G04P

INV OC P

INV RMS Over Current

Protection

The product stops the generating process

because a significant protection event has

occurred. Wait until the event message

disappears. After the event message is

removed, it automatically returns to normal.

If it is not removed until the time limit is

reached, it is converted to a significant event.

WEB Display

HMI Display

Description

Measures

G05P

INV OCP P

INV Over Current

Peak Protection

The product stops the generating process

because a significant protection event has

occurred. Wait until the event message

disappears. After the event message is

removed, it automatically returns to normal.

If it is not removed until the time limit is

reached, it is converted to a significant event.

G06P

INV OT P

INV Module Temp

Over Temp Protection

When the switch temperature is high.

Wait until the event message disappears.

After the event message is removed, it

automatically returns to normal. If it is not

removed until the time limit is reached,

it is converted to a significant event.

G07P

INV UT P

INV Module Temp

Under Temp Protection

When the switch temperature is low.

Wait until the event message disappears.

After the event message is removed, it

automatically returns to normal. If it is not

removed until the time limit is reached, it is

converted to a significant event.

G12P

GRID UV P

Grid RMS Under

Voltage Protection

Check the connection of Grid Voltage cable.

G13P

GRID OV P

Grid RMS Over

Voltage Protection

The product stops the generating process

because a significant protection event has

occurred. Wait until the event message

disappears. After the event message is

removed, it automatically returns to normal.

If it is not removed until the time limit is

reached, it is converted to a significant event.

G11P

GRID OW P

Grid Over Watt

Protection

The product stops the generating process

because a significant protection event has

occurred. Wait until the event message

disappears. After the event message is

removed, it automatically returns to normal.

If it is not removed until the time limit is

reached, it is converted to a significant event.

41 

I

 

Message Description

Summary of Contents for Q.HOME+ESS HYB-G2

Page 1: ...Connecting other products in parallel to Q HOME ESS HYB G2 may result in abnormal operation The internet connection is required to use all functions of the ESS system If you have a problem please contact the installer The Specifications of the product may be modified without prior notice to improve product quality NOTICE ...

Page 2: ......

Page 3: ...ndby Mode 4 2 PV Auto Mode 4 2 1 Weak 4 2 2 Strong 4 2 3 Both 4 3 PV Only Mode 4 4 Battery Discharge Mode 4 5 Stand Alone Mode 4 6 Event Check Mode 5 Communication 5 1 Overview 5 2 The Communication Terminal 5 3 Energy Meter Connection 5 3 1 RS 485 Interface 5 4 Recommended Energy Meter List 5 5 Homepage 5 5 1 Service Terms 5 5 2 Membership 5 5 3 Membership Withdrawal 5 5 4 Log In 5 5 5 Password I...

Page 4: ...ding Screen Update Screen 7 3 Home Screen Configuration Information 7 4 Home Menu Structure 7 5 Status Description 7 6 Information Display 7 6 1 PV Information Display 7 6 2 Grid Information Display 7 6 3 Load Information Display 7 6 4 Battery Information Display 7 6 5 System Information Display 7 6 6 Error Information Display 7 7 General Events 7 7 1 INVERTER General Events Protection 7 7 2 Batte...

Page 5: ...nformation Table 7 3 Status Description Table 7 4 PV Information Display Description Table 7 5 Grid Information Display Description Table 7 6 Load Information Display Description Table 7 7 Battery Information Display Description Table 7 8 System Information Display Description Table 7 9 Error Information Display Description Table 7 10 INVERTER General Events Warning List Table 7 11 Battery Operati...

Page 6: ...3 Log in Page Figure 5 4 Password Initialization Page Figure 5 5 Monitoring Page Figure 5 6 Backup Mode Monitoring Page Figure 5 7 Consumption Report Page Figure 5 8 Forecast Page Figure 5 9 Setting Page Figure 5 10 Mobile Service Page Figure 6 1 PV Connector MC4 Type Figure 7 1 LCD Location Figure 7 2 Initial Indication Screen on Power On Figure 7 3 Update Screen Figure 7 4 Standby State Indicati...

Page 7: ...This page is intentionally left blank ...

Page 8: ...t download section at https www q cells de service support downloadbereich html The specifications of the product can be changed for improvement without notice Also the software can be updated automatically without notice over the Internet 1 4 Symbols Used This symbol indicates a hazardous situation which could result in a light injury if not avoided CAUTION Description Symbols NOTICE INFORMATION ...

Page 9: ...Protective conductor terminal Direct current Earth terminal Three phase alternating current with neutral conductor Three phase alternating current Both direct and alternating current Alternating current Caution Hot Surface Beware of hot surface The INVERTER can become hot during operation Avoid contact during operation Follow the guidelines in all relevant documents enclosed along with the INVERTE...

Page 10: ...ance Description Symbols Electric shock hazard Do not remove cover or disassemble Explosive gas Do not expose to flame incinerate puncture or impact Shield eyes Wear safety goggles at ALL times Installation maintenance etc Do not dispose in trash Transport legally Follow manufacturer s instructions for disposal Please recycle Lithium ion Battery Do not discard Qualified technicians use this manual...

Page 11: ...lectric system This device should not be used for any purpose other than the purpose described in this installation manual Any substitute use of this device random change in any of its parts and use of components other than sold or recommended by Hansol Technics will nullify the product s guarantee For example Hansol Li Ion Battery energy storage should not be replaced by other manufacturer s Batt...

Page 12: ...1 First version Q HOME ESS HYB G2 HSHP 4601 HSHP Hansol Hybrid PCS 460 Power of INVERTER x0 01kwh If Power of INVERTER is more than 10kwh third number is K 1 First version INVERTER Power Conditioning System HSBE 4001 HSBE Hansol Battery 400 Battery capacity x0 01kwh 1 First version BATTERY Identifying the Product Attached on the enclosure of this product is the Type Label where the identity of thi...

Page 13: ...Safety I 06 The Type Label is shown in the Figure 2 2 and Figure 2 3 Figure 2 2 INVERTER Name Plate Figure 2 3 Battery Name Plate INVERTER Battery ...

Page 14: ...modules shall have an IEC61730 Application Class A rating or equivalent To connect Q HOME ESS HYB G2 with the Public Grid make sure to install the watt hour meter recommended by Hansol Technics refer to the installation manual and to install the distribution box between Q HOME ESS HYB G2 And the Grid watt hour meter Before installing the distribution box select a suitable location complying with t...

Page 15: ...wn in the distribution board connection diagram Make sure that the string numbers match correctly For example do not connect a PV string 1 to a PV string 2 Figure 2 5 Distribution Box Connection Diagram PVdso2 PVdso2 PVdso1 PVdso1 PVdso2 PVdso2 PVdso1 PVdso1 LGO NGO LG NG GRID LGO NGO LG NG House LOAD Distribution Board ...

Page 16: ...ut output short circuit current Battery technology DC DC converter technology Over voltage Category 1 Battery pack 2 or more Battery pack 4 0 kWh 3 6 kWh 9 8 A 2 kWh 4 0 kWh x Pack 3 6 kWh x Pack 17 A 3 kWh 30 A 176 4 Vdc 225 12 Vdc 203 84 Vdc 17 A 3 kWh 227 A 278 A 1 003 ms 1 222 ms Li Ion Non Isolated II PV Data DC Grid Data AC Rated power at 230V 50 Hz Max apparent AC power Nominal voltage rang...

Page 17: ... Touch TFT LCD 4 95 inch LAN Modbus TCP IP RS485 CAN Integrated IEC 62109 1 2 VDE AR N 4105 VDE 0126 1 1 EN 61000 6 2 and EN 61000 6 3 INVERTER IEC 62619 IEC 62477 1 EN 61000 6 2 and EN 61000 6 3 Battery Dimensions W x H x D mm Weight Protective class I II III Degree of protection Max permissible value for relative humidity Operating temperature Storage temperature INVERTER topology Noise emission...

Page 18: ... system should be installed out of the reach of children Even when no external voltage is applied to the system it may have internal high voltage in the device which can cause lethal damage to the human body High voltage can cause lethal damage to the human body CAUTION Photovoltaic array supplies DC voltage to the Q HOME ESS HYB G2 Do not touch the PV cable when it PV cable is connected to the PV...

Page 19: ...fer to the table of event messages for different significant general events CAUTION When transporting the Q HOME ESS HYB G2 work with at least two persons Overweight CAUTION Li Ion Battery energy storage system ESS inside When assembling the system do not intentionally short the positive and negative terminals with metallic object All work on the ESS and electrical connections must be carried out ...

Page 20: ...operation mode of this product is automatically determined by the EMS algorithm 3 1 INVERTER Product Overview Table 3 1 Part Description of INVERTER Figure 3 1 Part View of INVERTER INSIDE Description LCD Panel LED Indications Cable Gland for Battery Battery Communication PCS Communication Bracket Connected Part PV Input Connector MC4 type 2set AC Connector and Load Connector DC Disconnection Swit...

Page 21: ...duct Overview Battery Made by Samsung SDI Terminal and Circuit Breaker No Table 3 2 Part Description of Battery Pack Description BMS Board Cable Gland Bracket Connected Part BMS Communication Connector Figure 3 2 Part View of Battery Pack ...

Page 22: ... the EMS decision 4 2 PV Auto Mode This mode is divided into three types depending on the state of the Battery power 4 2 1 Weak Solar energy generation and Battery discharging are available The solar generated power is charged or discharged to the Battery based on the EMS decision A maximum of 4 6kW or more can be sent to Grid When Load Output Power Sub is higher than power generation of PV and Ba...

Page 23: ...ad Output Power Sub PV Input Power Energy Meter for Utility Battery Power One Way Bi directional way Inactive Grid Output Power Load Output Power Main Load Output Power Sub PV Input Power Energy Meter for Utility Battery Power One Way Bi directional way Inactive 4 2 3 Both Solar energy generation and Battery charging are available The solar generated power is charged or discharged to the Battery b...

Page 24: ...f no solar energy generation Battery discharge is only available on this mode Based on the EMS decision the Battery discharge power can be sent maximum 3kW or less only to the Load Figure 4 5 Diagram of Battery Discharge Mode Grid Output Power Load Output Power Main Load Output Power Sub PV Input Power Energy Meter for Utility Battery Power One Way Bi directional way Inactive Grid Output Power Loa...

Page 25: ...he Q HOME ESS HYB G2 enters into the Stand Alone Mode The system operates in a PV only mode Figure 4 6 Diagram of Stand Alone mode 4 6 Event Check Mode This mode stops solar energy generation and put it in standby mode as an event occurs Grid Output Power Load Output Power Main Load Output Power Sub PV Input Power Energy Meter for Utility Battery Power One Way Bi directional way Inactive ...

Page 26: ...onnection is properly completed you can monitor the system operation status on the computer 5 2 The Communication Terminal Communication terminal Energy meter Connect to RS 485 Energy Meter Out Connector Board CN2 CN906 CN2 CN1 CN3 CN4 CN5 CN905 CN901 CN902 CN904 Energy Meter RS485 CAN I O EXT Emergency ...

Page 27: ... RS 485 Meter The Energy Meter uses RS 485 Interface for communication Connection line Not provided in the product package It should be applied to a twisted pair type Cable length limit The RS 485 meter communication cable must be used within 100 m 5 4 Recommended Energy Meter List 5 3 1 2 Connection terminal Make sure that the housing and connector are connected As shown in the Figure 5 2 separat...

