INSTaLLaTIoN aND oPeraTIoN MaNUaL SoLar MoDULeS GeNeraTIoN 3 (G3) – HaNWHa Q CeLLS aUSTraLIa PTY LTD

INSTaLLaTIoN aND oPeraTIoN MaNUaL SoLar MoDULeS GeNeraTIoN 3 (G3) – HaNWHa Q CeLLS aUSTraLIa PTY LTD

Additional information can be found in the currently valid data sheets available at www.q-cells.com.

ProDUCT LINe

Q.PLUS-G3

Q.Pro-G3

Q.Pro BLK-G3

Type

Q.ANtum

Polycrystalline

Polycrystalline

Area [m²]

1.67

1.67

1.67

Frame height [mm]

35

35

35

Weight [kg]

19.0

19.0

19.0

Max. system voltage V

SYS

 [V]

1000

1000

1000

Max. reverse current [A]

20

20

20

Permissible temperature range

–40 °c to +85 °c (–40 °F bis +185 °F)

Junction box protection class

iP67 with bypass diode

Connector protection class

iP68

iP68

iP68

Fire protection class

c

c

c

Snow load [Pa]

1

5400

5400

5400

Wind load [Pa]

1

5400

5400

5400

Certificates

VDe Quality tested; ce-compliant; iec 61215 (ed.2) see page 9 et sqq.; iec 
61730 (ed.1) Application class A

Validity

these instructions are only valid for crystalline solar 
modules from the company Q ceLLs. Q ceLLs assumes 
no liability for damage resulting from failure to observe 
these instructions. 

 

Ä

Please observe the wiring and dimensioning of the 
system.

 

Ä

the installer of the system is responsible for compliance 
with all necessary safety regulations during set-up and 
installation.

Q ceLLs assumes no liability on the basis of these 
instructions. Q ceLLs is only liable in the context of 
contractual agreements or in the context of accepted 
guarantees. Q ceLLs accepts no other responsibility for 
the functionality and safety of the modules. 

 

Ä

Please observe the instructions for any other sys-
tem components that may be part of the complete  
solar power system. it may be necessary to carry out a 
structural analysis for the entire project. 

 

Ä

if your questions are not satisfactorily answered 

 

in the manual, please contact your system supplier. 

Additional information can be found on our website at 
www.q-cells.com.au.

if you have any questions, please contact our customer 
service Department at q-cells-australia@q-cells.com.

Information for the operator

 

Ä

Please keep this manual for the entire life of the solar 
power system.

 

Ä

Please contact your system supplier for information 
concerning the formal requirements for solar power 
systems.

 

Ä

Please be sure to contact the relevant local authorities 
and energy providers regarding regulations and permit 
requirements prior to installation of the solar power 
system.

other applicable documents

this installation manual is only valid in combination with 
the following technical information.

DoCUMeNT TYPe

Product data sheet

Packaging and transport of crystalline modules

1 INTroDUCTIoN

2.1  Technical specifications

2 PLaNNING

ProDUCT LINe

Q.PeaK-G3

Type

monocrystalline

Area [m²]

1.67

Frame height [mm]

35

Weight [kg]

19.0

Max. system voltage V

SYS

 [V]

1000

Max. reverse current [A]

20

Permissible temperature range

–40 °c to +85 °c (–40 °F to +185 °F)

Junction box protection class

iP67 with bypass diode

Connector protection class

iP68

Fire protection class

c

Snow load [Pa]

1

5400

Wind load [Pa]

1

5400

Certificates

VDe Quality tested; ce-compliant; iec 
61215 (ed.2) see page 9 et sqq.; iec 
61730 (ed.1) Application class A

1

   tested according to iec 61215

Summary of Contents for Q.Pro-G3

Page 1: ...Valid for Australia and New Zealand Q Pro G3 Q PRO BLK G3 Q Peak G3 Q PLUS G3 Installation and Operation Manual...

Page 2: ...hibited Beware of possible danger or damage Categories Danger Risk of fatal injury Attention Risk of serious injury or damage to property Note Risk of damage to product Safety Regulations The solar mo...

Page 3: ...ility for the functionality and safety of the modules Please observe the instructions for any other sys tem components that may be part of the complete solar power system It may be necessary to carry...

Page 4: ...to the ground the roof or the fa ade Forces acting on the module are relayed to the mounting substructure Ensures sufficient rear ventilation of the module Guarantees long term stability Has electroc...

Page 5: ...unting options Specifications Module type Mounting option Clamping range1 Mm Allowed static load2 PA TEST LOAD acc IEC 61215 PA Q PRO G3 Q PRO BLK G3 Q PEAK G3 Q PLUS G3 CL1 Push 245 345 346 445 3500...

Page 6: ...ts ground leaks or defective insulation Ensure that the maximum reverse current load capacity indicated in the data sheet is observed In order to limit reverse currents that may occur we recommend usi...

Page 7: ...ginal packaging until installation Store the modules securely in cool and dry rooms The packaging is not weatherproof Danger Risk of fatal injury due to electric shock Do not install damaged modules I...

Page 8: ...l modules in windy or wet weather Danger Risk of fatal injury due to electric shock Only use dry insulated tools Do not carry out the installation alone Only install undamaged modules and components D...

Page 9: ...rter and the wiring with extreme caution Ensure that the modules are disconnected at the inverter prior to separation Be sure to observe the specified time intervals after switching off the inverter H...

Page 10: ...shock Ensure that all electrical components are in a proper dry and safe condition A module with 1 160 mm long cable can be wired as a 2nd next neighbor 2nd next neighbor Wiring without a return cabl...

Page 11: ...of performance Maintenance The system should be inspected by an installer annually to check the following all system components sit securely and are corrosion free the connection is secure and all ele...

Page 12: ...20 Berry Street North Sydney NSW 2060 Australia TEL 61 0 29016 3033 FAX 61 0 269016 3032 EMAIL q cells australia q cells com WEB www q cells com au Subject to change without notice Hanwha Q CELLS Gmb...

Reviews: