System
Faults
Off
System Option 17
: Alarm Off
P.A.
On
Fire
On
Confirmed
Alarm
Off
System Option 18
: Abort Alarm On
Set / Unset Off
System
Faults
Off
System Option 19
: Alarm Off
P.A.
On
Fire
On
Confirmed
Alarm
Off
System Option 20
: Abort Alarm On
Set / Unset Off
System
Faults
Off
System Option 21
: All resets
No
Reset
omit
Global Tamper Volt Free Loop
Telephone line monitoring Enabled
Programmable Re-sets
: 1
The following key applies to the table below:
Entry / Exit
=
E
Access
=
A
Immediate =
I
The zone types are factory set as follows.
Zone
Number
1 2 3 4 5 6 7 8
Set A
E a I I I I I I
Set B
e a I I I I I I
Set C
e a I I I I I I
Set D
e a I I I I I i
11.2
Entering Engineer Mode
Enter
Engineer mode will be indicated by a flashing fault LED.
Whilst in Engineer mode, you are able to remove any covers without creating a tamper alarm.
11.3
Setting Volume Control (Extension speaker only)
This volume is controlled via the adjustable volume pot on the main processor board.
1. Remove lid.
2. Set volume pot to desired volume (Clockwise Decrease & Anti Clockwise Increase)
3. Replace cover.
In an alarm condition the volume control is overridden and the speakers will operate at full volume.
NOTE
: Each RKP has its own volume control pot.
11.4
Resetting the Non Volatile Memory (NVM) to Factory Settings
The panel may be programmed as power up NVM reset or engineer code only NVM reset.
Engineer Power Up NVM Reset
If the panel is configured by the engineer to allow the reset of the NVM back to factory settings by powering up the
system with the NVM reset pins shorted together.
Locate the NVM reset pins on the PCB, using the link pin provided connect the two pins together. Power down the
system (mains and battery). Restore power and remove the link. The system is now back to factory default settings.
(N.B) 3 tones will be heard on power up and a further 3 beeps after for 10 seconds.
Engineer Only NVM Reset
Enter the engineer mode. Use the link supplied to connect the NVM reset pins together and enter
on the
key pad. 3 Bleeps will be heard then a further 3 bleeps after 5 seconds. The system is now back to factory default
settings.
11.5
Setting the Panel when Mains Fails
Under normal operation the panel will indicate a fault condition if the AC supply is disconnected. It will still be possible to
Set and Unset the control panel during a mains fail and no further action is required.
Full functionality of the control panel is available during mains fail providing the system is battery backed.
Page 32
Summary of Contents for ATLAS 8 PLUS
Page 9: ...Rins163 Issue 9 Page 9...
Page 19: ...Rins163 Issue 9 Page 19...
Page 25: ...Rins163 Issue 9 Page 25...
Page 37: ...Rins163 Issue 9 Page 37...
Page 45: ...Rins163 Issue 9 Page 45...
Page 47: ...Rins163 Issue 9 Page 47...
Page 68: ...ATLAS 8 PLUS SERVICE HISTORY Page 68...
Page 69: ...Rins163 Issue 9 Page 69...