Page 28: ...omepage During membership registration the member s information such as ID password name and the address are collected and additional data may also be collected to provide statistical information upon customer s approval 5 5 3 Membership Withdrawal For a customer who does not want to use this service membership withdrawal is available through the personal information modification menu on the homep...

Page 29: ...ess 5 5 6 Types of Service Offered After completing log in normal service is available This service currently provides such menu items as monitoring consumption reports ESS reports ESS forecasts and notices 5 5 6 1 Monitoring The operational status of the product is indicated You can check the current status of operation the customer s power consumption information and power generation amount info...

Page 30: ...ormation on as the household type the size and the number of family residents is collected according to the customer s approval You can use these data to identify various types of statistics and comparative analysis data 5 5 6 4 ESS Forecast In the ESS Forecast menu the generation amount forecast information and the guide for optimized operation can be checked through the algorithm mounted on the ...

Page 31: ...are version of the product on the monitoring page 5 5 7 Mobile Service Customers who use Android or I Phone can use a smart phone to easily check the product status anytime anywhere To use the mobile service the customer must first register the membership through the webpage and use the ID and the password to log in Figure 5 9 Setting Page Figure 5 10 Mobile Service Page Figure 5 8 Forecast Page ...

Page 32: ...e circuit breaker to cut off the Battery DC 3 Disassembling the system 6 2 1 Fuse Check Check the fuse when the device fails to work with significant error Do not perform Fuse Check when the device is working Check the fuse after turning off the DC disconnect switch and the AC circuit breaker Measure both ends of the Filter PBA F101 F102 and F401 check the resistance value If the resistance value ...

Page 33: ...es Disconnect charging source prior to connecting or disconnecting Battery terminals Determine if the Battery is inadvertently grounded If that is the case separate Battery from ground Contact with any part of a grounded Battery can result in electrical shock The likelihood of such shock can be reduced if such grounds are removed during installation and maintenance applicable to equipment and remo...

Page 34: ...re exchange the Battery However Battery exchange is permitted only to the qualified personnel 6 3 2 Battery Exchange Procedure 1 Disconnect the BMS communication cable 2 Open the bottom cover of the Battery you want to replace 3 Remove the ground and wire 4 Close the Battery bottom cover and move the Battery pack to a suitable location 5 Prepare the Battery pack to be installed and proceed as desc...

Page 35: ...rn on the DC disconnect switch on the product Check the system check message on the front LCD screen 7 2 1 Loading Screen Update Screen The Figure 7 2 is displayed at the time of initial boot and the home screen is displayed when internal communication is normal The time setting is automatically renewed when connected to the network The Figure 7 3 is a screen display when ESS Software PMS PCS is u...

Page 36: ...nication connection status PV Battery Indication during independent operation Display status when connecting to Ethernet network Display status when connecting to meter Go to home display Go to previous screen Go to next screen Display current PV power Display current Load power Display current Battery power Display current Grid power Display ESS normal operation Standby Normal Fault Fault Lock Er...

Page 37: ... 4 Home Menu Structure 7 4 Home Menu Structure If you touch next or previous button the screen is displayed as shown in the Figure 7 4 The description of each screen refer to Chapter 7 6 Message Description I 30 ...

Page 38: ... is generated by PV Description ESS ESS Battery Charge The Battery is charging Battery Discharge The Battery is discharging Grid Input Supply the electrical power of Grid to INVERTER Grid Output The power generated from the PV is fed into the Grid Load Input The power generated by INVERTER is supplied to Load ESS ESS ESS ESS ...

Page 39: ... PV2 Voltage PV2 Current PV2 Power Today Power Total Power Graph Display current PV1 voltage Display current PV1 current Display current PV1 power Display current PV2 voltage Display current PV2 current Display current PV2 power Display today s PV power Display the mount of PV power Display PV power graph Daily Weekly Monthly Yearly If you want to see the next graph touch graph screen Description ...

Page 40: ... in Power Total Feed out Power Graph Display Grid voltage Display Grid frequency Display Grid current Display Grid active power Display Grid power factor Display today s power received from the Grid Display today s electricity sent to the Grid Display the amount of electricity received from the Grid Display the amount of electricity sent to the Grid Display Grid power graph Daily Weekly Monthly Ye...

Page 41: ...Description Voltage Current Frequency Power Today Power Total in Power Graph Display Load voltage Display Load current Display Load frequency Display Load active power Display today s Load power Display the amount of power used in today s Load Display Load power graph Daily Weekly Monthly Yearly If you want to see the next graph touch graph screen ...

Page 42: ...Discharge Power Total Power Charge Total Power Discharge Graph Display Battery voltage Display Battery current Display Battery charging discharging power Display today s Battery charge power Display Battery power factor Display the amount of Battery charge power Display the amount of Battery discharge power Display Battery power graph Daily Weekly Monthly Yearly If you want to see the next graph t...

Page 43: ...scription Product Model Product Country Software Version PMS Version PCS Master Version PCS Slave Version HMI Version BMS Version Name of this product Country using this product Software version of this product Software version of PMS Software version of PCS master Software version of PCS slave Software version of HMI Software version of BMS up to 5 types ...

Page 44: ...ation Display Figure 7 10 Error Information Display Table 7 9 Error Information Display Description Date Time Error The date the fault occurred The time the fault occurred ed Type of fault See Chapter 7 6 If there are more than 10 errors the first error is cleared ...

Page 45: ...ssage is removed it automatically returns to normal If it is not removed until the time limit is reached it is converted to a significant event D03P BDC1 COC P BDC1 Charge RMS Over Current Protection The product stops the generating process because a significant protection event has occurred Wait until the event message disappears After the event message is removed it automatically returns to norm...

Page 46: ...ion The product stops the generating process because a significant protection event has occurred Wait until the event message disappears After the event message is removed it automatically returns to normal If it is not removed until the time limit is reached it is converted to a significant event D21P BDC UV P BDC RMS Under Voltage Protection The product stops the generating process because a sig...

Page 47: ...perature is low Wait until the event message disappears After the event message is removed it automatically returns to normal If it is not removed until the time limit is reached it is converted to a significant event G02P INV I TZS P INV Current Trip Zone Slave Protection The product stops the generating process because a significant protection event has occurred Wait until the event message disa...

Page 48: ...il the time limit is reached it is converted to a significant event G07P INV UT P INV Module Temp Under Temp Protection When the switch temperature is low Wait until the event message disappears After the event message is removed it automatically returns to normal If it is not removed until the time limit is reached it is converted to a significant event G12P GRID UV P Grid RMS Under Voltage Prote...

Page 49: ...t has occurred Wait until the event message disappears After the event message is removed it automatically returns to normal If it is not removed until the time limit is reached it is converted to a significant event G23P RCMU SD P Residual Current Monitoring Unit Sudden Protection Turn off system power when the leakage current level is above standard level Check the leakage current level then res...

Page 50: ...d it automatically returns to normal If it is not removed until the time limit is reached it is converted to a significant event L04P Load OV P Load RMS Over Voltage Protection The product stops the generating process because a significant protection event has occurred Wait until the event message disappears After the event message is removed it automatically returns to normal If it is not removed...

Page 51: ...duct stops the generating process because a significant protection event has occurred Wait until the event message disappears After the event message is removed it automatically returns to normal If it is not removed until the time limit is reached it is converted to a significant event S04P PV1 OV P PV1 RMS Over Voltage Protection The product stops the generating process because a significant pro...

Page 52: ...generating process because a significant protection event has occurred Wait until the event message disappears After the event message is removed it automatically returns to normal If it is not removed until the time limit is reached it is converted to a significant event S14P PV2 OV P PV2 RMS Over Voltage Protection The product stops the generating process because a significant protection event h...

