Atlas 4 End Of Line Resistor Wiring Diagrams
Wiring unused zones.
Wiring two or more sensors with end of line resistors to a single zone.
NOTE:
only one 2K2 resistor should be used per zone. The 2k2 resistor should be installed in the last detector in series
to protect all the zone tamper wiring.
Up to ten sensors or door contacts may be wired on each zone.
9.8 Telephone
Connections
9.9
Powering Up The Panel and RKP
a.
Connect the battery leads to the control panel. (+BAT-). The red lead should be connected to "
+
" terminal
and the black lead to "
-
" terminal.
b.
Push on the spade connectors to connect the battery
c.
Switch on the AC supply. The supply LED will be on. Now proceed to Section 10 "Programming".