background image

QTM-eLED+DALI-DT6

  

 

LED POWER SUPPLY 100W–300W

© 2022 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | sales@q-tran.com | www.q-tran.com 

Specification subject to change. Rev-11-15-22

COMPLIANT

Part Number Builder

QTM-eLED+DALI-DT6 is an LED power supply for DALI 2 applications. 

It utilizes a 100W constant voltage LED Driver from Thomas Research 

and DALI 2 DT-6 Decoders. The unit is available in 100-300 watt 

capacity. The power supplies and decoders are all prewired together 

along with terminal blocks for power and control wires. The housing 

can be recessed or surface mounted.

Technical Information

QTM-eLED

UNV

24VDC

DALI-DT6

WH (Standard)

BK

100W

200W

300W

2-Wire

3-Wire

N/A

N/A

2-Wire

3-Wire

2-Wire

3-Wire

N/A

2-Wire

3-Wire

2-Wire

3-Wire

2-Wire

3-Wire

Size

Size

Max Load  

(Watts)

Secondary 

Voltage

(12/24VDC)

Max Prim Amps 

@ 120V

Max Prim Amps 

@ 277V

100W

1x100W

24VDC

0.95A

0.40A

200W

2x100W

24VDC

1.90A

0.80A

300W

3x100W

24VDC

2.85A

1.20A

Voltage Drop Chart

VDC

Watts 

(W)

10 AWG 

(5.6mm2)

12 AWG 

(3.3mm2)

14 AWG 

(3.0mm2)

16 AWG 

(1.3mm2)

18 AWG 

(0.78mm2)

20 AWG 

(0.50mm2)

22 AWG 

(0.33mm2)

24 AWG 

(0.22mm2)

26 AWG 

(0.13mm2)

24

17
25
40
80

100

897'
567'
309'
130'

84'

564'
356'
194'

82'
53'

355'
224'
122'

51'
33'

223'
141'

77'
32'
21'

140'

88'
48'
20'
13'

88'
56'
30'
13'

8'

55'
35'
30'

8'
5'

35'
22'
12'

5'
3'

22'
14'

7'
3'

*Distances are based on a 5% Voltage drop max.

• This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved

Product

Prim. V

Sec. V

Control

Color

3

Size

1

Output Wiring 1

2

Output Wiring 2

2

Output Wiring 3

2

Output Wiring Options

2-Wire Light Engines:

 SW, SW-HE, SW-HE+, SD-SW, SC, WD

3-Wire Light Engines: 

DW, DW-HE

Color

WH: 

White (Standard)

BK

Black Powder Coat Finish

NOTE:

2-Wire default is 1 address
3-Wire default is 2 addresses
For customization or pre-programming contact a local sales rep.
DALI commissioning to be performed by a third party at time of installation.

Summary of Contents for QTM-eLED+DALI

Page 1: ...0W 24VDC 0 95A 0 40A 200W 2x100W 24VDC 1 90A 0 80A 300W 3x100W 24VDC 2 85A 1 20A Voltage Drop Chart VDC Watts W 10 AWG 5 6mm2 12 AWG 3 3mm2 14 AWG 3 0mm2 16 AWG 1 3mm2 18 AWG 0 78mm2 20 AWG 0 50mm2 22 AWG 0 33mm2 24 AWG 0 22mm2 26 AWG 0 13mm2 24 17 25 40 80 100 897 567 309 130 84 564 356 194 82 53 355 224 122 51 33 223 141 77 32 21 140 88 48 20 13 88 56 30 13 8 55 35 30 8 5 35 22 12 5 3 22 14 7 3 ...

Page 2: ...277V LED DRIVER 120V 277V LED DRIVER 120V 277V BOTTOM TRAY PRIMARY SECONDARY DALI OUT NEU HOT GND DALI IN TOP TRAY 875 4 00 BOTTOM NOTE 16 additional side knockouts 9 Knockouts of 0 875 Hole for 1 2 fitting V V V V 12 36VDC IN LED groups D1 D2 D1 D2 DALI Signal in out 1 2 3 4 V V V V 12 36VDC IN LED groups D1 D2 D1 D2 DALI Signal in out 1 2 3 4 V V V V 1 2 3 4 12 36VDC IN LED groups D1 D2 D1 D2 DA...

