Fig. 2: 

installation options for crystalline Q ceLLs modules. All dimensions are given in mm. Also observe the  

 

 

allowed static loads and clamping range as specified on the following page.

 

 

the illustrated installation options apply for both horizontal and vertical module orientation. 

 

Module 

Clamp 

Subconstruction 

Mounting profile

2.3  Mounting options

2 PLaNNING

TYPe of 
INSTaLLaTIoN

MoDULe

PoINT MoUNTING SYSTeM

LINear MoUNTING SYSTeM

INSTaLLaTIoN WITH  
CLaMPS

Q.PRo-G3 
Q.PRo BLK-G3
Q.PeAK-G3
Q.PLus-G3

INSTaLLaTIoN  
oN  
MoUNTING  
PoINTS

Q.PRo-G3
Q.PRo BLK-G3
Q.PeAK-G3
Q.PLus-G3

INSTaLLaTIoN WITH  
INSerTIoN ProfILeS

Q.PRo-G3
Q.PRo BLK-G3
Q.PeAK-G3
Q.PLus-G3

not permitted

IP1

IP2

CL3

CL4

245 - 445

180 - 380

0 - 300

0 - 300

CL1

245 - 445

180 - 380

2 PLaNNING

2.3  Mounting options

Specifications

 

MoDULe TYPe

MoUNTING oPTIoN

CLaMPING raNGe

1

 

[MM]

aLLoWeD STaTIC 
LoaD

[Pa]

TeST LoaD 
aCC. IeC 61215 [Pa]

Q.PRO-G3

Q.PRO BLK-G3 

Q.PEAK-G3

Q.PLUS-G3

CL1

Push

245 - 345
346 - 445

3500
2400

5400

Pull

245 - 345
346 - 445

5650
4000

CL3

Push

245 - 445

5700

Pull

245 - 345
346 - 445

4000
4000

CL4

Push

0 - 300

2000

Pull

0 - 300

2000

FB1

Push

3500

Pull

3100

FB2

Push

4000

Pull

3100

IP1

Push

-

3700

Pull

-

3700

IP2

Push

-

1800

2400

Pull

-

1800

1

 Distance between outer edge of module and middle of the clamp.

2

 Describes the maximum module surface load (vertical to the module surface) regarding safety factors (e.g. euRocoDe). 

For this purpose, the load value determined by load tests according to various criteria: laminate overlay, plastic 
deformation, module failure, and were divided with a safety factor. the minimum calculated load value corresponds 
to the maximum permitted load. 

345

280

FB2

4 x Fastening 
points

4 x Fastening 
points

345

4 x Fastening 
points

280

4 x Fastening 
points

FB1

CL1

245 - 445

180 - 380

CL3

CL4

245 - 445

180 - 380

0 - 300

0 - 300

345

4 x Fastening 
points

280

4 x Fastening 
points

FB1

345

280

FB2

4 x Fastening 
points

4 x Fastening 
points

IP1

IP2

Summary of Contents for Q.Pro-G3

Page 1: ...Valid for Australia and New Zealand Q Pro G3 Q PRO BLK G3 Q Peak G3 Q PLUS G3 Installation and Operation Manual...

Page 2: ...hibited Beware of possible danger or damage Categories Danger Risk of fatal injury Attention Risk of serious injury or damage to property Note Risk of damage to product Safety Regulations The solar mo...

Page 3: ...ility for the functionality and safety of the modules Please observe the instructions for any other sys tem components that may be part of the complete solar power system It may be necessary to carry...

Page 4: ...to the ground the roof or the fa ade Forces acting on the module are relayed to the mounting substructure Ensures sufficient rear ventilation of the module Guarantees long term stability Has electroc...

Page 5: ...unting options Specifications Module type Mounting option Clamping range1 Mm Allowed static load2 PA TEST LOAD acc IEC 61215 PA Q PRO G3 Q PRO BLK G3 Q PEAK G3 Q PLUS G3 CL1 Push 245 345 346 445 3500...

Page 6: ...ts ground leaks or defective insulation Ensure that the maximum reverse current load capacity indicated in the data sheet is observed In order to limit reverse currents that may occur we recommend usi...

Page 7: ...ginal packaging until installation Store the modules securely in cool and dry rooms The packaging is not weatherproof Danger Risk of fatal injury due to electric shock Do not install damaged modules I...

Page 8: ...l modules in windy or wet weather Danger Risk of fatal injury due to electric shock Only use dry insulated tools Do not carry out the installation alone Only install undamaged modules and components D...

Page 9: ...rter and the wiring with extreme caution Ensure that the modules are disconnected at the inverter prior to separation Be sure to observe the specified time intervals after switching off the inverter H...

Page 10: ...shock Ensure that all electrical components are in a proper dry and safe condition A module with 1 160 mm long cable can be wired as a 2nd next neighbor 2nd next neighbor Wiring without a return cabl...

Page 11: ...of performance Maintenance The system should be inspected by an installer annually to check the following all system components sit securely and are corrosion free the connection is secure and all ele...

Page 12: ...20 Berry Street North Sydney NSW 2060 Australia TEL 61 0 29016 3033 FAX 61 0 269016 3032 EMAIL q cells australia q cells com WEB www q cells com au Subject to change without notice Hanwha Q CELLS Gmb...

Reviews: