Rins 181 Issue7
Page 21
11.10
Changing the Engineer Code
Enter
then
The old Engineer Code - gives an audible acceptance tone
(Factory Set at 9999)
then
the new Engineer Code - gives an audible acceptance tone
then
the new Engineer Code again- gives an audible acceptance tone
If an incorrect key is entered an error tone will be given and the function ended.
11.11 Programmable
Outputs
11.11.1 Programmable Output 1
Enter
followed by
-
for following options:
0
OFF (programmable output 1 not used).
1
PIR
remote
LED
enable.
2
PIR
latch
memory.
3
Output
switch
5
secs.
4
Output switch reflecting setting and unsetting of panel.
5
Follow zone. Refer to 11.1121 for Zone allocation.
6
Follow
line
fail.
7
Follow
kiss
off.
11.11.2 Programmable Output 2
Enter
followed by
-
for following options:
0
OFF (programmable output 2 not used).
1
PIR
remote
LED
enable.
2
PIR
latch
memory.
3
Output
switch
5
secs.
4
Output switch reflecting setting and unsetting of panel.
5
Follow zone. Refer to 11.11.22 for Zone allocation.
6
Follow
line
fail.
7
Follow
kiss
off.
Summary of Contents for BUMBT!8