z
z
z
z
z
z
z
27
Additional functions QL320HS and HV
The instrument type QL320 HS and HV can incline the laser plane in both
directions in manual mode.
Semi manual mode:
In the semi manual mode the Y-direction can be inclined while the X-direction
is still self levelling. The tilt control is activated appr. 20 seconds after
levelling.
Semi manual mode, to activate press the mode key twice
(lower LED lit)
Self levelling mode active in X-axis, the Y-axis can be
inclined with the up and down arrow keys
Indicates the direction that get inclined with the arrow
keys. In semi manual mode always the Y-axis.
Arrow keys to move the laser plane up or downwards in
Y direction.
The movement starts slowly, then increases speed.
The direction of the arrows corresponds to direction
marks on the housing.
The automatic tilt control will be active appr. 20 seconds after levelling. If the
laser is moved the rotor head stops and the upper level LED is lit.
Press the ON button to start the laser again. The inclined laser plane on the
Y-axis stays. In this case it is necessary to check if the alignment and
inclinations are still correct.