27
Electrical Connection Overview
2
Internal Connectors and Ports
1
2
4
5
3
6
8
7
9
1
Load
6
DRM
2
Grid
7
LAN
3
Ext. comm. 2
8
RS-485
4
Ext. comm. 1
9
Battery for Dark Start
5
Ext. CT
Note
For information about how to open the covers, see "7 Opening the Covers" on page 29.
6.2 Power Cable Specification
The power cables must correspond to the AC/DC input and output specifications for this product.
Cables are not included in the product package.
Cable
Diameter
Nominal Voltage
Color
EU (DE, FR) and GB
AU
Grid (L, N, PE)
6 mm
2
600 V or more
L
: Brown or Black
N
: Blue
PE
: Green / Yellow
L
: Brown or Red
N
: Blue or Black
PE
: Green / Yellow or Green
Load (L, N, PE)
6 mm
2
600 V or more
PV+, PV−
4 to 6 mm
2
600 V or more
-
Battery DC
6 mm
2
400 V or more
Recommend
DC+
: RED,
DC−
: Black,
PE:
Green / Yellow or Green