4
5
INSTaLLaTIoN aND oPeraTIoN MaNUaL SoLar MoDULeS GeNeraTIoN 3 (G3) – HaNWHa Q CeLLS aUSTraLIa PTY LTD
INSTaLLaTIoN aND oPeraTIoN MaNUaL SoLar MoDULeS GeNeraTIoN 3 (G3) – HaNWHa Q CeLLS aUSTraLIa PTY LTD
Additional information can be found in the currently valid data sheets available at www.q-cells.com.
ProDUCT LINe
Q.PLUS-G3
Q.Pro-G3
Q.Pro BLK-G3
Type
Q.ANtum
Polycrystalline
Polycrystalline
Area [m²]
1.67
1.67
1.67
Frame height [mm]
35
35
35
Weight [kg]
19.0
19.0
19.0
Max. system voltage V
SYS
[V]
1000
1000
1000
Max. reverse current [A]
20
20
20
Permissible temperature range
–40 °c to +85 °c (–40 °F bis +185 °F)
Junction box protection class
iP67 with bypass diode
Connector protection class
iP68
iP68
iP68
Fire protection class
c
c
c
Snow load [Pa]
1
5400
5400
5400
Wind load [Pa]
1
5400
5400
5400
Certificates
VDe Quality tested; ce-compliant; iec 61215 (ed.2) see page 9 et sqq.; iec
61730 (ed.1) Application class A
Validity
these instructions are only valid for crystalline solar
modules from the company Q ceLLs. Q ceLLs assumes
no liability for damage resulting from failure to observe
these instructions.
Ä
Please observe the wiring and dimensioning of the
system.
Ä
the installer of the system is responsible for compliance
with all necessary safety regulations during set-up and
installation.
Q ceLLs assumes no liability on the basis of these
instructions. Q ceLLs is only liable in the context of
contractual agreements or in the context of accepted
guarantees. Q ceLLs accepts no other responsibility for
the functionality and safety of the modules.
Ä
Please observe the instructions for any other sys-
tem components that may be part of the complete
solar power system. it may be necessary to carry out a
structural analysis for the entire project.
Ä
if your questions are not satisfactorily answered
in the manual, please contact your system supplier.
Additional information can be found on our website at
www.q-cells.com.au.
if you have any questions, please contact our customer
service Department at q-cells-australia@q-cells.com.
Information for the operator
Ä
Please keep this manual for the entire life of the solar
power system.
Ä
Please contact your system supplier for information
concerning the formal requirements for solar power
systems.
Ä
Please be sure to contact the relevant local authorities
and energy providers regarding regulations and permit
requirements prior to installation of the solar power
system.
other applicable documents
this installation manual is only valid in combination with
the following technical information.
DoCUMeNT TYPe
Product data sheet
Packaging and transport of crystalline modules
1 INTroDUCTIoN
2.1 Technical specifications
2 PLaNNING
ProDUCT LINe
Q.PeaK-G3
Type
monocrystalline
Area [m²]
1.67
Frame height [mm]
35
Weight [kg]
19.0
Max. system voltage V
SYS
[V]
1000
Max. reverse current [A]
20
Permissible temperature range
–40 °c to +85 °c (–40 °F to +185 °F)
Junction box protection class
iP67 with bypass diode
Connector protection class
iP68
Fire protection class
c
Snow load [Pa]
1
5400
Wind load [Pa]
1
5400
Certificates
VDe Quality tested; ce-compliant; iec
61215 (ed.2) see page 9 et sqq.; iec
61730 (ed.1) Application class A
1
tested according to iec 61215