17
ERROR MESSAGE
ERROR TYPE
P01
The upper left IR sensor is failure.
P02
The upper right IR sensor is failure.
P03
The below left IR sensor is failure.
P04
The below right IR sensor is failure.
P05
The feeding sensor is failure.
P06
The size sensor is failure.
P09
The right passing sensor is failure.
P10
The left passing sensor is failure.
Detective Errors
If the following error code is displayed on the display window during the course of detecting,
you can handle them as per the error type after the machine is stopped.
ERROR MESSAGE
ERROR TYPE
E01
Length Error
E02/E03
Magnetic feature Error
E04/E05
IR feature Error
E06
Thickness Error
E07
Slant note
E08
Hologram Error
E09/E10/E11/E12
Paper quality Error
E20
Passing Error
Important Notices
1.
If the machine keeps alarm or works abnormally, check the following: Whether the
main power supply is within specified range (AC 100V~240V/50~60Hz). Whether the
DC output is within specified range: DC 12V±5%. Whether the supply plug is well
connected. Whether the built-in battery is sufficient to work. Clear the dust on the
sensors.
2.
If a banknote is blocked while it is being detected, please open the top cover and get
out the banknote to detect it again.
3.
Please smooth the banknote before detecting, and the banknote must be put in
straightly while it is being inserted.
Maintenance
This machine is precise financial detecting equipment that needs periodic
maintenance.
1.
Periodically check the voltage of the power supply to ensure that the voltage is
within the specified range.
2.
Keep the banknote detector in ventilated place and beyond strong sunshine and
magnetic field.