Summary of Contents for UVHB26

Page 1: ...ury or loss of life FOR YOUR SAFETY Installation and service must be performed by a qualified in staller service agency or the gas supplier Do not store or use gasoline or other flammable vapors and l...

Page 2: ...ONTENTS General Information 3 Specifications 4 Heater Installation 6 Parts 10 8 Log Installation 10 Operating Instructions 11 Maintenance 13 Troubleshooting Honeywell VS8421 15 Accessories 16 Replacem...

Page 3: ...sional service person should be contacted to inspect this heater annually PYROMASTER UVHB26 Vent Free Heaters Make it a practice to have all of your gas heaters checked annually More frequent cleaning...

Page 4: ...MANTEL FPS1212 FP21214 BRASS TRIM TOP BRASS TRIM BOTTOM HEARTH BASE 3 4 MOUNTING TABS HEARTH BASE TOP VIEW FP729 Fig 1 UVHB26 Series specifications UVHB26 Series Gas Appliance I I 26 5 1 I 39 625 I r...

Page 5: ...supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psig 3 45 kPa Table 1 Gas supply pressures HIGH ELEVATION DERATING Input ratings are shown in BTU per...

Page 6: ...26 heater in place 2 Place the heater on the hearth base centering side to side and 3 4 from the back edge of the hearth base See Fig 1 3 Bend the lower mounting tabs down against the hearth base and...

Page 7: ...an approved flex connector then reduced to 3 8 to the heater Because some municipalities have some additional local codes it is always best to consult your local authority Consult the current Nationa...

Page 8: ...from the fan control box NOTE These leads were hooked to the motor earlier 11 Mount the thermo disc to the shield under the burner pan and secure with two 2 nuts 12 Mount the fan on off control to the...

Page 9: ...wall receptacle box 2 Attach wire to switch and install switch into receptacle box Attach cover plate to switch J J 3 Connect wiring to gas valve Loosen the screws remove jumper as shown in Fig 7 Inst...

Page 10: ...osite end in the groove in the back of the front log D 9 ROCK PLACEMENT 1 lava Rock The lava rock provided withthis heater must be placed on the wire screen inthe center of the burner tube Place just...

Page 11: ...nd will settle on the floor IF YOU SMELL GAS 1 Do not try to light any appliance 2 Do not touch electrical switches do not use any phone in your building 3 Immediately call your gas supplier from a ne...

Page 12: ...7 If the knob does not pop out when re leased stop and call your service techni cian or gas supplier If the gas pilot will not stay lit after several tries turn the gas control knob OFF and call your...

Page 13: ...gas orifice thermopile combination millivolt gas valve Most of these components may require only an occasional checkup and cleaning and some may require adjustment If repair is necessary it should be...

Page 14: ...ated near the center of the gas control See Figure 13 A It is important to periodically perform a visual check of the pilot and the burner flames See Figures 12 and 14 Turn clockwise to increase flame...

Page 15: ...IGNITOR PILOT LIGHTS WITH I NO PIElO IGNITOR YES PILOT STAYS LIT NO FOR AIR IN THE LINES THERMOPILE NEEDS A MINIMUM325mV ADJUST PILOT FLAME HEIGHT ALLWIRING CONNECTIONS REPLACE THERMOPILE THERMOCOUPL...

Page 16: ...IES UVHB26 CAUTION This heater is a highly engineered system and as such must be oper ated only with PYROMASTER approved components If you use an unapproved component to make any modifications you may...

Page 17: ...h 1 j PYROMASTER UVHB26 Vent Free Heaters UVUB26 REPLACEMENT PARTS 7 I I S II f I 12 6a1b if 18 s I I 4a 9 17 c 10 14 ii f o 11 d 1 16 15 13 1a f1 f 1b 2a1b 3a b FP736 17...

Page 18: ...30 3a Pilot Assembly NAT 55464 3b Pilot Assembly LP 55465 4a Screen Assembly 3187170 Sa Burner Tube Assembly NAT 3187171 5b Burner Tube Assembly LP 6a Orifice NAT 7535197 6b Orifice LP 7535164 7 Top T...

Page 19: ...CFM Corporation 2695 Meadowvale Boulevard Mississauga Ontario L5N 8A3 Canada 800 668 5323 www cfmcorp com...

Page 20: ...Y CONSTRUCTION INSTALLA TION LABOR TRANSPORTATION OR OTHER COSTS OR EXPENSES ARISING FROM A DEFECTIVE PART ITS REPAIR OR REPLACEMENT OR OTHERWISE NOR SHALL CFM HARRIS SYSTEMS INC IN ANY EVENT BE RESPO...