background image

INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.MAXX-G4

INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.MAXX-G4

4

5

1 Introduction

Validity

These instructions are only valid for crystalline solar modules 
from the company Qcells as specified at chapter "2.1 Technical 
specifications"
. Qcells assumes no liability for damage resulting 
from failure to observe these instructions.

  Please observe the wiring and dimensioning of the system.
  The installer of the system is responsible for compliance with 

all necessary safety regulations during set-up and installation.

Qcells assumes no liability on the basis of these instructions. 
Qcells is only liable in the context of contractual agreements or 
in the context of accepted guarantees. Qcells accepts no other 
responsibility for the functionality and safety of the modules.

  Please observe the instructions for any other system 

components that may be part of the complete solar power 
system. It may be necessary to carry out a structural analysis 
for the entire project.

Additional information for the Operator

  Please keep this manual for the entire life of the solar power 

system.

  Please contact your system supplier for information concerning 

the formal requirements for solar power systems.

  Please be sure to contact the relevant local authorities 

and energy providers regarding regulations and permit 
requirements prior to installation of the solar power system.

Other applicable documents

In addition to this Manual following technical information are 
relevant:

Document type

Product data sheet

Packaging and transport information

 
MISUSE OR INCORRECT USE OF SOLAR MODULES VOIDS 
THE LIMITED WARRANTY AND MAY CREATE A SAFETY 
HAZARD AND RISK PROPERTY DAMAGE. THIS INCLUDES 
IMPROPER INSTALLATION OR CONFIGURATION, IMPROPER 
MAINTENANCE, UNINTENDED USE, AND UNAUTHORIZED 
MODIFICATION.

2 Planning

2.1 Technical specifications

For additional information see the relevant datasheet of the module provided at www.qcells.com/au/.

PRODUCT LINE

Q.MAXX-G4, Q.MAXX-G4+

Q.MAXX BLK-G4, Q.MAXX BLK-G4+

Type

Q.ANTUM DUO Z

Length

1692mm

Width

1134 mm

Frame height

32 mm

Area

1.92 m²

Weight

20.9 kg

Max. system voltage V

SYS

1000 V

Max. reverse current

25 A

Permissible temperature range

–40 °C to +85 °C (–40 °F to +185 °F)

Junction box protection class

IP67 with bypass diode

Connector protection class

IP68

Fire rating based on ANSI / UL 61730

C / Type 2

Max. test load Push / Pull

1

8,100 Pa / 4,000 Pa

Max. design load Push / Pull

1

5,400 Pa / 2,660 Pa

Certificates

CE-compliant; IEC 61215:2016; IEC 61730:2016; PV module classification: Class II;  
QCPV

1

 Test and design load in accordance with IEC 61215:2016, depending on mounting options (see section "2.3 Mounting options")

DETAIL A

16 mm

8.5 mm

24.5 mm

980 mm

1692 mm

4 × Mounting slots 
(DETAIL A)

Frame

32 mm

8 × Drainage holes

356 mm

4 × Grounding points ø 4.5 mm

Label

1134 mm

1020 mm

≥ 1250

 mm

≥ 1250

 mm

Fig. 1:

 External dimensions and components for Q.MAXX-G4, Q.MAXX-G4+, 

                                                                               Q.MAXX BLK-G4, Q.MAXX BLK-G4+

Attention!

This marking indicates that this product should not be disposed 
of with other household waste within the EU. Recycle this product 
properly to prevent possible damage to the environment or 
a risk to human health via uncontrolled waste disposal and in 
order to promote the sustainable reuse of material resources. 
Please return your used product to an appropriate collection 
point or contact the retailer where you purchased this product. 
Your retailer will accept used products and return them to an 
environmentally-sound recycling facility.

Summary of Contents for Q.MAXX-G4 Series

Page 1: ...Installation and operation manual Q MAXX G4 solar module series...

Page 2: ...le stipulations such as country specific regulations for pressure equipment operational safety hazardous goods and environmental protection Regulations and requirements specific to the system Any appl...

Page 3: ...TED WARRANTY AND MAY CREATE A SAFETY HAZARD AND RISK PROPERTY DAMAGE THIS INCLUDES IMPROPER INSTALLATION OR CONFIGURATION IMPROPER MAINTENANCE UNINTENDED USE AND UNAUTHORIZED MODIFICATION 2 Planning 2...

Page 4: ...structural requirements Compliant with local snow and wind loads Properly fastened to the ground the roof or the fa ade Forces acting on the module are relayed to the mounting substructure Ensures su...

Page 5: ...he system installer is responsible for the determination of location specific load requirements Ensure that the connection cables of the junction box do not run between laminate and mounting rails Mod...

Page 6: ...number of modules in the string Parallel Connection Modules may be damaged by the occurrence of reverse currents caused by module defects ground leaks or defective insulation Ensure that the maximum...

Page 7: ...es or junction box Carry modules upright and horizontally as shown Note Module damage may occur Never step on modules Do not subject modules to any mechanical stress Do not allow any objects to fall o...

Page 8: ...may result from the separation of a closed circuit These can result in life threatening injuries The danger increases when several modules are connected in series Please be aware of that the entire op...

Page 9: ...erformed by qualified and skilled personnel see page 3 Ensure correct polarity Use solar cables for the connection at the junction box outlet Only interconnect connectors of the same type and manufact...

Page 10: ...l Do not disconnect modules by yourself Please contact an installer or Qcells Technical Customer Service Department Dispose of modules in accordance with the local disposal regulations Ensure that all...

Page 11: ...Remove snow and ice carefully without force e g with a very soft broom Do not scratch off dirt Module cleaning has to be done by qualified personnel according to the state of the art and taking into a...

Page 12: ...cells Installation manual solar modules Q MAXX G4_2022 06_Rev03_AU HANWHA Q CELLS AUSTRALIA PTY LTD Suite 1 Level 1 15 Blue Street North Sydney NSW 2060 Australia EMAIL WEB TEL inquiry aus qcells com...

Reviews: