background image

Charging Tips

To Prevent Damage to Spot/flood light and Battery:

Do not attempt to use spot/flood light while charging directly from AC
outlet. Doing so may cause damage to battery and AC charger.

12-volt DC charger/adapter operates from a cigarette lighter receptacle
for charging battery in spot/flood light only while vehicle engine is
running or continuous corded operation with or without battery.

Do not attempt to charge battery pack using both AC an DC chargers
at the same time.

Only use charging devices that are provided with the Q-Beam Max
Million™ 

IIII

Rechargeable Spot/Flood Light or its replacements.

For DC Charger/Adapter -

Battery charges only while vehicle engine 

is running. 

For AC Charger -

Allow battery to fully charge. L.E.D. indicator on

battery will automatically turn off when battery is fully charged. 

See chart for recommended charge times.

Do not allow battery to completely discharge. A dim light indicates a
low battery. Recharge battery as soon as possible after each use.

Always keep the battery fully charged when not in use.

 

 

 

10

4

6

8

10

 

 

 20

DC Charge

AC Charge

USAGE

(Minutes)

CHARGE TIME (Hours)

Charge Times

Charge times are dependent on usage of the 

product. See chart below for recommended charge times.

6

To Replace Cigarette
Lighter Plug Fuse

Lighter Plug

Lighter Cap

Lighter Plug

Lighter Plug

Lighter Cap

Fuse

Fuse Holder

Lighter Cap

Lighter Cap

Step 1:

Disconnect spot/flood light from power source.

Step 2:

Unscrew cap of lighter plug and pull straight away from fuse.

Step 3:

Pull fuse holder and fuse out of lighter plug. Observe to see if
fuse is burned out.

NOTE:

Use a 8A fuse only. Fuse is burned out when fuse element is
missing or broken inside glass tube. Replace with new 8A fuse
if fuse element is missing or broken.

Step 4:

Pull fuse out of fuse holder. Insert new fuse into holder.

Step 5:

Insert fuse holder and fuse into lighter plug.

Step 6:

Screw cap onto lighter plug.

INSTR_800-2655-3_MM2.qxd  9/26/05  10:32 AM  Page 7

Summary of Contents for Max Million II

Page 1: ...LOW ALL WARNINGS AND INSTRUCTIONS IN THIS MANUAL TO AVOID PERSONAL INJURY OR PROPERTY DAMAGE WARNING TO PREVENT DAMAGE TO EYESIGHT NEVER LOOK INTO SPOTLIGHT WHEN LIGHT IS ON DO NOT SHINE LIGHT INTO THE FACE OF SOMEONE ELSE INSTR_800 2655 3_MM2 qxd 9 26 05 10 32 AM Page 1 ...

Page 2: ...orroded DO NOT allow metal parts to touch metal contacts on battery as this can cause a short circuit and result in a fire DO NOT use an outdoor AC outlet to recharge battery To prevent accidental electrical shock we recommend this product always be charged on a GFCI Ground Fault Circuit Interrupter outlet Only use charging devices that are provided with the Q Beam Max Million I II I Rechargeable ...

Page 3: ...n use Step 1 Follow charging instructions on page 3 of this manual and allow battery to fully charge Step 2 Depress trigger switch in handle to turn spot flood light ON Release trigger switch to turn spot flood light OFF Step 3 To lock trigger switch to ON depress trigger switch and slide down lock button on side of handle To unlock and turn spot flood light OFF depress trigger and slide lock butt...

Page 4: ...harge times WARNING A damaged battery can leak acid Avoid contact with eyes and skin If contact occurs flush immediately with large amounts of water DO NOT ingest If contact with eyes or ingestion occurs consult physician immediately 3 To Charge 10 4 6 8 10 20 DC Charge AC Charge USAGE Minutes CHARGE TIME Hours Charge Times Charge times are dependent on usage of the product See chart below for rec...

Page 5: ...rger only Step 3 For AC Charger Allow battery to fully charge L E D indicator on battery will automatically turn off when battery is fully charged IMPORTANT If battery is not used for more than 90 days remove battery from the spot flood light Charge battery every 2 months to ensure battery does not completely lose charge A completely discharged battery may not recharge properly WARNING A damaged b...

Page 6: ... the connector firmly with fingers then pulling bulb wire straight out Step 13 To install new bulb grasp the bulb from the metal end DO NOT TOUCH THE GLASS PART and insert into the reflector mounting plate Align the slots in the bulb base with those in the reflector mounting plate Step 14 Replace wire retainer by pinching ends together while pressing down Push ends apart so they catch on the refle...

Page 7: ...w battery to completely discharge A dim light indicates a low battery Recharge battery as soon as possible after each use Always keep the battery fully charged when not in use 10 4 6 8 10 20 DC Charge AC Charge USAGE Minutes CHARGE TIME Hours Charge Times Charge times are dependent on usage of the product See chart below for recommended charge times 6 To Replace Cigarette Lighter Plug Fuse Lighter...

Page 8: ...anty please call Customer Service Department at 800 527 0717 for a Return Authorization Number and further instructions A receipt will be required Rechargeable lights returned to Brinkmann must include your name address and telephone number Please make sure the light is properly packed postage prepaid and insured A Return Authorization Number must be clearly marked on the outside of the box Brinkm...

Reviews: