[ Figure 2-1 : Derating Curve ]
Ambient temperature (°C)
20
0
0.5
1.5
2.5
3.5
1
2
3
4
4.5
5
30
40
50
60
70
Output Power (kW)
[ Table 2-3 : Maximum Charge Current Limit ]
(*) : Maximum Charge Current
- If the battery is discharged at the maximum discharge current / power, the battery should
be cooled its ambient temperature before discharging again.
Australia & New Zealand
Germany
09
I
Safety
Item
Cell body / module temperature
Cell body temperature
Max Cell V
Maximum
Charge Current(*)
0 A
3.5 A
7 A
9.8 A
3.5 A
2.1 A
Q.SAVE
G2
4kWh
Q.SAVE
G2
6.3kWh
T < 0 °C
0 °C ≤ T < 10 °C
10 °C ≤ T < 25 °C
25 °C ≤ T < 40 °C
40 °C ≤ T < 50 °C
50 °C ≤ T
T < -10 °C
-10 °C ≤ T < 0 °C
0 °C ≤ T < 10 °C
20 °C ≤ T < 45 °C
45 °C ≤ T < 55 °C
55 °C ≤ T
10 °C ≤ T < 20 °C
-
Max Cell V < 3.8
3.8 ≤ Max Cell V < 3.9
3.9 ≤ Max Cell V
Max Cell V < 3.8
3.8 ≤ Max Cell V < 4.0
4.0 ≤ Max Cell V
Max Cell V < 3.8
3.8 ≤ Max Cell V
-
-
-
0 A
7.5 A
3 A
0 A
7.5 A
3 A
0 A
15.6 A
10 A
15.6 A
10 A
3 A
Specification
Specification
Summary of Contents for Q.HOME+ ESS HYB-G2