12.11.48 Final Door
Enter
followed by the time required in seconds (
to
seconds) followed by
.
Incorrect entry gives an audible error tone and correct entry gives three bleeps. Final door delay is factory
set to seven seconds. If the exit door is reopened the delay is reset and the countdown commences when
the exit door is finally closed.
12.11.49 Change Text
To change the display text.
Press the
key. Use the down scroll key to display
‘change text’
and press the
key to accept.
‘
User 1’
will now be displayed, use the scroll keys to display the change text options. When the required user, zone or
label is displayed the text can be changed by using the number keys 1 to 9. Each key has been assigned three letters of
the alphabet, by pressing the key several times the number and letter sequence will be scrolled through. To insert
spaces between text press the
key twice. When the desired letter or number is displayed use the
and
scroll keys to move between segments on the display and when the text is complete press the
key to accept.
The
key must be pressed or the text changes will not be accepted.
To exit ‘
change text’
press the
key.
11.11.50 Exiting Engineer Mode
Enter
(Where
is the 4 digit Engineer Code).
12.11.51 SYSTEM FAULTS
There are 8 fault conditions automatically detected by the Atlas. The user is informed of the actual fault on the LCD
keypad display, and an error tone will be emitted every 5 seconds when the panel is in day mode, press the
key to
stop the error tone. The fault be displayed until the fault has been corrected.
Rins163 Issue 9
Page 59
Summary of Contents for ATLAS 8 PLUS
Page 9: ...Rins163 Issue 9 Page 9...
Page 19: ...Rins163 Issue 9 Page 19...
Page 25: ...Rins163 Issue 9 Page 25...
Page 37: ...Rins163 Issue 9 Page 37...
Page 45: ...Rins163 Issue 9 Page 45...
Page 47: ...Rins163 Issue 9 Page 47...
Page 68: ...ATLAS 8 PLUS SERVICE HISTORY Page 68...
Page 69: ...Rins163 Issue 9 Page 69...