INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.MAXX-G2 – Q CELLS
INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.MAXX-G2 – Q CELLS
Validity
These instructions are only valid for crystalline solar modules from
the company Q CELLS as specified at chapter „2.1 Technical
Specifications“. Q CELLS assumes no liability for damage resulting
from failure to observe these instructions.
Ä
Please observe the wiring and dimensioning of the system.
Ä
The installer of the system is responsible for compliance with all
necessary safety regulations during set-up and installation.
Q CELLS assumes no liability on the basis of these instructions.
Q CELLS is only liable in the context of contractual agreements
or in the context of accepted guarantees. Q CELLS accepts no
other responsibility for the functionality and safety of the modules.
Ä
Please observe the instructions for any other system compo-
nents that may be part of the complete solar power system.
It may be necessary to carry out a structural analysis for the
entire project.
Additional information for the Operator
Ä
Please keep this manual for the entire life of the solar power
system.
Ä
Please contact your system supplier for information concerning
the formal requirements for solar power systems.
Ä
Please be sure to contact the relevant local authorities and
energy providers regarding regulations and permit requirements
prior to installation of the solar power system.
Other applicable documents
In addition to this Manual following technical information are
relevant:
DOCUMENT TYPE
Product data sheet
Packaging and transport information
For additional information see the relevant datasheet of the module provided at www.q-cells.com.
PRODUCT LINE
Q.MAXX-G2
Type
Q.ANTUM DUO
Length
1740 mm
Width
1030 mm
Frame height
32 mm
Area
1.79 m²
Weight
19.9 kg
Max. system voltage V
SYS
1000 V
Max. reverse current
20 A
Permissible
temperature range
–40 °C to +85 °C (–40 °F to +185 °F)
Junction box
protection class
IP67 with bypass diode
Connector protection class
IP68
Fire rating based on ANSI / UL 61730
C / Type 2
Max. test load Push/Pull
1
5,400 Pa / 2,400 Pa
Max. design load Push/Pull
1
3,600 Pa / 1,600 Pa
Certificates
VDE Quality Tested; CE-compliant; IEC 61215:2016; IEC 61730:2016;
PV module classification: Class II
1
Test and design load in accordance with IEC 61215:2016, depending on mounting options (see section „2.3 Mounting Options“)
1 INTRODUCTION
2 PLANNING
2.1 TECHNICAL SPECIFICATIONS
Fig. 1:
External dimensions and components for
Q.MAXX-G2
DETAIL A
16 mm
8.5 mm
24.5 mm
980 mm
1740 mm
4 × Mounting slots (DETAIL A)
Frame
1030 mm
981 mm
32 mm
8 × Drainage holes
380 mm
EN
4 × Grounding points ø 4.5 mm
Label
≥
1150 mm
≥
1150 mm