background image

29

Manufactured for Qardio, Inc. California, USA. 

www.getqardio.com

Kahl Handelsvertretung

Add.: Isarstr.33 40699 Erkrath, Germany

Qardio Europe Ltd.

14-16 Dowgate Hill, London, EC4R 2SU

United Kingdom

Type BF Applied Part (cuff)

WEEE

2014 

US Importer 

YA HORNG ELECTRONIC CO., LTD.

Tainan, Taiwan

Factory: ATTEN ELECTRONIC (DONGGUAN) CO., LTD.

188 Industrial District, Ping Shan Administrative District,

Tang Shia Town, Dongguan, 190, CN, 518055

Read this manual before use.

0434

0434

0434

0434

0434

0434

0434

0434

FCC ID: 2ABF2-888ARM

IC: 11885A-888ARM00

Qardio, Inc. 340 S Lemon Ave #1104F,

Walnut, California 91789, USA.

Summary of Contents for QardioArm

Page 1: ...ARTER READ ON BLOOD PRESSURE User Guide DE Bedienungsanleitung FR Guide d utilisation ES Guia del usuario IT Guida utente NL Gebruikershandleiding PT Guia do usu rio RU Download www getqardio com manu...

Page 2: ...8 Detailed instructions on taking a blood pressure measurement 9 Checklist for measuring your blood pressure correctly and reliably 10 The traffic light indicator 10 Selecting multiple measurements a...

Page 3: ...y and precautions cleaning 17 AAA alkaline batteries usage storage 18 Irregular Heart Beat Message 18 Customer service contact 19 Limited warranty 19 Error messages and troubleshooting 20 QardioArm te...

Page 4: ...perior quality design and technology that can change your life for the better With its ease of use and accuracy QardioArm is ideal for monitoring your blood pressure in your home office or wherever is...

Page 5: ...ease read the User Guide carefully before using the QardioArm blood pressure monitor In the case of pregnancy arrhythmia and arteriosclerosis consult your doctor before use PACKAGE CONTENTS QardioArm...

Page 6: ...touch your device to the QardioArm to perform the pairing of your QardioArm with your phone or tablet When prompted accept the pairing request 6 On the Qardio app press the green START button to initi...

Page 7: ...You should fit the cuff closely but not too tight you should be able to insert a finger between the arm and the cuff 5 Make sure that the cuff is positioned about 2 cm or 1 inch above the elbow and yo...

Page 8: ...h as a desk or a table 3 The middle of the cuff should be at the level with your heart Lying Down During Measurement 1 Lie on your back 2 Straighten your arm along the side with your hand palm side up...

Page 9: ...pressure measurement with the QardioArm is easy and is done in a few simple steps until the measurement result is displayed Breathe normally and do not talk When the correct pressure is reached the i...

Page 10: ...over the artery The Qardio logo should be on the bottom towards your hand Support your arm so it is relaxed and ensure the QardioArm is at the same height as your heart Your arm should remain slightl...

Page 11: ...f measurements and the pause between measurements which is set at 30 seconds by default When the Multiple Measurement Averaging feature is on the individual results during the measurement are not disp...

Page 12: ...Besides medication weight loss and exercise can also help to lower your blood pressure You should never alter the dosages of any medications prescribed by your doctor Blood pressure is subject to wid...

Page 13: ...diagnosis of your health condition BLOOD PRESSURE CLASSIFICATION Systolic BP mmHg Diastolic BP mmHb COLOR INDICATOR Optimal 120 80 Green Normal 120 129 80 84 Green High Normal 130 139 85 89 Green Grad...

Page 14: ...es at the same time Use 4 new long life 1 5V size AAA batteries Do not use batteries beyond their expiration date and do not use rechargeable batteries To replace batteries 1 Release the batteries com...

Page 15: ...tery compartment hatch You should see a green light shining through Use a paper clip to press reset button If necessary go into the Settings of your phone or tablet select the QardioArm and select For...

Page 16: ...potentially dangerous You should always consult your doctor People with severe blood flow problems or blood disorders should consult a doctor before using the blood pressure monitor as cuff inflation...

Page 17: ...cannot express their consent to use Do not inflate the arm cuff when it is not wrapped around your arm Do not wrap the cuff inside out Do not apply strong shocks and vibrations to the QardioArm blood...

Page 18: ...ries when they are depleted Always replace all four AAA alkaline batteries at the same time do not use new and old AAA alkaline batteries together If the QardioArm blood pressure monitor will not be u...

Page 19: ...xchange the product with a functionally equivalent product that is new or equivalent to new in performance and reliability or 3 refund the original purchase price This warranty excludes damage resulti...

Page 20: ...d START button is gray not green During the measurement error signals were auto detected by the device or the pulse signals on the cuff are too weak QardioArm is not connected to your smartphone or ta...

Page 21: ...ent noise interference user talking user movements cuff not correctly fastened cuff broken pump or valve failure pressure overflow or other special characteristics of the user An adequate pressure can...

Page 22: ...te Please consult your physician for accurate assessment Though the batteries are installed the START button on the Qardio app is still gray Irregular heartbeat Batteries are not inserted correctly Ba...

Page 23: ...consistent times and locations Discuss your blood pressure values with your physician 2 If the problem occurs again please contact customer service Replace batteries according to instructions If the p...

Page 24: ...pressure 1 beat min for pulse Power Source 4 x 1 5V Batteries size AAA supplied Operating Conditions 10 40C 50 104F temperature 15 90 relative maximum humidity atmospheric pressure 86Kpa 106kpa maxim...

Page 25: ...mative documents COUNCIL DIRECTIVE 93 42 EEC of 14 June 1993 concerning medical devices as amended by Directive 2007 47 EC EN ISO 13485 2003 AC 2009 Medical devices Quality management systems Requirem...

Page 26: ...060 2 2009 Non invasive sphygmomanometers Part 2 Clinical validation of automated measurement type FCC STATEMENT Federal Communications Commission FCC Statement 15 21 You are cautioned that changes or...

Page 27: ...cified may result in increased emissions or decreased immunity The device uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interfer...

Page 28: ...ioArm Wireless Blood Pressure Monitor uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment...

Page 29: ...ype BF Applied Part cuff WEEE 2014 US Importer YA HORNG ELECTRONIC CO LTD Tainan Taiwan Factory ATTEN ELECTRONIC DONGGUAN CO LTD 188 Industrial District Ping Shan Administrative District Tang Shia Tow...

Page 30: ...lood Pressure Monitor system should assure that it is used in such an environment Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Conducted RFIEC 61000 4 6 3 V...

Page 31: ...should be that of a typical commercial or hospital environment Surge IEC 61000 4 5 1 kV differential mode 2 kV common mode N A Mains power quality should be that of a typical commercial or hospital e...

Page 32: ...arks of Google Inc The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG Inc and any use of such marks by Qardio Inc is under license Other trademarks and trade names are...

Reviews: