following for straight mounting
surface less than 1 m long and 1 m wide:
f
Observe chapter „Rooms with
straight ceilings (slope angle < 20°)“
on page 54).
< 1,00
> 0,50
< 1,00
> 20
°
Fig. 18 Straight mounting surface less
than 1 m long and 1 m wide
Allowed
Not allowed
Note the following for straight mounting
surface less than 1 m long and 1 m wide:
f
Observe chapter „Rooms with
slanted ceilings (slope angle > 20°)“
on page 55).
4.4 Rooms with a platform or gallery
0,5
1/2
0,5
0,5
>16 m
²
/
>2 m
1/2
Fig. 19 Rooms with a platform or gallery
Allowed
Not allowed
Note the following for rooms with plat-
forms or galleries (area greater than
16 m
2
, at least 2 m long and wide):
f
Mount additional device under the
platform / gallery.
5 Installation
•
Easy to maintain and removable ac-
cording to EN 14604:2005/AC:2008
•
or maintenance-unfriendly but
theft-proof according to
EN 14604:2005/AC:2008
and vfdb 14/01 (Q)
Adhesive mounting according to
EN 14604:2005/AC:2008
When performing this type of installation,
proceed as follows:
(1)
Remove magnetic carrier from the
device. (Remove the splint from the
activation button only after that)
f
To do this, tilt the magnetic carrier.
(2)
Remove the protective film from the
adhesive pad on the magnetic carrier.
The device is held by a magnetic carrier
at the installation location. The magnetic
carrier can be mounted by gluing or drill-
ing. It is imperative to observe the instruc-
tions in this manual and the general safety
instructions in order to prevent injuries
caused by incorrect installation.
CAUTION
Possible property damage!
Using other fastening material (not
enclosed) or wrong conditions at the
installation location can cause the
device to fall down.
f
Use only the supplied mounting material
(adhesive pad or screws /dowels).
f
Ensure that the mounting location is
strong enough, solid, dry, free from
grease, dust and loose paint etc.
f
Note that the magnetic carrier
magnetically attracts only from one side.
5.1 Adhesive mounting
The magnetic carrier can be mounted us-
ing adhesive assembly as follows: