background image

  

Black Wire = +24V
Red Wire = Red LED
Green Wire = Green LED
Blue Wire = Blue LED
White Wire = White LED

LED 

M

-

+

LED 

W

B

G

R

+24

TC

1

2

3

Group

Group

Group

Group

LED

4

  

GND

HOT

NEU

LED DRIVER   (120 - 277V)

NEU

GND

HOT

  

Ext in + Ext in

DMX in +

DMX in -

DMX in shield

LedSync thru +

LedSync thru -

LedSync shield

 -

DMX in shield

DMX in - 

DMX in +

DMX

To DMX Controller

Ext in +

Ext in

DMX in +

DMX in -

DMX in shield

LedSync thru +

LedSync thru -

LedSync shield

LINEARdrive 180D

 -

12-28V / 6

A Direct voltage controlled LED driver

Ext in +

Ext in

DMX in +

DMX in -

DMX in shield

LedSync thru +

LedSync thru -

LedSync shield

LINEARdrive 180D

 -

12-28V / 6

A Direct voltage controlled LED driver

DMX in shield         LedSync shield
DMX in -  

       LedSync thru -

DMX in +                   LedSync thru +

Blue Wire   = Blue LED

Red Wire   = Red LED

Green Wire= Green LED

White Wire = White LED

Black Wire = +24V

A

C

LED DRIVER 2

  (120 - 277V)

B

M

-

+

SECONDARY

PRIMARY

DMX Shield
DMX -

DMX +

-

+

LED 

Blue = Blue

White = White

Green = Green

Red = Red

Black = +24V

W B G R +24

W B G R +24

DMXOUT DMXIN

NEU

GND

HOT

LED 

M

-

DMX in +

DMX in -

DMX Shield

LedSync thru +

LedSync thru -

LedSync Shield

DMXIN DMXOUT

GND

HOT

NEU

LED DRIVER

  (120 - 277V)

NEU

GND

HOT

GND

DMX +
DMX -

Red
Blue
Green

To next 

power 

supply

GND

HOT
NEU

WARNING:

 Risk of electrical shock. May result in serious injury or death. Disconnect power before servicing or installing. 

CAUTION:

 The device may only be connected and installed by a qualified electrician. All applicable regulations, legislation and building codes must be observed. 

                       Incorrect installation of the device can cause irreparable damage to the device and the connected LEDs. 

 

    

 DMX Shield must be grounded to Earth Ground at a single point external to power supply

Connecting and configuring the LINEARdrive 100D/180D

QTM - eLED+DMX

Connecting & 

Configuration

 Instruction

  

Secondary Wiring

4

DMX connections 

Primary Wiring

Control Wiring

Commonly Asked Questions

1)

 How can I verify my installation?

 Apply AC input, verify display turns on 

This confirms AC input wiring

● Run “Visual Test Run” : This verifies wiring of LEDs.  Make sure LEDs turning on go 

in 

    same order as the Test Run

2)

 I don’t have a controller yet, how can I keep my lights on? 

● Change the Mode to “COLR” : This allows to manually set a specific color to be on

● Adjust the Hue or WHIT to achieve the desired color  : This sets that specific color

3)

 My LEDs aren’t coming out the right color. They look like white has been

 added in

● Verify the Network Resolution “NETW RES”  : Default is 8 BT

● Check your DMX Programming.  Stick controllers come with RGB programs by default. 

    This will cause RGBW LEDs to show Pink vs. Red

© 2020, Q-Tran Inc.  155 Hill St. Milford, CT 06460. All rights reserved - 203-367-8777  -  sales@q-tran.com  -  www.q-tran.com

Summary of Contents for QTM-eLED+DMX

Page 1: ...AGE LIGHTING SYSTEM QTM eLED DMX COMPLIANT Wear rubber shoes and work on a sturdy wooden or fiberglass ladder This power supply must be installed according to the National Electric Code and local codes and ordinances This power supply is to be installed and serviced only by an licensed electricians This power supply is to be installed so that it is not likely to be contacted by people To avoid a h...

Page 2: ...ons Suitable for surface or recessed mounting use Primary Voltage Universal 120 277V Wide operating temperature range 4 degF to 122 degF Fits up to 3 100W 24 VDC driver s and DMX decoder module s DMX dimming down to 0 Driver has Class A sound rating Class 2 Output 5 year warranty CSA 239924 Low Voltage Lighting Systems CSA Class 3425 15 and Class 3425 95 CSA Standard C22 2 No 250 0 08 Luminaires A...

Page 3: ...hese connectors when the driver is used in a DMX network For DMX in connect the network cable s DMX DMX and DMX shielding wire the orange white orange and brown wire in a CAT5 cable to the DMX in DMX in and DMX in shield connector respectively For LedSync out connect the network cable s DMX DMX and DMX shielding wire to the LedSync out LedSync out and LedSync shield connector respectively DMX Shie...

Page 4: ...SED MOUNT Plenum Door Required Horizontal Vertical SURFACE SPACING SURFACE STACKING ROD SUSPENSION 9 5 O C 16 O C 19 O C 9 5 O C 9 5 O C More Units can be stacked More Units can be stacked More Units can be stacked NOTE Rods not included RECESSED SURFACE ROD SUSPENSION Horizontal ROD SUSPENSION Vertical VERTICAL QTM eLED DMX Housing Mounting Options 3 2020 Q Tran Inc 155 Hill St Milford CT 06460 A...

Page 5: ...injury or death Disconnect power before servicing or installing CAUTION The device may only be connected and installed by a qualified electrician All applicable regulations legislation and building codes must be observed Incorrect installation of the device can cause irreparable damage to the device and the connected LEDs DMX Shield must be grounded to Earth Ground at a single point external to po...

Page 6: ...UE M HUE White WHIT M M Intensity 0 255 INT display off 0 1535 0 255 M M M 1 512 Network resolution DMX address 8 BT 16 BT display off ADDR DMX RES NETW M Interpolation OFF VID COLR WHIT GLOW INTERPOL Other features Visual test run Locking the configuration Reset to factory defaults M display off TEST Test R 1 sec G 1 sec B 1 sec W 1 sec RGBW 1 sec R 1 sec G 1 sec B 1 sec W 1 sec RGBW 1 sec displa...

Page 7: ...Shield DMX DMX M LED Blue Blue White White Green Green Red Red Black 24V W B G R 24V NEU GND HOT GND HOT NEU A B C 6 for interior QTM eLED DMX QTM eLED DMX Wiring Installation 2020 Q Tran Inc 155 Hill St Milford CT 06460 All rights reserved 203 367 8777 sales q tran com www q tran com W B G R 24 W B G R 24 W B G R 24 DMX IN DMXOUT A B C LED LED LED GND DMX DMX Red Blue Green To next power supply ...

Page 8: ...24 24 24 100 200 300 QTM eLED 60 QTM eLED 120 QTM eLED 180 120 277 120 277 120 277 0 60 0 29 1 20 0 58 1 80 0 87 50 60 50 60 50 60 12 12 12 60 120 180 Q Tran Inc Q TRAN INC MILFORD CT U S A 203 367 8777 WWW Q TRAN COM CLASS 3425 15 3425 95 LOW VOLTAGE LIGHTING SYSTEM Type Ic Recessed Inherently Protected Type IC ENCASTRE PROTECTION INHÉRENTE For Supply Connections Use Wire Rated For At Least 60 C ...

Reviews: