4
5
INSTALLATIoN AND oPErATIoN MANUAL SoLAr MoDULES GENErATIoN 4 (G4) – HANwHA Q CELLS GMBH – NA
INSTALLATIoN AND oPErATIoN MANUAL SoLAr MoDULES GENErATIoN 4 (G4) – HANwHA Q CELLS GMBH – NA
For the electrical data and additional information of the solar modules please refer to the respective currently valid data sheets available at
www.q-cells.com.
ProDUCT LINE
Q.Pro-G4 / Q.Pro BFr-G4 / Q.Pro BLKG4
Q.PLUS-G4
Cell type
Polycrystalline
Q.ANTUM
Length [
in
(mm)]
65.7 (1670)
65.7 (1670)
Width [
in
(mm)]
39.4 (1000)
39.4 (1000)
Height [
in
(mm)]
1.26 (32)
1.26 (32)
Area [yd² (m²)]
2 (1.67)
2 (1.67)
Weight [lb (kg)]
41.45 (18.8)
41.45 (18.8)
Max. system voltage V
SYS
[V]
1000
1000
Max. series fuse rating [A]
20
20
Permissible operating
temperature range [°F (°C)]
–40 to +185 (–40 to +85)
Junction box protection class
IP67 with bypass diode
Connector protection class
IP68
IP68
Fire protection class
C, Type 1
C, Type 1
Snow load [Pa]
1
5,400
5,400
Wind load [Pa]
1
4,000
4,000
Certificates
UL 1703; VDE Quality Tested; CE-compliant; IEC 61215 (Ed.2) see page 9 et sqq.; IEC 61730
(Ed.1) Application Class A
1
tested according to IEC 61215
Validity
These instructions are only valid for crystalline solar modules from
Q CELLS. Q CELLS assumes no liability for damage resulting from
failure to observe these instructions.
Ä
Please observe the wiring and dimensioning of the system.
Ä
The installer of the system is responsible for compliance with all
necessary safety regulations during set-up and installation.
Q CELLS assumes no liability on the basis of these instructions.
Q CELLS is only liable in the context of contractual agreements or
in the context of accepted guarantees. Q CELLS accepts no other
responsibility for the functionality and safety of the modules.
Ä
Please observe the instructions for any other system components
that may be part of the complete solar power system. It may be
necessary to carry out a structural analysis for the entire project.
Ä
If your questions are not satisfactorily answered in the manual,
please contact your system supplier.
Additional information can be found on our website at:
www.q-cells.com.
Information for the operator
Ä
Please keep this manual for the entire life of the solar power
system.
Ä
Please contact your system supplier for information concerning
the formal requirements for solar power systems.
Ä
Please be sure to contact the relevant local authorities and energy
providers regarding regulations and permit requirements prior
to installation of the solar power system. Your financial success
depends on the fulfillment of these requirements.
other applicable documents
This installation manual is only valid in combination with the
following technical information.
DoCUMENT TyPE
Product data sheet
Packaging and transport information
MISUSE OR INCORRECT USE OF SOLAR MODULES VOIDS THE
LIMITED WARRANTY AND MAY CREATE A SAFETY HAZARD
AND RISK PROPERTY DAMAGE. THIS INCLUDES IMPROPER
INSTALLATION OR CONFIGURATION, IM PROPER MAINTENANCE,
UNINTENDED USE, AND UNAUTHORIZED MODIFICATION.
1 INTroDUCTIoN
2.1 Technical specifications
2 PLANNING
Fig. 1:
External dimensions (in inch (mm)) and components for Q.PRO-G4, Q.PRO BFR-G4, Q.PRO BLK-G4, Q.PLUS-G4
NA
DETAIL A
0.630" (16 mm)
0.335" (8.5 mm)
0.965" (24.5 mm)
Junction bo×
Product label
35.58" (980 mm)
65.7" (1670 mm)
4 × Fastening points (DETAIL A)
Cable with
connectors
Frame
5.90" (150
mm)
39.4" (1000 mm)
37.44" (951 mm)
1.26" (32 mm)
8 × Drainage holes
6 × Grounding points ø 0.177" (4.5 mm)
39.37" (1000 mm)
Fig. 2:
External dimensions (in inch (mm)) and components for Q.PRO-G4 (with 46.06 in fastening point distance)
NA
DETAIL A 0.630" (16 mm)
0.334" (8.5 mm)
0.964" (24.5 mm)
Junction bo×
Product label
46.06" (1170 mm)
65.7" (1670 mm)
4 × Fastening points (DETAIL A)
Cable with
connectors
Frame
3.93"
(100 mm)
39.4" (1000 mm)
37.44" (951 mm)
1.38" (32 mm)
8 × Drainage holes
6 × Grounding points ø 0.177" (4.5 mm)
39.37" (1000 mm)