Page 53: ...nder Temp Protection When the switch temperature is low Wait until the event message disappears After the event message is removed it automatically returns to normal If it is not removed until the time limit is reached it is converted to a significant event S23P PV1 INSULATION P PV1 Insulation Protection Turn off system power if PV1 insulation resistance is at the standard level S31P DCLINK V TZM ...

Page 54: ...s removed it automatically returns to normal If it is not removed until the time limit is reached it is converted to a significant event S33P DCLINK OV P DCLINK RMS Over Voltage Protection The product stops the generating process because a significant protection event has occurred Wait until the event message disappears After the event message is removed it automatically returns to normal If it is...

Page 55: ...ted to a significant event B03P BAT1 CEL V HOLD P BAT1 Cell Voltage Sensing Data Hold Protection Power reset of the system is required If the symptom still occurs after reset repair of BMS or PCS Control Board is necessary B04P BAT1 CEL OV P BAT1 Cell or Rack Over Voltage Protection When the maximum cell or rack voltage is above protection level thus terminating the system Automatically returns to...

Page 56: ...event message is removed it automatically returns to normal If it is not removed until the time limit is reached it is converted to a significant event B14P BAT2 CEL OV P BAT2 Cell or Rack Over Voltage Protection When the maximum cell or rack voltage is above protection level thus terminating the system Automatically returns to normal when the maximum cell or rack voltage goes below the limit valu...

Page 57: ... removed until the time limit is reached it is converted to a significant event B23P BAT3 CEL V HOLD P BAT3 Cell Voltage Sensing Data Hold Protection Power reset of the system is required If the symptom still occurs after reset repair of BMS or PCS Control Board is necessary B22P BAT3 DCHG OC P BAT3 Discharge Over Current Protection The product stops the generating process because a significant pr...

Page 58: ...s not removed until the time limit is reached it is converted to a significant event B34P BAT4 CEL OV P BAT4 Cell or Rack Over Voltage Protection When the maximum cell or rack voltage is above protection level thus terminating the system Automatically returns to normal when the maximum cell or rack voltage goes below the limit value B35P BAT4 CEL UV P BAT4 Cell or Rack Under Voltage Protection Whe...

Page 59: ...s not removed until the time limit is reached it is converted to a significant event B43P BAT5 CEL V HOLD P BAT5 Cell Voltage Sensing Data Hold Protection Power reset of the system is required If the symptom still occurs after reset repair of BMS or PCS Control Board is necessary B42P BAT5 DCHG OC P BAT5 Discharge Over Current Protection The product stops the generating process because a significa...

Page 60: ... BAT5 COM P BAT5 Communication Protection Power reset of the system is required If the symptom persists after reset replace the cable connecting the Battery pack and the INVERTER After replacement repair of BMS or PCS Control Board is necessary B48P BAT5 ADD P BAT5 Additional Protection Power reset of the system is required If the symptom still occurs after reset repair of BMS or PCS Control Board...

Page 61: ...re again P21P DSPM FRAM P DSP Master FRAM Communication Error Protection Please turn off and restart the system If an error occurs repeatedly it is necessary to replace the Control Board P22P DSPS FRAM P DSP Slave FRAM Communication Error Protection Please turn off and restart the system If an error occurs repeatedly it is necessary to replace the Control Board P23P DSP COM P DSPM DSPS Communicati...

Page 62: ...ery Photo Voltaic A box containing AC DC ON OFF switches for electricity distribution Alternating Current Direct Current Liquid Crystal Display An electric circuit that converts DC to AC and vice versa An electric circuit that converts DC to DC Describes series connected photovoltaic modules Power Load Chapter 1 Chapter 2 Chapter 7 CELL Battery Individual Cell 55 I Arrangement of Terms ...

Page 63: ...nsol com For technical problems or inquiries for use please contact the installation company To receive customer support the following information is required 1 Product type HSHP 4601 2 Serial Number HSHP4601Z1XXXXXXXX 3 PV module type and configuration 4 Option equipment Energy Meter Model Name Contact I 56 ...