15
Assembly and installation manual
QIM/QDB Mixer Series
QIM/QDB-M01
3e. Using the 3/8” rod and the hexagonal socket and wrench to untighten the impeller
nut to remove the elements previously assembled. Take the impeller nut, impeller gasket,
impeller and impeller key off. Do not forget to remove also the spacer used to determinate
the stub shaft position. Continue assembling the mechanical seal (96). Figure I.
4. ASSEMBLING THE SINGLE MECHANICAL SEAL
4a. Place into the backplate the stationary face of the mechanical seal (96C) with its O-ring
(96F). First place the O-ring on the stationary face, remember that you can use water or
dishes soap to lubricate or glue O-rings and gaskets to the metal elements to facilitate
assembly, place both pieces in the inner housing of the backplate taking care that the
notch in the stationary face coincides with the backplate pin (96H). Push until the seal
surface fully seats on the surface of the housing. Figure J.
Figure I.
Figure J.
A
SS
EM
B