W
ALL
F
URNACE WITH
P
OWER
F
LUE
Page 4
Operating the Unit
Unit Operation
This appliance is not intended for use by young children or infirm persons unless they have
been adequately supervised by a responsible person to ensure that they can use the appliance
safely.
Young children should be supervised to ensure they do not play with the appliance.
Start-Up Sequence
1. Before starting ensure the protective membrane has been
removed from the control decal.
2. Press the ON / OFF button.
3. The heater will start in the Manual mode of operation. In
approximately 45 seconds the gas valve will open and the
ignitor will function. Ignition will commence on a high gas
rate.
4. Within 5 seconds of ignition the flame sensor will prove the
flame.
5. Within another 30 seconds the fan will operate on low fan
speed.
6. The Gas Valve Level and Fan Speed can be adjusted to
desired point.
7. Alternatively the heater can be set to Automatic mode.
The gas valve will now modulate according to the
sensing of the room thermistor.
Once the heater has reached the set temperature, the
flame will extinguish and the fan will continue to run for
at least one minute.
Once the room temperature drops approximately 2
o
C,
the heating sequence will restart.
U
SING THE
C
ONTROLS
The user interface consists of a display, a top push button for turning the unit on and off and four other
push buttons. The other push buttons are named SELECT, MODE, UP and DOWN. There is also a
buzzer that emits a short beep for valid user action and a longer beep for invalid user actions.
The wall fur nace us er inter fac e c onsists of a displ ay, a pus h but ton for tur ning t he unit on and off and four t ouch but tons. The touc h butt ons ar e named s elec t, mode, up and down. T here is als o a buzzer that emit s a s hort beep f or vali d us er ac tion and a l ong er beep f or invalid us er action