Valid for North America
Q.PRO-G4 · Q.PRO BFR-G4.1 · Q.PRO BLK-G4 · Q.PLUS BFR-G4.1
INSTALLATION AND
OPERATION MANUAL
Page 1: ...Valid for North America Q PRO G4 Q PRO BFR G4 1 Q PRO BLK G4 Q PLUS BFR G4 1 INSTALLATION AND OPERATION MANUAL...
Page 2: ...check the results of said procedure Prohibited Beware of possible danger or damage Categories Danger Risk of fatal injury Attention Risk of serious injury or damage to property Note Risk of damage to...
Page 3: ...rantees Q CELLS accepts no other responsibility for the functionality and safety of the modules Please observe the instructions for any other system components that may be part of the complete solar p...
Page 4: ...he mounting frame are compatible Clamp System Requirements Use customary clamps that satisfy the following requirements Clamp width 1 57in 40 mm Clamp height compliant with a 1 26in 32 mm frame height...
Page 5: ...structure support Push 0 3 94 0 100 1200 2400 2400 Pull 0 3 94 0 100 1100 1 Distance between outer edge of module and middle of the clamp Describes the maximum module surface load vertical to the modu...
Page 6: ...nal multiplying factor of 125 percent 80 percent derating which might be applicable Please follow the valid national guidelines for the installation of electrical systems refer to section 690 8 of the...
Page 7: ...own NOTE Module damage may occur Never step on modules Do not subject modules to any mechanical stress Do not allow any objects to fall onto modules 3 1 Safety and transport 3 INSTALLATION DANGER Risk...
Page 8: ...m the separation of a closed circuit These can result in life threatening injuries The danger increases when several modules are connected in series Please be aware of that the entire open circuit vol...
Page 9: ...and qualified tools of the manufacturer Tyco Amphenol or Multicontact 2 Cover the modules to be disconnected 4 2 Electrical installation safety 4 ELECTRICAL CONNECTION Use solar cables for the connec...
Page 10: ...factors Option A Use of a grounding lug A listed grounding lug can be bonded to the frame using the grounding holes pre drilled in the frame These holes are marked Dimensions shown are in inches 0 1 7...
Page 11: ...ry due to hot and live modules Only clean modules that have cooled down Do not carry or wear any electrically conductive parts WARNING Risk of falling due to unsecured access Never access the installa...
Page 12: ...CA INC 300 Spectrum Center Drive Suite 1250 Irvine CA 92618 USA TEL 1 848 748 59 96 EMAIL inquiry us q cells com WEB www q cells us Subject to change without notice Hanwha Q CELLS Installation manual...