INSTALLATION AND OPERATION MANUAL FOR FLAT ROOF SYSTEM Q.FLAT-G6 – Q CELLS
PRELIMINARY WORK:
Î
Clean the roof surface and remove any obstructions;
Î
Measure roof surface and compare with project report;
Î
Mark system corner dimensions.
PROCEDURE:
Î
Lay out the components start and end profile
A
, base
C
,main base profile
B
, base
C
and connecting base profile
D
one be-
hind the other according to the project report. The order here is starting from east to west:
A
C
B
C
D
C
B
C
…
D
C
B
C
A
. The sequence is the same in every row and always ends at the end of the row with the start and end base
profile
A
.
Î
Push the profiles
A
,
C
,
B
,
C
and
D
into each other until the click latch engages with an audible noise (see Detail Figure 3).
Î
The snap-in connection is to be checked for clean form fit and strength.
Î
The base profile rows are now to be set up according to the spacing specified in the project (see
).
ATTENTION:
The base
C
must always face away from the main base profile
B
!
TIP:
The marking at the ends of the cross brace and ballast brace
F
indicates the exact removal of the main base profiles
B
.
A
A
C
C
C
C
B
B
x = 1840 / 1673
+ 20 mm
− 115 mm
All Q CELLS base profiles are fitted with 11 mm thick high-tech protective mats. The gaps between the protective mats ensure
free water drainage. The protective mats prevent damage to the roof covering due to mechanical impact and long-term damage
due to plasticiser migration. Furthermore, all profiles are equipped with drainage holes on the undersides to prevent water build-up
and frost damage.
INFO
i
4
ASSEMBLY
4.1 LAY OUT, CONNECT AND SET UP MAIN BASE
PROFILES A, B, D AND BASE C.
D
4
x
3
CLICK!
A
B
2
A
B
C
1
NOTE:
The size / variant of the connecting base profile
D
can always be found in the current project report. Incorrectly installed
components such as bases
C
that have to be removed again must be replaced with new components.