Black Wire = +24V
Red Wire = Red LED
Green Wire = Green LED
Blue Wire = Blue LED
White Wire = White LED
LED
M
-
+
LED
W
B
G
R
+24
TC
1
2
3
Group
Group
Group
Group
LED
4
GND
HOT
NEU
LED DRIVER (120 - 277V)
NEU
GND
HOT
Ext in + Ext in
DMX in +
DMX in -
DMX in shield
LedSync thru +
LedSync thru -
LedSync shield
-
DMX in shield
DMX in -
DMX in +
DMX
To DMX Controller
Ext in +
Ext in
DMX in +
DMX in -
DMX in shield
LedSync thru +
LedSync thru -
LedSync shield
LINEARdrive 180D
-
12-28V / 6
A Direct voltage controlled LED driver
Ext in +
Ext in
DMX in +
DMX in -
DMX in shield
LedSync thru +
LedSync thru -
LedSync shield
LINEARdrive 180D
-
12-28V / 6
A Direct voltage controlled LED driver
DMX in shield LedSync shield
DMX in -
LedSync thru -
DMX in + LedSync thru +
Blue Wire = Blue LED
Red Wire = Red LED
Green Wire= Green LED
White Wire = White LED
Black Wire = +24V
A
C
LED DRIVER 2
(120 - 277V)
B
M
-
+
SECONDARY
PRIMARY
DMX Shield
DMX -
DMX +
-
+
LED
Blue = Blue
White = White
Green = Green
Red = Red
Black = +24V
W B G R +24
W B G R +24
DMXOUT DMXIN
NEU
GND
HOT
LED
M
-
DMX in +
DMX in -
DMX Shield
LedSync thru +
LedSync thru -
LedSync Shield
DMXIN DMXOUT
GND
HOT
NEU
LED DRIVER
(120 - 277V)
NEU
GND
HOT
GND
DMX +
DMX -
Red
Blue
Green
To next
power
supply
GND
HOT
NEU
WARNING:
Risk of electrical shock. May result in serious injury or death. Disconnect power before servicing or installing.
CAUTION:
The device may only be connected and installed by a qualified electrician. All applicable regulations, legislation and building codes must be observed.
Incorrect installation of the device can cause irreparable damage to the device and the connected LEDs.
●
DMX Shield must be grounded to Earth Ground at a single point external to power supply
Connecting and configuring the LINEARdrive 100D/180D
QTM - eLED+DMX
Connecting &
Configuration
Instruction
Secondary Wiring
4
DMX connections
Primary Wiring
Control Wiring
Commonly Asked Questions
1)
How can I verify my installation?
●
Apply AC input, verify display turns on
:
This confirms AC input wiring
● Run “Visual Test Run” : This verifies wiring of LEDs. Make sure LEDs turning on go
in
same order as the Test Run
2)
I don’t have a controller yet, how can I keep my lights on?
● Change the Mode to “COLR” : This allows to manually set a specific color to be on
● Adjust the Hue or WHIT to achieve the desired color : This sets that specific color
3)
My LEDs aren’t coming out the right color. They look like white has been
added in
● Verify the Network Resolution “NETW RES” : Default is 8 BT
● Check your DMX Programming. Stick controllers come with RGB programs by default.
This will cause RGBW LEDs to show Pink vs. Red
© 2020, Q-Tran Inc. 155 Hill St. Milford, CT 06460. All rights reserved - 203-367-8777 - sales@q-tran.com - www.q-tran.com