Standby Mode
Pressing “Warm” or “Cool” then “Jets 2” will turn
off all spa functions temporarily. This is helpful
when changing a filter. Press any button to exit
Standby mode.
Jets 1
Press the “Jets 1” button once to turn pump 1 on,
again to switch to high-speed. Pressing for a third
time turns pump 1 off. If left running, the low
speed turns off after 2 hours and the high speed
turns off after 15 minutes.
The low-speed of pump 1 runs when the blower or
any other pump is on. It may also activate for at
least 2 minutes every 30 minutes to detect the spa
temperature (polling) and then to heat to the set
temperature if needed, depending upon mode.
When the low speed turns on automatically, it
cannot be deactivated from the panel; however, the
high speed may be started.
Jets 2
Press the “Jets 2” button once to turn pump 2 on to
high-speed. Pressing once more, turns off pump 2.
If left running, the pump will turn off after 15
minutes.
Blower
Press the “Blower” button to turn on, twice to turn
on low speed, three times to turn on medium speed
and a fourth time to turn on high-speed. Pressing
once more will turn the blower off.
If left on, the blower will automatically turn off
after 15 minutes.
Light
Press the “Light” button to turn the spa light on
and off. Will also control optional LED lighting.
Preset Filter Cycles
On all systems, the pump and the ozone generator
will run during filtration. At the start of each filter
cycle, the blower will run on highest speed for 30
seconds to clean out the air channels. The low-
speed of pump 2 will run for 5 minutes.
There are two filter cycles per day. The start/end
times of each cycle are programmable. To
program, set time as instructed above, then press
“Mode/Prog” to advance to the next setting (or to
exit after the last setting). The default filter cycles
are as follows:
The first filter cycle is automatically activated at
8:00 AM and operates the pump until 10:00 AM.
The filter 1 indicator icon will light when filter 1 is
running.
The second filter cycle is automatically activated
at 8:00 PM and operates the pump until 10:00 PM.
The filter 2 indicator icon will light when filter 2 is
running.
Optional Filter Cycle Programming
You are not required to set filter cycles; however,
it is an option available to you. To change the filter
cycle settings:
Press “Time” “Mode/Prog” “Mode/Prog”
“Mode/Prog” within 3 seconds. You will see the
“SET FILTER 1” and a flashing “START TIME”
icon appear on the display.
Press “Up” or “Down” to choose the filter start
time hour. Enter the hour by pressing
“Mode/Prog”. Press “Up” or “Down” to choose the
filter start time minutes. Each press changes the
start time by 5 minutes.
Enter the minutes by pressing “Mode/Prog.”
Press “Mode/Prog” to see the “SET FILTER 1”
and a flashing “END TIME” icon. Adjust the time
as done above.
Press “Mode/Prog” to see the “SET FILTER 2”
(PM cycle) and a flashing “START TIME” icon.
Proceed as above.
Press “Mode/Prog” to see “SET FILTER 2” and a
flashing “END TIME” icon. Adjust the time as
done above.
Pressing “Mode/Prog” will enter the new filter
cycle times into the system and display the current
water temperature.
Pressing “Time” at any time during this
programming sequence will save the values
entered up to that point and exit programming.
If you would like to select continuous filtration, set
the filter 1 start and end times to be the exact same
time.
Clean-up Cycle
When the pump or blower is turned on by a button
press, a clean-up cycle begins 30 minutes after the
pump or blower is turned off or times out. The
pump and the ozone generator** will run for one
hour.
Freeze Protection
If the temperature sensors detect a drop to 44° F
(approximately 6.7° C) within the heater, then the
pump automatically activates to provide freeze
protection. The equipment stays on until 4 minutes
after the sensors detect that the spa temperature has
risen to 45° F (approximately 7.2°C) or higher. In
colder climates, an optional additional freeze
sensor may be added to protect against freeze
conditions that may no be sensed by the standard
sensors. Aux freeze sensor protection acts
similarly except t\with the temperature thresholds
determined by the switch and without a 4-minute
delay in turnoff. See you dealer for details.
Locking the Panel
Press “Time” Jets 1” then the “Warm” with in 3
seconds. When locked the PL indicator light will
light. All buttons are frozen except the “Time”
button. To unlock panel, press “Time” “Jets 1”
then “Cool.”