Alarm Receiving Centre Second Telephone Number:
This is an alternative number which will be used by the Atlas if the first telephone line is
busy. If after four attempts connection with the first number fails then this number will be
dialled.
Engineers Third Telephone Number:
If a telephone number is programmed here it will be dialled when
is pressed and
initiate an up / downloading session.
Customer Account Code: This is a four digit number given to the installation engineer by the alarm receiving centre.
The number identifies the customer site when the panel dials out during an alarm activation.
The upper Hex digits (B to F) can be used.
Downloading Access Code: This is a four digit access code required by the alarm company in order to access the panel
during an uploading / downloading operation.
Reporting Codes:
These are unique two digit codes used by the central monitoring station to identify the zone
causing an alarm activation and to give information on the status of the Atlas. These codes
are issued by the central monitoring station and are dialled out by the Atlas when
programmed to do so. The upper Hex digits (B to F) can be used.
Restoral Reporting Codes: After an alarm activation one of two restoral reporting codes maybe logged.
User Code Restoral:
This code will be logged when the system has been reset (2
nd
user code, engineer code or
anti code) after an alarm activation.
Bell Time-out Restoral:
If after the external sounder has timed out the panel is automatically re-set then the bell
time-out restoral code will be logged.
Battery Restoral:
This code will be reported when a battery fault is restored after a failure.
A.C. Restoral:
This code will be transmitted upon restoral of AC power.
Line Fail Restoral PC:
This code will be transmitted upon restoral of the on board comms line.
Line Fail Restoral Digi:
This code will be transmitted upon restoral of the off board stu (external comms) line.
Power Up Restoral:
This code will be sent when the battery and a.c power is restored to the panel.
Digicom Codes:
The Atlas may be programmed to output its communicator codes in one of six different
formats. SIA DTMF format is the default. Check with your central monitoring station for the
required format. The Atlas may be programmed to report the 4 + 2 events via the onboard
serial link at 9600bps.
Keyswitch Set Configuration:
Any of the Atlas alarm zones may be programmed as a keyswitch zone. The keyswitch may
be configured to set the panel as Set A, B, C or D. (see programming section for details).
Rins163 Issue 9
Page 17
Summary of Contents for ATLAS 8 PLUS
Page 9: ...Rins163 Issue 9 Page 9...
Page 19: ...Rins163 Issue 9 Page 19...
Page 25: ...Rins163 Issue 9 Page 25...
Page 37: ...Rins163 Issue 9 Page 37...
Page 45: ...Rins163 Issue 9 Page 45...
Page 47: ...Rins163 Issue 9 Page 47...
Page 68: ...ATLAS 8 PLUS SERVICE HISTORY Page 68...
Page 69: ...Rins163 Issue 9 Page 69...