Page 3: ...277 Input Current max Arms 0 98 0 51 0 43 Inrush Current max Apk 20 Input Frequency Hz 50 60 Input Power W 117 Environmental Min Nom Max THD 20 PF 0 90 Case Temp ºC 90 200us event 0 20 40 60 80 100 120 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Life Time kHrs Case Temperature ºC Life Time vs Case Temperature Output Current A 120Vrms 277Vrms 23 4 23 5 23 6 23 7 23 8 23 9 24 24 1 24 2 0 0 5 1 1 5 2 2...

Page 4: ...can be changed over the 2 button user interface Wiring Diagram To DALI Controller V V V V 1 2 3 4 12 36VDC IN LED groups D1 D2 D1 D2 DALI Signal in out D1 D2 D1 D2 12 36VDC IN 2 1 0 2 1 5 mm2 0 35 inch 0 5 1 5 mm2 AWG 20 16 0 35 inch AWG 24 16 VDC and LED connectors Other connectors LED V V V V 1 2 3 4 12 36VDC IN LED groups D1 D2 D1 D2 DALI Signal in out V V V V 1 2 3 4 12 36VDC IN LED groups D1 ...

Page 5: ... work on a sturdy wooden or fiberglass ladder This power supply must be installed according to the National Electric Code and local codes and ordinances This power supply is to be installed and serviced only by an licensed electricians This power supply is to be installed so that it is not likely to be contacted by people To avoid a hazard to children account for all parts and destroy all packagin...

Page 6: ...FACE SPACING SURFACE STACKING ROD SUSPENSION 9 5 O C 16 O C 19 O C 9 5 O C 9 5 O C More Units can be stacked More Units can be stacked More Units can be stacked NOTE Rods not included RECESSED SURFACE ROD SUSPENSION Horizontal ROD SUSPENSION Vertical Double Sided Key Hole 1 4 Rod Thru Hole 3 8 Rod Thru Hole NOTE Bracket can also be mounted Top Bottom for Vertical Mounts 0 875 KNOCKOUT 9X FOR 1 2 F...

Page 7: ... 3 Wire default is 2 address Connecting and Configuring the DALI DT6 Decoder To DALI Controller V V V V 1 2 3 4 12 36VDC IN LED groups D1 D2 D1 D2 DALI Signal in out D1 D2 D1 D2 12 36VDC IN 2 1 0 2 1 5 mm2 0 35 inch 0 5 1 5 mm2 AWG 20 16 0 35 inch AWG 24 16 VDC and LED connectors Other connectors LED V V V V 1 2 3 4 12 36VDC IN LED groups D1 D2 D1 D2 DALI Signal in out V V V V 1 2 3 4 12 36VDC IN ...

Page 8: ...2 Press and hold either button Use the buttons to set address 1 2 Set Address 5 sec 2 Set LED groups Changing LED group 1A SW 2A TW 1 2 Press and hold both button Use the first button to set the amount of addresses 5 sec 1 Locking the configuration Confirm 1 2 Press and hold either button 5 sec 2 Reset to factory defaults Reset 1 2 1 2 Set Address Press and hold either button 5 sec Use the buttons...

Page 9: ...D HOT DALI IN DALI OUT V V V V 1 2 3 4 12 36VDC IN LED groups D1 D2 D1 D2 DALI Signal in out V V V V 12 36VDC IN LED groups D1 D2 D1 D2 DALI Signal in out V V V V 12 36VDC IN LED groups D1 D2 D1 D2 DALI Signal in out SECONDARY PRIMARY DA DA Red 24V Black Negative LEAD WIRE 1 2 3 4 1 2 3 4 NEU GND HOT DA DA Red Blue To next power supply LED LED LED DALI Controller By others DALI Bus Power Supply By...

Page 10: ...ur au moins 60C Suitable For Damp Locations CONVIENT AUX EMPLACEMENTS HUMIDES Class 2 Classe 2 CLASS 3425 95 3402 95 QTM eLED 100 DALI QTM eLED 200 DALI QTM eLED 300 DALI 0 95 0 40 1 90 0 80 2 85 1 20 50 60 50 60 50 60 24 24 24 100 200 300 120 277 120 277 120 277 Model Input Voltage V Frequency Nominal Output Voltage VDC Nominal Output Wattage W Input Current A 120V 277V INPUT VOLTAGE OUTPUT VOLTA...

Reviews: