Page 16
10.6.2
Atlas 8 Double Pole Zone Wiring Diagram.
Wiring two or more sensors with end of line resistors to a single zone.
NOTE:
only one 2K2 resistor should be used per zone
. The 2K2 resistor should be installed into the last detector in
series to protect all the zone tamper wiring.
Up to ten sensors or door contacts may be wired on each zone.
10.7 Telephone
Connections
T - 1 R - 1 TIP RIN G
10.8
Powering Up Your Panel / RKP
a.
Connect the battery leads to the control panel. (+BAT-). The red lead should be connected to "
+
" terminal
and the black lead to "
-
" terminal.
b.
Push on the spade connectors to connect the battery
c.
Switch on the AC supply. The supply LED will be on. Now proceed to Section 11 "Programming".
Summary of Contents for BUMBT!8
Page 34: ...Page 34 ...
Page 35: ...Rins 181 Issue7 Page 35 ...