DMX in/LedSync out

Use these connectors when the driver is used in a DMX network. For DMX in, connect the network 

cable’s DMX+, DMX- and DMX shielding wire (the orange/white, orange and brown wire in a CAT5 

cable) to the DMX in+, DMX in- and DMX in shield connector respectively. For LedSync out, connect 

the network cable’s DMX+, DMX- and DMX shielding wire to the LedSync out+, LedSync out-  and 

LedSync shield connector respectively. DMX Shield must be grounded to Earth Ground at a single 

point external to power supply

BOTTOM

BK

Black Powder Coat 

SS

316 Marine Grade

Stainless Steel

Finish ( Standard ) 

 

 
 

 

 

1.07"

1.36"

4.90"

M

-

+

M

-

+

M

-

+

TOP TRAY

5

  Knockouts of 

1.07"

 

Hole for 

3/4"

 fitting

4

  Knockouts of 

1.36"

 

Hole for 

1"

 fitting

14.5"

15.4"

9.22"

HOUSING

● 

18 gauge Welded Steel Enclosure: 9.22"W x 15.4"H x 4.90"D

● Door: 9.27"W x 14.5"H

● K

nockouts: 9

● Built-

in support bracket incorporated to secure housing for surface mounting 

FEATURES

 Limited output voltage and current, plus isolation for safe operation 

● F

ully potted driver(s) for moisture resistance

● Controllable with DMX decoder module

● Control 4 LED channels with DMX

● Surface mount only

● Suitable for dr

y, damp and wet locations 

● Suitable for Use with Submersible Luminaire

● Primary Voltage - Universal (120-277V )

● Wide operating temperature range: 

-4 degF to 122 degF

● F

it

s up to (3):100W 24 VDC driver(s) and DMX decoder module(s)

● Driver has Class A sound rating

● DMX dimming down to 0%

● Class 2 Output 

● 5 year warranty

    Low Voltage Lighting Systems

   

    :  CSA Class 3425-15 and Class 3425-95               

    :  CSA Standard C22.2 No. 250.0-08 - Luminaires               

    :  ANSI/ UL Standard 

2108 - Low V

oltage Lighting Systems    

    :  CSA Std C22.2 No 250.13-14 - Light Emitting Diode (LED) Equipment for Lighting Applications    

    :  ANSI/ UL Standar

d 87

50 - Light Emitting Diode (LED) Equipment for Use in Lighti

ng Pr

oducts

   

 LED Landscape Lighting Systems

   

    :  CSA Class 3402-15 and Class 3402-95               

    :  CSA Standard C22.2 No. 25

0.7-07 - Extra-Low-Voltage Landscape Lighting Systems   

            

    :  ANSI/ UL Standard 

1838 - Low Voltage Landscape Lighting Systems

    

    :  CSA Std C22.2 No 250.13-14 - Light Emitting Diode (LED) Equipment for Lighting Applications    

    :  ANSI/ UL Standar

d 87

50 - Light Emitting Diode (LED) Equipment for Use in Lighti

ng Pr

oducts

+

24

DMX

QOM-eLED

U

NV

2 Primary Voltage 

UNV: 120-277 Vrms

3 Secondary Voltage 

24VDC

DMX

 

DMX

Opts

Size

Model

Prim. V

Sec. V

Max Prim. 

@ 277V

1 Size

 

Max Load

(Watts)

Max Prim. 

Amp

s

@ 120V

Max Prim. 

Amp

s

@ 277V

Secondary

Voltage(24VDC)

 

 
 

 

 

 

4 DMX

5 Options

QOM-eLED-100-UNV/24+DMX

Ordering Example

ORDERING GUIDE

BOTTOM TRAY

PRIMARY

SECONDARY

LED DRIVER 2

  (120V - 277V)

LED DRIVER 1

  (120V - 277V)

LED DRIVER 3

  (120V - 277V)

NEU

GND

HOT

W B G R+24 W B G R+24

W B G R+24 DMX

 

 
 

24VDC

24VDC

24VDC

0.95 A

1.90 A

2.85 A

0.40 A

0.80 A

1.20 A

1x100W          

2x100W

3x100W

100W

200W

300W

© 2019, Q-Tran Inc.  155 Hill St. Milford, CT 06460. All rights reserved - 203-367-8777  -  sales@q-tran.com  -  www.q-tran.com 

QOM-eLED+DMX

1

Summary of Contents for QOM-eLED+DMX

Page 1: ...203 367 8777 sales q tran com www q tran com Wear rubber shoes and work on a sturdy wooden or fiberglass ladder This power supply must be installed according to the National Electric Code and local codes and ordinances This power supply is to be installed and serviced only by an licensed electricians This power supply is to be installed so that it is not likely to be contacted by people To avoid a...

Page 2: ...VDC driver s and DMX decoder module s Driver has Class A sound rating DMX dimming down to 0 Class 2 Output 5 year warranty Low Voltage Lighting Systems CSA Class 3425 15 and Class 3425 95 CSA Standard C22 2 No 250 0 08 Luminaires ANSI UL Standard 2108 Low Voltage Lighting Systems CSA Std C22 2 No 250 13 14 Light Emitting Diode LED Equipment for Lighting Applications ANSI UL Standard 8750 Light Emi...

Page 3: ...Inc 155 Hill St Milford CT 06460 All rights reserved 203 367 8777 sales q tran com www q tran com 2 Distances are based on a 5 Voltage drop max This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved VDC 10 AWG 12 AWG 14 AWG 16 AWG 18 AWG 20 AWG 22 AWG 24 AWG 26 AWG 5 6mm2 3 ...

Page 4: ...n t have a controller yet how can I keep my lights on Change the Mode to COLR This allows to manually set a specific color to be on Adjust the Hue or WHIT to achieve the desired color This sets that specific color 3 My LEDs aren t coming out the right color They look like white has been added in Verify the Network Resolution NETW RES Default is 8 BT Check your DMX Programming Stick controllers com...

Page 5: ...P LOG LIN Dimming curve M DIM CURV 00 20 M display off SHOW M M M 99 99 0 255 Intensity Speed Show SPD INT M HUE M HUE White WHIT M M Intensity 0 255 INT display off 0 1535 0 255 M M M 1 512 Network resolution DMX address 8 BT 16 BT display off ADDR DMX RES NETW M Interpolation OFF VID COLR WHIT GLOW INTERPOL Other features Visual test run Locking the configuration Reset to factory defaults M disp...

Page 6: ...All rights reserved 203 367 8777 sales q tran com www q tran com A C LED DRIVER 2 120 277V B LED DRIVER 2 120 277V B LED DRIVER 2 120 277V B M M M QOM eLED DMX for exterior SECONDARY PRIMARY DMX Shield DMX DMX M iQ LED Blue Blue White White Green Green Red Red Black 24V W B G R 24V W B G R 24 W B G R 24 W B G R 24 NEU GND HOT DMX W B G R 24 iQ LED iQ LED iQ LED GND HOT NEU ...

Page 7: ...roduct must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved CE PRODUIT DOIT ÊTRE INSTALLÉ SELON LE CODE D INSTALLATION PERTINENT PAR UNE PERSONNE QUI CONNAÎT BIEN LE PRODUIT ET SON FONCTIONNEMENTAINSI QUE LES RISQUES INHÉRENTS Suitable For Indoor Or Outdoor Use Wall Mount Only INSTALLA...

Reviews: