3 ACCESS 

LEVELS

   

 

 

 

 

 

 

3.1 User 

Codes 

(Codes 3 to 7) 

 

1. Panel setting and unsetting with a unique pass code. 

 

 

 

 

 

 

2. Setting and unsetting of the door chime facility. 

      3. 

Event 

log 

viewing. 

 
3.2 

Master & Manager Codes

 All User facilities plus 

 

(

Master Code 1, Manager Code 2)

   

4. Clearing of event log (if allowed by the Engineer).

 

5. Changing the User codes, (the Manager cannot alter the Master  
User Code). 

      6. 

LED 

Strobe 

Bell 

/ Extension Speaker test facility.

 

 

 

 

 

 

 

7. Walk test facility for all four set modes. 

 

 

 

 

 

 

8

. Remote Dial in enabling.

 

 
3.3 Engineer 

 

 

 

All facilities except setting / unsetting the system unless user code known. 

 

 

 

 

 

 

9. Zone programming for all four set modes. 

      10. 

Bell 

timer 

setting. 

      11. 

Entry 

Exit 

timer 

settings. 

      12. 

Alteration 

of 

Engineer 

code. 

      13. 

Enabling 

or 

Disabling 

of Event log reset by Master user. 

14. Programming of communication and programmable output  
      options. 
15. Engineer NVM Reset. 

 

Page 10 

Summary of Contents for ATLAS 8 PLUS

Page 1: ...pad Pyronix Limited October 2001 This Product is approved for use in the Residential Commercial and Light Industrial Environment ATLAS 8 PLUS 8 A B C D 2 1 3 4 SET 5 6 7 8 9 0 INSTALLER DETAILS TELEPH...

Page 2: ...com This is a premium rate line where calls are charged at 50p per minute uk sales pyronix com WARRANTY This product is sold subject to our standard warranty conditions and is warranted against defect...

Page 3: ...Negative Removed Tamper 22 10 10 Shock Sensors 22 10 11 Double End of Line Resistor 23 10 11 1 Wiring Unused Zones in Double End Of Line 23 10 11 2 Wiring Two or More Sensors With End Of Line Resisto...

Page 4: ...cation 35 11 11 22 Engineer NVM Reset 35 11 11 23 Follow Select 35 11 11 24 Bell Delay 36 11 11 25 Anti Code First Digit 36 11 11 26 Engineers P C Third Telephone Number 36 11 11 27 System Option 5 36...

Page 5: ...46 12 11 15 User Set Reporting Codes 46 12 11 16 User Unset Reporting Codes 47 12 11 17 Maintenance and Priority Codes 47 12 11 18 Restoral Reporting Codes 47 12 11 19 Digicom Codes 47 12 11 20 Keyswi...

Page 6: ...CHNICAL SPECIFICATION 54 13 1 Power supply 54 13 2 Control PCB 54 13 3 Mechanical 54 13 4 Environmental 54 13 5 Cleaning 54 14 ENGINEER QUICK REFERENCE PROGRAMMING 55 15 COMMUNICATION PROGRAMMING 57 A...

Page 7: ...tting facilities but also allows the changing of code numbers except the Master User Code and testing of the system The Master User level gives access to all setting and unsetting facilities but also...

Page 8: ...ring all cables should be tied together to prevent any possibility of a loose wire causing a safety hazard 7 There are no user serviceable parts inside For continued protection against the risk of fir...

Page 9: ...Rins163 Issue 9 Page 9...

Page 10: ...Manager cannot alter the Master User Code 6 LED Strobe Bell Extension Speaker test facility 7 Walk test facility for all four set modes 8 Remote Dial in enabling 3 3 Engineer All facilities except se...

Page 11: ...the ability at the programming stage to configure all the circuits to the customer s exact requirements 4 2 Entry Exit Mode Entry When the panel is set and an Entry Exit zone is triggered the Entry ti...

Page 12: ...nd which is easily distinguished from all other tones The external sounder will operate at 1 second intervals NOTE The Fire Zone is intended as an extra feature to the intruder alarm system and must n...

Page 13: ...feature allows the user to either set or unset the alarm with the last two digits of the code reversed this will then send a duress code to the alarm receiving centre The panel will appear normal when...

Page 14: ...y 24 hours Dial In This option will allow the panel to respond to an incoming call in Answer Machine Compatible mode for uploading downloading of programming information Answer Machine Compatible mode...

Page 15: ...ans of identifying the system can set the first digit of the anti code Open Zone When enabled and the panel is unset any entry exit access or immediate zones will be displayed at the keypad Alarm on l...

Page 16: ...rted system faults are bell fuse failure auxiliary fuse failure battery missing low battery voltage mains failure line failure PC and line failure Digi System Option 21 The system may be configured fo...

Page 17: ...odes After an alarm activation one of two restoral reporting codes maybe logged User Code Restoral This code will be logged when the system has been reset 2 nd user code engineer code or anti code aft...

Page 18: ...lly Plan out the various areas and degrees of protection required from each zone It is important to decide which type each zone should be if selective sets are to be used Work out the cable routes avo...

Page 19: ...Rins163 Issue 9 Page 19...

Page 20: ...in place Cut out the battery support posts and install into the cut outs as shown depending upon the size of the battery 9A 2 Speaker Assembly Remove the speaker back cover If the internal speaker is...

Page 21: ...le the tamper switch from the optional kit of parts as indicated If necessary place the transformer and fasten into position using the screws supplied with the transformer kit Wall Mounting 9B Panel A...

Page 22: ...taminated area for the head of the earthing grounding screw 2 Mount the terminal block on the metalwork 3 Carry out a high current less than 25Amps resistance check between the metal work and the Eart...

Page 23: ...t a battery back up is required Refer to 10 5 for battery specifications Connect the battery to the terminals marked BAT on the PCB 10 3 Bell Strobe and Extension Speaker Connections Strobe Positive S...

Page 24: ...The two outer connections should be used for tamper feed and return and the middle connections used for tamper loop 10 9 Tamper Connection for Bell Box s with Negative Removed Tamper Bell Box Negative...

Page 25: ...Rins163 Issue 9 Page 25...

Page 26: ...ired using end of line resistors to enable the zone to detect alarm and tamper the system must be configured in System Option 1 Refer to Page 25 10 11 1 Wiring Unused Zones In Double End Of Line 2K2 R...

Page 27: ...Typical current for external strobe 8 hours 150mA 0 15 A Alarm condition for 20 mins 0 333 hrs Alarm state current for control panel 0 130 8 detectors 15mA 0 120 External sounder 0 350 External strob...

Page 28: ...eaker P A Switch Contacts Tamper Switch Contacts RJ11 Telephone Socket Digicoms 2K2 2K2 2K2 2K2 Unused Zones Telephone Network Internal System Remote Keypad RESET 10 15 Atlas End of Line Wiring Diagra...

Page 29: ...BATTERY Extension Speaker Digicoms Unused Zones Telephone Network Internal System P A Remote Keypad RESET 10 16 Atlas Double Pole Wiring Diagram T SPARE T T T N C TAMPER ALARM SUPPLY PIR Panel Tamper...

Page 30: ...acts Tamper Switch Contacts RJ11 Telephone Socket 2K2 Digicoms 2K2 2K2 2K2 2K2 Unused Zones Telephone Network Internal System RESET 10 17 Atlas End of Line Wiring Diagram With Negative Tamper Return T...

Page 31: ...3 Engineer Power Up NVM Reset Engineer System Reset Disabled User Omit Enabled Door Chime On Push To Set Enabled System Option 4 Anti Code Reset Disabled Open zone display Disabled No alarm on line fa...

Page 32: ...ill operate at full volume NOTE Each RKP has its own volume control pot 11 4 Resetting the Non Volatile Memory NVM to Factory Settings The panel may be programmed as power up NVM reset or engineer cod...

Page 33: ...Atlas is factory set to 20 minutes 11 8 Setting Entry Time To set the required Entry time Enter followed by the time required in seconds to seconds followed by Incorrect entry gives an audible error...

Page 34: ...mbered keys are pressed Key Press Display Alarm Tamper P A Fire ON 7 Day test dial Dial in BSIA test dial Silent P A zones OFF 24 Hour test dial No dial in No BSIA test dial Audible P A zone Enter to...

Page 35: ...stomer Account Code Issued by Central Monitoring Station Enter followed by the 4 digit code To use hex codes use the up key to select the character required and the key to accept 11 11 11 Downloading...

Page 36: ...or both digits To use hex codes use the up key to select the character required and the key to accept Example Set A Set B Set C Set C Duress Set Duress Unset Confirmed Alarm Code Reporting codes are a...

Page 37: ...Rins163 Issue 9 Page 37...

Page 38: ...ey to select the character required and the key to accept Example P A alarm entered at RKP Fire alarm entered at RKP Engineer mode entered Bell fuse failure Auxiliary fuse failure Battery trouble AC f...

Page 39: ...oth telephone numbers always After a number has been selected the next group will be automatically selected Group 2 User Set Unset Codes Select from the list above where you require User Set Unset cod...

Page 40: ...ccept 11 11 28 System Option 6 Enter followed by The RKP LED will toggle on and off as the numbered keys are pressed Key Press Display Alarm Tamper P A Fire ON Abort digi active high Open digi active...

Page 41: ...numbered keys are pressed Key Press Display Alarm Tamper P A Fire ON Alarm On P A On Fire On Confirmed Alarm On OFF Alarm Off P A Off Fire Off Confirmed Alarm Off Enter to accept 11 11 34 System Optio...

Page 42: ...Unset On System Fault On Spare OFF Abort Off Set Unset Off System Fault Off Spare Enter to accept 11 11 39 System Option 17 Set C Send Options Enter followed by The RKP LED will toggle on and off as...

Page 43: ...Reset omit Global Tamper Negative Return Disable telephone line monitoring X All resets No reset omit Global Tamper Volt Free Loop Enable telephone line monitoring Enter to accept 11 11 44 Set A Set O...

Page 44: ...re are 8 fault conditions automatically detected by the Atlas The user is informed of a fault via the fault LED This will illuminate and an error tone will be emitted every 5 seconds when the panel is...

