background image

2.6  Enroll & erase group member's fingerprint(s)

13

12

Fingerprint number & name list

G r o u p   A

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

0001

0002

0003

0010

0011

0012

0013

0020

0021

0022

0023

0030

0031

0032

0033

0100

0101

0102

0103

0110

0111

0112

0113

0120

0121

0122

0123

0130

0131

0132

3001

3002

3003

3010

3011

3012

3013

3020

3021

3022

3023

3030

3031

3032

3033

3100

3101

3102

3103

3110

3111

3112

3113

3120

3121

3122

3123

3130

3131

3132

1001

1002

1003

1010

1011

1012

1013

1020

1021

1022

1023

1030

1031

1032

1033

1100

1101

1102

1103

1110

1111

1112

1113

1120

1121

1122

1123

1130

1131

1132

2001

2002

2003

2010

2011

2012

2013

2020

2021

2022

2023

2030

2031

2032

2033

2100

2101

2102

2103

2110

2111

2112

2113

2120

2121

2122

2123

2130

2131

2132

Fingerprint

 

No. 

Name 

Fingerprint

 

Name 

Fingerprint

 

Name 

Fingerprint

 

Name 

G r o u p   B

G r o u p   C

G r o u p   D

ID For deleting Group 

A

:

0000

ID For deleting Group 

B

:

1000

ID For deleting Group 

C

:

2000

ID For deleting Group 

D

:

3000

QSE7F4 USER MANUAL

QSE7F4 USER MANUAL

2.6.1   Enroll group member's fingerprint(s)

2-6

 

Referring to the list, let's take the member in Group A, Fingerprint No. 0001 
for example.

1.Place Master finger on the sensor, the lock will be activated once the infrared 

detector detects the finger. 

The blue background lights, green indicator light 

and red light on sensor flashes; Or press “0”, the blue background green 

indicator light and red light on sensor flashes, place the Master finger on the 

sensor .(Figure2-6)

NOTE: A. If the infrared detector doesn't work, you can press “0” to activate 

the lock.

B. After the red light on sensor flashes, you must put the Master finger on the 

sensor within 5 seconds. Otherwise, the red indicator flashes, followed by 2 

short beeps to indicate the failed operation.

2.All indicators go out, a long beep is heard, move away the Master finger, the 

green and red indicators flash (NOTE: the flash will last about 6 seconds, step 3 

must be done within 6 seconds)

3.Press “1”, a long beep is heard, red indicator goes out, green indicator lights. 

(Figure2-7)

Summary of Contents for Fingerprint Plus QSE7F4

Page 1: ...no representa tions or warranties with respectto the contents hereof and specifically disclaims any impliedwarranties of selling or functionality for anyparticular purpose Digital Peripheral Solutions...

Page 2: ...echnical Parameters 1 3 2 Operating Environment 1 4 Components 1 5 Structure View 2 Operation Instruction 2 1 Left handedand Right handed 2 2 Status ofthe lock 2 3 Instruction forindicators 2 4 Functi...

Page 3: ...utside inside lever 2 6 2 How to erase group member fingerprint 2 7 Unlocking 2 7 1 Unlock with Emergency PIN 2 7 2 Unlock with group member fingerprint 2 7 3 Unlock with mechanical key 2 8 How to set...

Page 4: ...ds later the lock will alarm automatically While alarming the door can t be opened with fingerprint or Emergency PIN but can be opened with mechanical key after 1 minute s alarming the alarm stops the...

Page 5: ...e fingerprint template All enrolled fingerprint template will be saved while replacing the batteries 120 max Sunlight resistable Remain good condition after being jabbed with a 4H pencil at a 20cm s d...

Page 6: ...if the hinge is on the right it is right handed lock 2 1 2 1 Left handed and Right handed 2 2 Status of the lock 1 Operation Instruction 1 Lock status locked with latches not by deadbolt Figure 2 1 Le...

Page 7: ...Activate the lock in the manual it means to make the buttons or sensor begin to work Button 0 TO ACTIVATETHE LOCK QSE7F4 USER MANUAL QSE7F4 USER MANUAL 2 5 1 How to set Master fingerprint 2 3 2 4 2 5...

Page 8: ...linput for Emergency PIN NOTE After entering the first digit all red indicators change to green indicator lights 4 Repeat entering the same 8 digit PIN green indicator goes out followed by a QSE7F4 US...

Page 9: ...Group B 1000 ID For deleting Group C 2000 ID For deleting Group D 3000 QSE7F4 USER MANUAL QSE7F4 USER MANUAL 2 6 1 Enroll group member s fingerprint s 2 6 Referring to thelist let s takethe member inG...

Page 10: ...n each lock B Master fingerprintand the groupmember fingerprint cannotbe the same C Afingerprint number willonly allow toenroll one fingerprint D Group memberfingerprint can openthe lock QSE7F4 USER M...

Page 11: ...1 minute automatically 2 Blue background and green indicator light up a long beep is heard the inside motor is activated 3 Rotate the outside lever to unlock Figure2 9 QSE7F4 USER MANUAL QSE7F4 USER...

Page 12: ...SE7F4 USER MANUAL 2 13 2 9 Change batteries flashes once for a second which indicates the lock is set into Normally open status successfully 3 Unlock with Emergency PIN or group member fingerprint aga...

Page 13: ...ng tools not provided aresuitable for installingthis lock 21 20 1pc Electric drill Socket 1pc Drill bit 1pc File 1pc Square ruler 1pc Knife 1pc Hammer 1pc Drill 1pc Chisel 1pc Screwdriver 1pc Pencil 1...

Page 14: ...plate on the door make the spindle on the front plate through the cylinder 5 Connect the data cable in front plate with back plate fix the back plate with 2 pcs of M5 screws and 1pc of M6 screw 6 Put...

Page 15: ...ws two short beeps door can t be opened 1 Invalid fingerprint key 2 Your fingerprint has already been deleted 1 Your fingerprint position is quite different from where you first enrolled 2 Bad quality...

Page 16: ...021 3022 3023 3030 3031 3032 3033 3100 3101 3102 3103 3110 3111 3112 3113 3120 3121 3122 3123 3130 3131 3132 1001 1002 1003 1010 1011 1012 1013 1020 1021 1022 1023 1030 1031 1032 1033 1100 1101 1102 1...

Reviews: