2 PLANNING

2.3  Mounting options

2 PLANNING

2.3  Mounting options

Specifications

 

MODULE TYPE

MOUNTING 
OPTION

CLAMPING AREA

1

 [MM]

ALLOWED STATIC 
LOAD² [PA]

TEST LOAD ACC. 
IEC 61215  
PUSH/PULL [PA]

B.LINE PLUS S-G4.X

B.LINE PEAK S-G4.X

CL1

Push

150 - 350

2700

5400/4000

Pull

150 - 350

2400

CL1 extended 

(min. 20 mm)

Push

150 - 350

3600

Pull

150 - 350

2400

CL3

Push

150 - 350

3300

5400/4000

Pull

150 - 350

2400

FB1

Push

274

2900

5400/4000

Pull

274

2800

FB2

Push

274

3200

5400/4000

Pull

274

2800

IP1

Push

-

3200

5400/4000

Pull

-

3000

IP2

Push

-

1350

2400/2400

Pull

-

1200

CL2 without 

substructure 

support

Push

0 - 100

1300

2400/2400

Pull

0 - 100

1200

CL4

Push

0 - 300

1350

2400/2400

Pull

0 - 300

1200

1

 Distance between outer edge of module and middle of the clamp. 

² Describes the maximum module surface load (vertical to the module surface) regarding safety factors (e.g. EUROCODE). For 
this purpose, the load value determined by load tests according to various criteria: laminate overlay, plastic deformation, module 
failure, and were divided with a safety factor. The minimum calculated load value corresponds to the maximum permitted load.

MOUNTING OPTION CL1

 

Ä

Ensure, that the subconstruction does not run below the junction box.

 

Ä

Ensure, that the connection cables of the junction box don‘t run between laminate and substructure.

MOUNTING OPTION CL1 EXTENDED

 

Ä

Ensure, that there’s distance of minimum 45 mm between laminate backside and subconstruction respectively  
that the distance between module frame backside and substructure is minimum 20 mm.

 

Ä

Ensure, that the connection cables of the junction box don‘t run between laminate and substructure.

MOUNTING OPTION CL4

 

Ä

Ensure, that the subconstruction runs exactly below the frame, not below the laminate (module less frame).

MOUNTING OPTIONS FB1 AND FB2

 

Ä

Ensure, that the connection cables of the junction box don‘t run between laminate and substructure.

• 

Use M8 corrosion-proof screws and washers (min. diameter 16 mm).

Specifications

 

MODULE TYPE

MOUNTING 
OPTION

CLAMPING AREA

1

 [MM]

ALLOWED STA-
TIC LOAD² [PA]

TEST LOAD ACC.  
IEC 61215  
PUSH/PULL [PA] 

B.LINE PRO-G4.X

B.LINE PRO BFR-G4.X 

B.LINE PLUS-G4.X

B.LINE PEAK-G4.X

B.LINE PEAK BLK-G4.X

CL1

Push

250 - 350

2700

5400/4000

>350 - 450

1900

Pull

250 - 450

2400

CL1 extended 

(min. 20 mm)

Push

250 - 350

3600

>350 - 450

3300

Pull

250 - 450

2400

CL3

Push

250 - 450

3300

5400/4000

Pull

250 - 450

2400

CL4

Push

0 - 300

1350

2400/2400

Pull

0 - 300

1200

FB1

Push

345

2200

5400/4000

Pull

345

2800

FB2

Push

345

3200

5400/4000

Pull

345

2800

IP1

Push

-

3200

5400/4000

Pull

-

3000

IP2

Push

-

1350

2400/2400

Pull

-

1200

CL5 hybrid 

clamping

Push

300 - 400

2700

2400/2400

Pull

300 - 400

2700

CL2 without 

substructure 

support

Push

0 - 100

1300

2400/2400

Pull

0 - 100

1200

1

 Distance between outer edge of module and middle of the clamp. 

² Describes the maximum module surface load (vertical to the module surface) regarding safety factors (e.g. EUROCODE). For 
this purpose, the load value determined by load tests according to various criteria: laminate overlay, plastic deformation, module 
failure, and were divided with a safety factor. The minimum calculated load value corresponds to the maximum permitted load.

MOUNTING OPTION CL1

 

Ä

Ensure, that the subconstruction does not run below the junction box.

 

Ä

Ensure, that the connection cables of the junction box don‘t run between laminate and substructure.

MOUNTING OPTION CL1 EXTENDED

 

Ä

Ensure, that there’s distance of minimum 45 mm between laminate backside and subconstruction respectively  
that the distance between module frame backside and substructure is minimum 20 mm.

 

Ä

Ensure, that the connection cables of the junction box don‘t run between laminate and substructure.

MOUNTING OPTION CL4

 

Ä

Ensure, that the subconstruction runs exactly below the frame, not below the laminate (module less frame).

MOUNTING OPTIONS FB1 AND FB2

 

Ä

Ensure, that the connection cables of the junction box don‘t run between laminate and substructure.

• 

Use M8 corrosion-proof screws and washers (diameter 16 mm).

Summary of Contents for B.LINE G4

Page 1: ...Valid for Africa Asia Europe Latin America North America South America B LINE G4 SOLAR MODULES INSTALLATION AND OPERATION MANUAL...

Page 2: ...tions In particular the installer as well as the operator of a module is responsible for compliance with all applicable statutory requirements and regulations Unless otherwise specified by any laws or...

Page 3: ...ontext of contractual agreements or in the context of accepted guarantees Q CELLS accepts no other responsibility for the functionality and safety of the modules Please observe the instructions for an...

Page 4: ...es e g caused by vibrations twisting or expansion are generated on the module Ensure that the clamps and the mounting frame are compatible Clamp System Requirements Use customary clamps that satisfy t...

Page 5: ...ection cables of the junction box don t run between laminate and substructure Use M8 corrosion proof screws and washers min diameter 16 mm Specifications MODULE TYPE MOUNTING OPTION CLAMPING AREA1 MM...

Page 6: ...tors Sizing of control systems connected to the outlets of the solar modules Please follow the valid national guidelines for the installation of electrical systems Series Connection Connection of modu...

Page 7: ...the installation alone Only install undamaged modules and components Do not modify the module e g do not drill any additional holes 3 2 Preparation of installation 3 INSTALLATION NOTE Module damage ma...

Page 8: ...me caution Ensure that the modules are disconnected at the inverter prior to separation Be sure to observe the specified time intervals after switching off the inverter High voltage components need ti...

Page 9: ...due to electric shock Ensure that all electrical components are in a proper dry and safe condition Standard wiring with a return cable Inverter EN 4 3 Connection of modules 4 ELECTRICAL CONNECTION DA...

Page 10: ...ot attempt to fix any problems yourself e g glass cracks damaged cables Please contact an installer or Q CELLS Technical Customer Service Department 6 FAULTS AND DEFECTS Do not disconnect modules by y...

Page 11: ...alone or without taking adequate security precautions Please commission a trade specialist Clean the modules as follows NOTE Module surface damage may occur Remove snow and ice without force e g with...

Page 12: ...nenallee 17 21 06766 Bitterfeld Wolfen Germany TEL 49 0 34946699 23222 FAX 49 0 34946699 23000 EMAIL service q cells com WEB www q cells com Subject to change without notice Hanwha Q CELLS Installatio...

Reviews: