Pyroclassic Fires Installation Instructions | Updated June 2017 | 3
POWDER COATED PANELS
Insert the side panels before the front and rear panels. The front and rear panel are supplied
either inside the fire chamber or on the lower heat shield behind the side panels.
Note: Please ensure that the Powdercoated screens, panels and corner strips are wiped clean
of any fingerprints etc. before the fire is used.
FIXING FLUE TO THE FIRE
Please use screw provided to attach flue to fire spigot.
Please do not use a rivet as this makes it quite difficult to easily remove the flue from fire for
cleaning. Sealant is not required as this joint has a 105mm restrictor hole. If sealant must be
used, apply sparingly to inside of spigot to avoid sealant overflowing.
UNPROTECTED WALLS
Minimum unscreened clearances are 350mm from the back of the Pyroclassic fire to the wall
and 480mm from the side of the fire to any side wall. For a corner installation with the
Pyroclassic angled at 45 degrees to the wall the minimum unscreened clearance from the walls
is 370mm, measured from the rear corners of the heater to the wall.
PYROCLASSIC STANDARD WALL SCREEN
Please see ‘
Pyroclassic Fires Wall Screen Installation Instructions’
provided with your wall
screen or online at
http://www.pyroclassic.co.nz/resources/downloads/
.
CORNER WALL SCREENS
Please see ‘
Pyroclassic Fires Wall Screen Installation Instructions’
provided with your wall
screen or online at
http://www.pyroclassic.co.nz/resources/downloads/
.
EARTHQUAKE RESTRAINTS
Two steel restraints that measure 50mm x 50mm with 2 8x20mm bolts which are supplied are
to be used when the Pyroclassic fire is not installed on the combination Hearth. These are
fitted to the two slots provided along the back plate of the Pyroclassic fire and then attached
to the floor with suitable fixings.
OPTIONAL WETBACK
See separate instructions which will be attached to your wetback or online at
http://www.pyroclassic.co.nz/resources/downloads/
.
WARNING: IF YOU HAVE NOT CONNECTED YOUR WETBACK TO
YOUR WATER CYLINDER-
DO NOT LIGHT THE FIRE