Page 45: ...Rins163 Issue 9 Page 45...

Page 46: ...Engineer Power Up NVM Reset Engineer System Reset Disabled User Omit Enabled Door Chime On Push To Set Enabled System Option 4 Anti Code Reset Disabled Open Zone Display Disabled No Alarm on Line Fail...

Page 47: ...Rins163 Issue 9 Page 47...

Page 48: ...speakers will operate at full volume NOTE Each RKP has its own volume control pot 12 4 Resetting the Non Volatile Memory NVM to Factory Settings The panel may be programmed as power up NVM reset or e...

Page 49: ...wed by the required time in minutes to minutes followed by Incorrect entry gives an audible error tone and correct entry gives three bleeps The alarm bell cut off time for the Atlas is factory set to...

Page 50: ...followed by The RKP will toggle and X as the numbered keys are pressed Key Press Display 1 2 3 4 Double pole zone User log reset enabled External and extension speaker on tamper activation X End of l...

Page 51: ...he a is displayed to cause a 2 second pause during dial out Press to store entry A number consisting of 16 digits will be stored automatically when the last digit is entered 12 11 10 Customer Account...

Page 52: ...des To disable an event insert blanks for both digits To use hex codes use the up key to select the character required and the key to accept Example Set A Set B Set C Set C Duress Set Duress Unset Con...

Page 53: ...t the character required and the key to accept Example P A alarm entered at RKP Fire alarm entered at RKP Engineer mode entered Bell fuse failure Auxiliary fuse failure Battery trouble AC fail Global...

Page 54: ...up will be automatically selected Group 2 User Set Unset Codes Select from the list above where you require User Set Unset codes to be reported to Group 3 Maintenance Codes Select from the list above...

Page 55: ...followed by The RKP will toggle and X as the numbered keys are pressed Key Press Display 1 2 3 4 Abort digi active high Digi active high Duress Off Wide handshake filters X Abort digi active Low Open...

Page 56: ...owed by The RKP will toggle and X as the numbered keys are pressed Key Press Display 1 2 3 4 Alarm On P A On Fire On Confirmed Alarm On X Alarm Off P A Off Fire Off Confirmed Alarm Off Enter to accept...

Page 57: ...On System Fault On Spare X Abort Off Set Unset Off System Fault Off Spare Enter to accept 12 11 39 System Option 17 Set C Send Options Enter followed by The RKP will toggle and X as the numbered keys...

Page 58: ...tive Return Disable telephone line monitoring X All resets No reset omit Global Tamper Volt Free Loop Enable telephone line monitoring Enter to accept 12 11 44 Set A Set Option Enter Enter for timed e...

Page 59: ...been assigned three letters of the alphabet by pressing the key several times the number and letter sequence will be scrolled through To insert spaces between text press the key twice When the desired...

Page 60: ...r load 16 to 32 Ohms Bell 500mA Strobe 500mA PR1 PR2 250mA Alarm bell time 2 to 20 minutes software programmable Zone type Normally closed loops which activate when opened or short circuit Zone loop c...

Page 61: ...cond Telephone Number Customer Account Code Uploading Downloading Access Code Zone Alarming Reporting Codes Zone Tamper Reporting Codes System Set Unset Reporting Codes User Set Reporting Codes User U...

Page 62: ...11 System Option 12 System Option 13 System Option 14 System Option 15 System Option 16 System Option 17 System Option 18 System Option 19 System Option 20 System Option 21 Set A Set Option Set B Set...

Page 63: ...Omit Enabled 4 Default Door Chime On PTS Enabled System Option 4 1 Default Anti Code Reset Disabled 2 Display Open Zones Off 3 No Alarm On Line Fail STU 4 No Alarm On Line Fail PC System Option 5 1 De...

Page 64: ...3 Fire On 4 Confirmed Alarm Off System Option 16 1 Abort Alarm On 2 Set Unset Off 3 System Faults Off 4 Spare System Option 17 1 Alarm Off 2 P A On 3 Fire On 4 Confirmed Alarm Off System Option 18 1...

Page 65: ...e 2 Alarm Zone 3 Alarm Zone 4 Alarm Zone 5 Alarm Zone 6 Alarm Zone 7 Alarm Zone 8 Alarm Tamper Alarm Reporting Codes Zone 1 Tamper Zone 1 Tamper Zone 1 Tamper Zone 1 Tamper Zone 1 Tamper Zone 1 Tamper...

Page 66: ...er 6 Set User 7 Keyswitch User Unset Reporting Codes Unset User 1 Unset User 2 Unset User 3 Unset User 4 Unset User 5 Unset User 6 Unset User 7 Keyswitch Maintenance and Priority Codes P A Key Fire Ke...

Page 67: ...n Line Fail on board comms Restoral Line Fail stu Restoral Full Power Up Restoral Miscellaneous Reporting Codes On board comms line fail Off board stu line fail Digicom Format Keyswitch Set Configurat...

Page 68: ...ATLAS 8 PLUS SERVICE HISTORY Page 68...

Page 69: ...Rins163 Issue 9 Page 69...

Reviews: